Permit Application Status

PRRES20215236


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215236
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 12/13/2021 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 12/14/2021 12:00 AM by username 'Patrick Schonfeldt'.
10/07/2021
10/18/2021
02/23/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 10/18/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 10/18/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/18/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/18/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/18/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/18/2021
9110078-Valuation Fee New Single Family $1,510.75 $1,510.75 Paid 10/18/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 08/08/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/19/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/19/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 01/19/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 12/13/2021 12/13/2021 12/13/2021
Misc
Corrective Action Required
12/13/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION.
Footing Inspection - Residential Failed - Stop Work 12/13/2021 12/13/2021
Misc
Corrective Action Required
12/13/2021
ADDRESS FOOTING POURED WITHOUT INSPECTION
Footing Inspection - Residential Passed 12/14/2021 12/14/2021 12/14/2021
Misc
Informational
12/14/2021
APPROVED PER BRADLEY HUXOL 10/26/21
Underslab Plumbing Inspection - Residential Passed 12/15/2021 12/15/2021 12/15/2021
Misc
Resolved
12/15/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION.
Sewer Service Inspection - R Passed 1/3/2022 (1:00) 1/3/2022 01/03/2022
Water Service Inspection - R Passed 1/5/2022 (8:00) 1/5/2022 01/05/2022
Erosion Control Inspection Residential Failed 1/27/2022 01/27/2022
Misc
Corrective Action Required
01/27/2022
-erosion control not in compliance -clean up street - REMOVE TRUSSES AND LUMBER FROM STREET
Erosion Control Inspection Residential Failed 3/8/2022 3/8/2022 03/08/2022
Misc
Resolved
03/08/2022
-erosion control not in compliance -clean up street - REMOVE TRUSSES AND LUMBER FROM STREET
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/08/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. ADDRESS EROSION CONTROL ON LOT GRAVEL FILTER REQUIRED, MIN 6" LIFT 3/4" GRAVEL CLEAN ALL MUD FROM STREET
All Rough Inspection - Residential Not Ready 7/19/2022 7/19/2022 07/19/2022
Misc
Corrective Action Required
07/19/2022
INSPECTION DENIED NOT READY FOR INSPECTION, TOO MANY DEFICIENCIES
Electrical Service Inspection Failed 7/19/2022 7/19/2022 07/19/2022
Misc
Corrective Action Required
07/19/2022
INSPECTION DENIED NOT READY FOR INSPECTION, TOO MANY DEFICIENCIES
Gas Service Inspection - Residential Failed 7/19/2022 7/19/2022 07/19/2022
Misc
Corrective Action Required
07/19/2022
INSPECTION DENIED NOT READY FOR INSPECTION, TOO MANY DEFICIENCIES
All Rough Inspection - Residential Not Ready 8/8/2022 8/8/2022 08/08/2022
Misc
Corrective Action Required
07/19/2022
INSPECTION DENIED NOT READY FOR INSPECTION, MISSING JOIST HANGERS, BROKEN TRUSSES NO ENGINEER LETTER RECEIVED, COMPLETE ALL FIREBLOCKING, FUR OUTS AT HVAC GARAGE WALL, GARAGE PORTAL TENSION STRAPS, TRADES WORKING AT TIME OF INSPECTION, ETC. THESE SAME ISSUES DISSCUSSED DURING LAST INSPECTION 7/19/22 AND HAVENT BEEN RESOLVED ROCK HAS BEEN DELIVERED TO HOUSE AND IS STAGED ALONG WALLS, MOVE ALL STACKS OF ROCK OFF WALLS AND STACK IN CENTER OF ROOM SO INSPECTION CAN BE PERFORMED BEFORE RESCHEDULING
Electrical Service Inspection Failed 8/8/2022 8/8/2022 08/08/2022
Misc
Corrective Action Required
07/19/2022
INSPECTION DENIED NOT READY FOR INSPECTION, MISSING JOIST HANGERS, BROKEN TRUSSES NO ENGINEER LETTER RECEIVED, COMPLETE ALL FIREBLOCKING, FUR OUTS AT HVAC GARAGE WALL, GARAGE PORTAL TENSION STRAPS, TRADES WORKING AT TIME OF INSPECTION, ETC. THESE SAME ISSUES DISSCUSSED DURING LAST INSPECTION 7/19/22 AND HAVENT BEEN RESOLVED ROCK HAS BEEN DELIVERED TO HOUSE AND IS STAGED ALONG WALLS, MOVE ALL STACKS OF ROCK OFF WALLS AND STACK IN CENTER OF ROOM SO INSPECTION CAN BE PERFORMED BEFORE RESCHEDULING
Gas Service Inspection - Residential Failed 8/8/2022 8/8/2022 08/08/2022
Misc
Corrective Action Required
07/19/2022
