Permit Application Status

PRRES20215763


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215763
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
11/03/2021
11/05/2021
05/03/2022
11/17/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 11/05/2021
Right of Way Permit Fee $85.00 $85.00 Paid 11/05/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/05/2021
Valuation Fee New Single Family $1,032.85 $1,032.85 Paid 11/05/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 11/05/2021
Water Meter Fee $479.24 $479.24 Paid 11/05/2021
Not Ready Inspection Fee $75.00 $75.00 Paid 11/02/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/11/2022 01/11/2022
Misc
Informational
01/11/2022
Third Party inspection performed.
Underslab Plumbing Inspection - Residential Failed 1/11/2022 1/11/2022 01/11/2022
Misc
Corrective Action Required
01/11/2022
foundation back fill required to be able to view under slab plumbing for inspection. Mitchell Schwarz 01/11/2022 10:32 AM
Sewer Service Inspection - R Passed 1/12/2022 01/12/2022
Water Service Inspection - R Passed 1/14/2022 (10:45) 1/14/2022 01/14/2022
Erosion Control Inspection Residential Failed 1/14/2022 01/14/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/14/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 1/18/2022 1/18/2022 01/18/2022
Misc
Resolved
01/18/2022
foundation back fill required to be able to view under slab plumbing for inspection. Mitchell Schwarz 01/11/2022 10:32 AM
Gas Service Inspection - Residential Passed 6/16/2022 6/16/2022 06/16/2022
Electrical Service Inspection Passed 6/16/2022 6/16/2022 06/16/2022
All Rough Inspection - Residential Failed 6/16/2022 6/16/2022 06/16/2022
Misc
Corrective Action Required
06/16/2022
-address roofing panels not installed to manufactures specifications -anchor bolts to be within middle 1/3 of sill plate -protect nm within 6’ of attic access -stud packs for gt bearing points in garage -solid block sheathing breaks throughout garage -fire block laundry wall in garage -seal top plate penetration W garage wall -hold downs at gt truss -stud shoe for hole drill to close to edge for SE cable -missing stud owners entry -fire block hvac chase at laundry -address over bored stud laundry/garage -missing hold how’s for trusses though out -blocking at sheathing breaks master bath -properly install lib bracing bath 2 -front entry wall top plate not tied to bed 3 and garage wall -missing lateral bracing for trusses throughout -cspf basement windows to plans and design
All Rough Inspection - Residential Failed 6/29/2022 6/29/2022 06/29/2022
Misc
Corrective Action Required
06/16/2022
No further inspections until gravel filter is in compliance -fire block laundry /garage wall to furr down -stud shoe for hole drill to close to edge for SE cable -cspf basement windows to plans and design
Erosion Control Inspection Residential Failed 6/29/2022 06/29/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/29/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/29/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. maintain gravel filter
All Rough Inspection - Residential Not Ready 7/1/2022 7/1/2022 07/01/2022
Misc
Corrective Action Required
06/29/2022
No further inspections until gravel filter is in compliance -fire block laundry /garage wall to furr down -stud shoe for hole drill to close to edge for SE cable -cspf basement windows to plans and design Inspection denied no gravel filter Mitchell Schwarz 07/01/2022 9:54 AM
Corrective Action Required
07/01/2022
All Rough Inspection - Residential Passed 7/11/2022 7/11/2022 07/11/2022
Misc
Resolved
07/11/2022
-cspf basement windows to plans and design okay to insulate
Driveway Inspection Passed 7/14/2022 7/14/2022 07/14/2022
Misc
Informational
07/14/2022
On Thursday, 7-14-2022. I performed and passed a driveway inspection for placement of concrete.
Sidewalk Inspection Passed 7/14/2022 7/14/2022 07/14/2022
Misc
Informational
07/14/2022
On Thursday, 7-14-2022. I performed and passed a sidewalk inspection for placement of concrete.
Plot Plan Inspection Passed 8/11/2022 08/11/2022
Piers/Caissons Inspection - Residential Passed 11/2/2022 11/02/2022
Erosion Control Inspection Residential Passed 11/2/2022 11/02/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
11/02/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. maintain gravel filter
Occupancy Inspection - Codes Residential Failed 11/2/2022 11/2/2022 11/02/2022
Misc
Corrective Action Required
11/02/2022
-pay all fees -splash blocks and sump pump discharge to extend 36” from foundation -stairs at front patio greater than 3/8” difference -rock bottom of furr out in garage -afci protection for dining room -spark rings as required see above fire place and check kitchen outlets
Occupancy Inspection - Codes Residential Full C of O 11/17/2022 11/17/2022 11/17/2022
Misc
Resolved
11/17/2022
-stairs at front patio greater than 3/8” difference -rock bottom of furr out in garage -afci protection for dining room -spark rings as required see above fire place and check kitchen outlets
Documents & Images
Date Uploaded File Type Document Name
11/03/2021 H4 #132 - PERMIT APPLICATION
11/04/2021 Approved Plans approved plans
11/04/2021 Approved Plans APPROVED TRUSS LAYOUT
11/04/2021 Approved Plans APPROVED TRUSS PACKAGE
11/04/2021 Permit Codes Residential Plan Review
11/04/2021 SKM_C36821110414530
11/04/2021 Permit Codes Residential Plan Review
11/05/2021 Permit DS Building Permit
11/05/2021 Receipt Receipt for transaction:2021-008526
11/09/2021 Plot Plan APPROVED PLOT PLAN
12/13/2021 132 Hawthorne Ridge FTNG
01/11/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/14/2022 Letter INSPECTION SUMMARY
01/14/2022 Letter INSPECTION SUMMARY
01/14/2022 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter Codes 140 Day Letter
06/16/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
06/23/2022 132 Hawthorne Ridge Letter
06/23/2022 HT 132 Letter sheathing and over bore
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
08/10/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
11/02/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter INSPECTION SUMMARY
11/02/2022 Receipt Receipt for transaction:2022-008678
11/17/2022 Letter Codes Final Certificate of Occupancy
11/17/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home