Permit Application Status

PRRES20215592


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215592
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED PATIO - STOP WORK ORDER generated on 12/07/2021 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 12/20/2021 12:00 AM by username 'Mitchell Schwarz'.
10/25/2021
10/27/2021
10/04/2022
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
Curtis Tate, Address:PO box 942   
TEAGUE ELECTRIC CONSTRUCTION INC, Address:12425 W 92ND ST, Phone:(913) 529-4600  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
CURTIS@SABHOMES.COM  
Brandon Bamesberger, Address:PO Box 942  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 10/27/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/27/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/27/2021
9110078-Valuation Fee New Single Family $983.28 $983.28 Paid 10/27/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/27/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/27/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/09/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/09/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/09/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 10/03/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 11/24/2021 11/24/2021
Misc
Corrective Action Required
11/24/2021
-ufer not located where 3rd party inspection indicates.
Sewer Service Inspection - R Passed 11/30/2021 (8:00) 11/30/2021 11/30/2021
Water Service Inspection - R Passed 12/1/2021 (10:30) 12/1/2021 12/01/2021
Erosion Control Inspection Residential Failed 12/1/2021 12/01/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/01/2021
REPAIR DOWNED SILT FENCE. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Failed 12/7/2021 12/7/2021 12/07/2021
Misc
Corrective Action Required
12/07/2021
Provide proper venting for basement bathroom see code section P3108.2.1 Horizontal wet vent
Footing Inspection - Residential Failed - Stop Work 12/7/2021 12/07/2021
Misc
Corrective Action Required
11/24/2021
-address ufer not located where 3rd party inspection indicates.
Footing Inspection - Residential Passed 12/20/2021 12/20/2021
Misc
Resolved
12/20/2021
-address ufer not located where 3rd party inspection indicates.
Misc
Informational
12/20/2021
3RD party footing inspection (revised)
Underslab Plumbing Inspection - Residential Passed 12/21/2021 12/21/2021 12/21/2021
Misc
Resolved
12/21/2021
Provide proper venting for basement bathroom see code section P3108.2.1 Horizontal wet vent
Electrical Service Inspection Passed 4/8/2022 4/8/2022 04/08/2022
All Rough Inspection - Residential Failed 4/8/2022 4/8/2022 04/08/2022
Misc
Corrective Action Required
04/08/2022
- Nail exterior corners to code through out - Unable to see PFH nail pattern on portal frame , nail pattern not done at bottom 3’ please expose at least one side - Ridge not supported by load bearing wall master suite at tub - Add stud under double 6” lvl at kitchen - 16” double lvl at stairs require a 4 stud pack - Provide support from rotation in double 16” LVL in great room - Add studs both ends of double lvl at fire place per plan - Fire block chase top plate at Bvent - Fire block end of soffit at basement stairs landing - Finish solid blocking fire block basement top plate bathroom sink - Additional support needed at basement chase wider than 4’ bedroom 4 - Fire block top plate at egress window basement bedroom 4 - Fire block top plate bedroom 3 basement - Plans call for 3 1/2” steel columns basement family room at long I beam
Gas Service Inspection - Residential Passed 4/8/2022 4/8/2022 04/08/2022
All Rough Inspection - Residential Failed 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/08/2022
- Nail exterior corners to code through out - Plans call for 3 1/2” steel columns basement family room at long I beam
All Rough Inspection - Residential Not Ready 4/14/2022 4/14/2022 04/14/2022
Misc
Corrective Action Required
04/12/2022
- Nail exterior corners to code through out (Could not inspect already insulated)
All Rough Inspection - Residential Not Ready 4/18/2022 4/18/2022 04/18/2022
Misc
Corrective Action Required
04/14/2022
- Nail exterior corners to code through out (Could not inspect already insulated) multiple areas still not nailed Mitchell Schwarz 04/18/2022 8:55 AM
All Rough Inspection - Residential Passed 4/19/2022 4/19/2022 04/19/2022
Misc
Resolved
04/19/2022
- Nail exterior corners to code through out (Could not inspect already insulated) multiple areas still not nailed Mitchell Schwarz 04/18/2022 8:55 AM
Driveway Inspection Partial 7/19/2022 7/19/2022 07/19/2022
Misc
Informational
07/19/2022
On 7.19.2022 i conducted a driveway inspection and pass the subgrade to pour concrete.
Sidewalk Inspection Partial 7/19/2022 7/19/2022 07/19/2022
Misc
Informational
07/19/2022
On 7.19.2022 i conducted a sidewalk inspection and pass the subgrade to pour concrete.