INSPECTION DENIED NOT READY FOR INSPECTION, MISSING JOIST HANGERS, BROKEN TRUSSES NO ENGINEER LETTER RECEIVED, COMPLETE ALL FIREBLOCKING, FUR OUTS AT HVAC GARAGE WALL, GARAGE PORTAL TENSION STRAPS, TRADES WORKING AT TIME OF INSPECTION, ETC. THESE SAME ISSUES DISSCUSSED DURING LAST INSPECTION 7/19/22 AND HAVENT BEEN RESOLVED ROCK HAS BEEN DELIVERED TO HOUSE AND IS STAGED ALONG WALLS, MOVE ALL STACKS OF ROCK OFF WALLS AND STACK IN CENTER OF ROOM SO INSPECTION CAN BE PERFORMED BEFORE RESCHEDULING
Electrical Service Inspection Passed 8/11/2022 08/11/2022
Misc
Resolved
08/11/2022
INSPECTION DENIED NOT READY FOR INSPECTION, MISSING JOIST HANGERS, BROKEN TRUSSES NO ENGINEER LETTER RECEIVED, COMPLETE ALL FIREBLOCKING, FUR OUTS AT HVAC GARAGE WALL, GARAGE PORTAL TENSION STRAPS, TRADES WORKING AT TIME OF INSPECTION, ETC. THESE SAME ISSUES DISSCUSSED DURING LAST INSPECTION 7/19/22 AND HAVENT BEEN RESOLVED ROCK HAS BEEN DELIVERED TO HOUSE AND IS STAGED ALONG WALLS, MOVE ALL STACKS OF ROCK OFF WALLS AND STACK IN CENTER OF ROOM SO INSPECTION CAN BE PERFORMED BEFORE RESCHEDULING
Gas Service Inspection - Residential Passed 8/11/2022 08/11/2022
Misc
Resolved
08/11/2022
INSPECTION DENIED NOT READY FOR INSPECTION, MISSING JOIST HANGERS, BROKEN TRUSSES NO ENGINEER LETTER RECEIVED, COMPLETE ALL FIREBLOCKING, FUR OUTS AT HVAC GARAGE WALL, GARAGE PORTAL TENSION STRAPS, TRADES WORKING AT TIME OF INSPECTION, ETC. THESE SAME ISSUES DISSCUSSED DURING LAST INSPECTION 7/19/22 AND HAVENT BEEN RESOLVED ROCK HAS BEEN DELIVERED TO HOUSE AND IS STAGED ALONG WALLS, MOVE ALL STACKS OF ROCK OFF WALLS AND STACK IN CENTER OF ROOM SO INSPECTION CAN BE PERFORMED BEFORE RESCHEDULING
All Rough Inspection - Residential Failed 8/11/2022 8/11/2022 08/11/2022
Misc
Corrective Action Required
08/08/2022
-address over notched joist above garage SE corner -fireblock furr outs into furr down in garage -fire block garage S wall into furr down see owners entry, hvac chase, dead space -tie bath 4 exterior wall to garage exterior wall -fire block bath 4 wall into bed 5 furr down -properly secure and support NM in furr down -fire block bed 5 W wall into furr down -nail truss fixes above bed 5 per manufacture specifications -complete panning in furr down for return air above fridge -address hvac above kitchen/dining area not complete. Also N dining hvac area(Areas blocked off that shouldn’t be, panning in furr down not done, penetrations in studs and joist spaces not sealed) -address multiple joist above great room over notched or too close to edge -secure gas line at fireplace -move sheet rock for 2nd floor inspection -secure water line in basement -steel columns in basement in correct size -fireblock vertical to horizontal every 10’ at basement stairwell -will check all trusses at time of re inspection and access to 2nd floor
Driveway Inspection Partial 8/15/2022 08/15/2022
Misc
Informational
08/15/2022
8.15.2022 I performed a driveway inspection and pass the subgrade to pour concrete
All Rough Inspection - Residential Not Ready 8/17/2022 8/17/2022 08/17/2022
Misc
Corrective Action Required
08/17/2022
-fireblock furr outs into furr down in garage -fire block garage S wall into furr down see owners entry, hvac chase, dead space -tie bath 4 exterior wall top plate to garage exterior wall top plate -fire block bath 4 wall into bed 5 furr down -properly secure and support NM in furr down -fire block bed 5 W wall into furr down missing areas -nail truss fixes above bed 5 per manufacture specifications -complete panning in furr down for return air above fridge -address hvac above kitchen/dining area not complete. Also N dining hvac area(Areas blocked off that shouldn’t be, panning in furr down not done, penetrations in studs and joist spaces not sealed) return air may only be used for one floor per chase -address multiple joist above great room over notched or too close to edge fix to engineer specifications - secure gas line at fireplace -complete hvac in 2nd floor attic space -missing hold down for double gt truss above front entry -incorrect hanger on D7 -steel columns in basement to be correct size -fireblock vertical to horizontal every 10’ at basement stairwell
Driveway Inspection Passed 8/19/2022 8/19/2022 08/18/2022
Misc
Informational
08/15/2022
8.15.2022 I performed a driveway inspection and pass the subgrade to pour concrete 8.18.2022 Driveway appears to be in compliance.
Sidewalk Inspection Partial 8/18/2022 8/18/2022 08/18/2022
Misc
Informational
08/18/2022
8.18.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete
All Rough Inspection - Residential Failed 8/23/2022 8/23/2022 08/23/2022
Misc
Corrective Action Required
08/17/2022
-fire block garage S wall into furr down see hvac chase -tie bath 4 exterior wall top plate to garage exterior wall top plate -nail truss fixes above bed 5 per manufacture specifications -seal all penetrations through air returns -Support HVAC flex duct 2nd floor attic -incorrect hanger on D7, LUS26 per plans -fireblock vertical to horizontal every 10’ at basement stairwell
Sidewalk Inspection Passed 8/25/2022 8/25/2022 08/25/2022
Misc
Informational
08/25/2022
8-25-22 RH. Sidewalk meets LS and ADA Specification.
Driveway Inspection Passed 8/25/2022 08/25/2022
Misc
Informational
08/25/2022
8-25-22 RH. Driveway meets LS and ADA Specification.
All Rough Inspection - Residential Passed 8/25/2022 8/25/2022 08/25/2022
Misc
Resolved
08/25/2022
Occupancy Inspection - Codes Residential Not Ready 12/19/2022 12/19/2022 12/19/2022
Misc
Corrective Action Required
12/19/2022
INSPECTION DENIED, NO ADDRESS POSTED
Piers/Caissons Inspection - Residential Passed 1/18/2023 01/18/2023
Plot Plan Inspection Passed 1/18/2023 01/18/2023
Erosion Control Inspection Residential Passed 1/18/2023 01/18/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
01/18/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. ADDRESS EROSION CONTROL ON LOT GRAVEL FILTER REQUIRED, MIN 6" LIFT 3/4" GRAVEL CLEAN ALL MUD FROM STREET
Occupancy Inspection - Codes Residential Failed 1/18/2023 1/18/2023 01/18/2023
Misc
Resolved
01/18/2023
INSPECTION DENIED, NO ADDRESS POSTED
Misc
Corrective Action Required
01/18/2023
-pay all fees -hardware at rear patio door -security screws at rear door -future vent for future basement bath -water meter to be 14”-18” from top of meter to well lid
Occupancy Inspection - Codes Residential Failed 01/18/2023
Misc
Corrective Action Required
01/18/2023
-pay all fees -hardware at rear patio door -security screws at rear door -future vent for future basement bath -water meter to be 14”-18” from top of meter to well lid -splash blocks and sump pump discharge to extend 36” from foundation
Occupancy Inspection - Codes Residential Full C of O 2/23/2023 2/23/2023 02/23/2023
Misc
Resolved
02/23/2023
-pay all fees -hardware at rear patio door -security screws at rear door -future vent for future basement bath -water meter to be 14”-18” from top of meter to well lid -splash blocks and sump pump discharge to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
10/07/2021 RR #70 - PERMIT APP
10/11/2021 Approved Plans approved plans
10/11/2021 Approved Plans APPROVED TRUSS LAYOUT
10/11/2021 Approved Plans APPROVED TRUSS PACKAGE
10/11/2021 Plot Plan APPROVED PLOT PLAN
10/11/2021 Permit Codes Residential Plan Review
10/11/2021 Permit Codes Residential Plan Review
10/18/2021 Permit DS Building Permit
10/18/2021 Receipt Receipt for transaction:2021-008040
12/13/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter Stop Work Order
12/13/2021 70 Reserve at Stoney Creek FTNG
12/13/2021 70 Reserve at Stoney Creek FDTN
12/14/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
01/03/2022 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
07/19/2022 Letter INSPECTION SUMMARY
08/08/2022 Receipt Receipt for transaction:2022-006479
08/08/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/09/2022 RR 70 Truss Letter
08/11/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
08/11/2022 Letter INSPECTION SUMMARY
08/16/2022 70 Reserve at Stoney Creek Letter 2
08/17/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/18/2022 Letter INSPECTION SUMMARY
08/23/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
08/25/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter INSPECTION SUMMARY
01/18/2023 Letter INSPECTION SUMMARY
01/18/2023 Letter INSPECTION SUMMARY
01/18/2023 Letter INSPECTION SUMMARY
01/18/2023 Letter INSPECTION SUMMARY
01/18/2023 Letter INSPECTION SUMMARY
01/19/2023 Receipt Receipt for transaction:2023-000345
02/23/2023 Letter Codes Final Certificate of Occupancy
02/23/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home