Piers/Caissons Inspection - Residential Passed 8/3/2022 08/03/2022
Occupancy Inspection - Codes Residential Failed 8/3/2022 8/3/2022 08/03/2022
Misc
Corrective Action Required
08/03/2022
-address pending driveway and sidewalk inspection -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of final grade and sod -illuminate address -complete rear patio stairs -guard rail at back patio where required by code -Ladders for egress window wells -tamper caps at A/c unit -rock under furr outs in garage
Occupancy Inspection - Codes Residential Ready for Temp CO 8/5/2022 8/5/2022 08/05/2022
Misc
Corrective Action Required
08/03/2022
TCO 9/5/22 -address pending driveway and sidewalk inspection -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of final grade and sod -illuminate address -guard rail at back patio where required by code -tamper caps at A/c unit
Driveway Inspection Passed 8/8/2022 08/08/2022
Misc
Informational
07/19/2022
On 7.19.2022 i conducted a driveway inspection and pass the subgrade to pour concrete. 8.8.2022 Driveway appears to be compliant
Sidewalk Inspection Passed 8/8/2022 08/08/2022
Misc
Informational
07/19/2022
On 7.19.2022 i conducted a sidewalk inspection and pass the subgrade to pour concrete. 8.8.2022 Sidewalk appears to be compliant
Occupancy Inspection - Codes Residential Temporary C of O 08/09/2022
Misc
Corrective Action Required
08/05/2022
TCO 9/5/22 -address pending driveway and sidewalk inspection -final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -check water meter at time of final grade and sod -illuminate address -guard rail at back patio where required by code -tamper caps at A/c unit
Occupancy Inspection - Codes Residential Failed 9/6/2022 9/6/2022 09/06/2022
Misc
Corrective Action Required
08/09/2022
TCO 9/5/22 TCO EXPIRED, SUBMIT TCO EXTENSION REQUEST FORM -remove sidewalk -complete final grade and sod after sidewalk removal -tamper caps at A/c unit
Occupancy Inspection - Codes Residential Ready for Temp CO 9/8/2022 09/08/2022
Misc
Corrective Action Required
09/06/2022
-pay TCO Extension Fee -remove sidewalk -complete final grade and sod after sidewalk removal -tamper caps at A/c unit
Occupancy Inspection - Codes Residential Temporary C of O 10/3/2022 10/3/2022 10/03/2022
Misc
Corrective Action Required
09/08/2022
-pay TCO Extension Fee -remove sidewalk -complete final grade and sod after sidewalk removal -tamper caps at A/c unit
Plot Plan Inspection Passed 10/4/2022 10/04/2022
Erosion Control Inspection Residential Passed 10/4/2022 10/04/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/04/2022
REPAIR DOWNED SILT FENCE. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS IN COMPLIANCE.
Occupancy Inspection - Codes Residential Full C of O 10/4/2022 10/4/2022 10/04/2022
Misc
Resolved
10/04/2022
-pay TCO Extension Fee -remove sidewalk -complete final grade and sod after sidewalk removal -tamper caps at A/c unit
Documents & Images
Date Uploaded File Type Document Name
10/25/2021 HF012 - Air Combustion
10/25/2021 hf12 excise tax app
10/25/2021 hf12 permit app
10/26/2021 Approved Plans approved plans
10/26/2021 Plot Plan APPROVED PLOT PLAN
10/27/2021 Permit Codes Residential Plan Review
10/27/2021 Permit DS Building Permit
10/27/2021 Receipt Receipt for transaction:2021-008275
11/23/2021 M L Crose 2035 SW Farm Field Ln LSMO Hook Farms Lot 12 SAB Permit 2021-5592 Foundation footing Inspection Report 11-4-21
11/24/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
12/01/2021 Letter INSPECTION SUMMARY
12/01/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter INSPECTION SUMMARY
12/07/2021 Letter Stop Work Order
12/20/2021 M L Crose 2035 SW Farm Field Ln LSMO Hook Farms Lot 12 SAB Permit 2021-5592 Foundation footing Inspection Report Revised 12-20-21
12/20/2021 Letter Stop Work Order
12/20/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
01/10/2022 Final_2021_12_23_DPiers_LSMO_Pat Cochran Concrete
04/08/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter INSPECTION SUMMARY
04/18/2022 Letter INSPECTION SUMMARY
04/19/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
08/03/2022 Letter INSPECTION SUMMARY
08/03/2022 Letter INSPECTION SUMMARY
08/09/2022 Receipt Receipt for transaction:2022-006530
08/09/2022 Letter Codes Temporary Certificate of Occupancy
09/06/2022 Letter INSPECTION SUMMARY
09/08/2022 Activity Document 2035 SW Farm Field Ln Extension request
10/03/2022 Receipt Receipt for transaction:2022-007956
10/03/2022 Certificate/License Codes Temporary Certificate of Occupancy
10/04/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter Field Certificate of Occupancy
10/04/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home