NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 05/23/2022 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 06/06/2022 12:00 AM by username 'Mitchell Schwarz'.
09/28/2021
10/27/2021
03/28/2022
10/27/2022
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
Jennifer Pestka, Address:p o box 6423  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
BSHELTON@IQHOMEBUILDERS.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,057.94 $1,057.94 Paid 10/27/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/27/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/27/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 10/27/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/27/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/27/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/27/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/29/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/30/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/27/2021 (10:45) 10/27/2021 10/27/2021
Underslab Plumbing Inspection - Residential Passed 12/30/2021 12/30/2021 12/30/2021
Sewer Service Inspection - R Passed 3/15/2022 (9:45) 3/15/2022 03/15/2022
Water Service Inspection - R Passed 3/16/2022 (9:15) 3/16/2022 03/16/2022
Erosion Control Inspection Residential Failed 3/29/2022 03/29/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/29/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 03/29/2022 11:23 AM
Piers/Caissons Inspection - Residential Failed 4/15/2022 04/15/2022
Misc
Corrective Action Required
04/15/2022
clean out bottom of middle pier
Erosion Control Inspection Residential Failed 4/15/2022 04/15/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
04/15/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 03/29/2022 11:23 AM
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/15/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. repair downed silt fence clean trash from lot
DCM5 ESC INSP DENIED
Corrective Action Required
04/20/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. erosion control still not in compliance from previous inspection -repair downed silt fence -clean up trash from lot -maintain gravel filter Mitchell Schwarz 04/20/2022 9:15 AM
Erosion Control Inspection Residential Failed 4/20/2022 04/20/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/15/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. repair downed silt fence clean trash from lot
DCM5 ESC INSP DENIED
Corrective Action Required
04/20/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. erosion control still not in compliance from previous inspection -repair downed silt fence -clean up trash from lot -maintain gravel filter Mitchell Schwarz 04/20/2022 9:15 AM
Electrical Service Inspection Failed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
inspection denied erosion control not in compliance
Gas Service Inspection - Residential Failed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
inspection denied erosion control not in compliance
All Rough Inspection - Residential Failed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
inspection denied due to erosion control
Erosion Control Inspection Residential Failed 4/28/2022 04/28/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/28/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. repair downed silt fence clean trash from lot
DCM5 ESC INSP DENIED
Resolved
04/28/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. erosion control still not in compliance from previous inspection -repair downed silt fence -clean up trash from lot -maintain gravel filter Mitchell Schwarz 04/20/2022 9:15 AM
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/28/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. maintain silt fence
Electrical Service Inspection Passed 4/28/2022 4/28/2022 04/28/2022
Misc
Resolved
04/28/2022
inspection denied erosion control not in compliance
Gas Service Inspection - Residential Passed 4/28/2022 4/28/2022 04/28/2022
Misc
Resolved
04/28/2022
inspection denied erosion control not in compliance
All Rough Inspection - Residential Failed 4/28/2022 4/28/2022 04/28/2022
Misc
Resolved
04/28/2022
inspection denied due to erosion control
Misc
Corrective Action Required
04/28/2022
-Uncover garage PFG for nailing inspection -anchor bolts at PFG to be per design -all anchor bolts shall be in the middle 1/3 of sill plate -address rafters landing in blocks -uncover covered patio for inspection -uncover s3.2 10 at deck for inspection -seal hole in floor in great room -hangers on joists above master entry -anchor bolts within 13” of plate breaks in basement no closer than 7x the bolt diameter to edge -anchor all steel columns in basement
All Rough Inspection - Residential Failed 5/6/2022 5/6/2022 05/06/2022
Misc
Corrective Action Required
04/28/2022
-Uncover garage PFG for nailing inspection -uncover covered patio for inspection -uncover s3.2 10 at deck for inspection
Erosion Control Inspection Residential Failed 5/18/2022 05/18/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/18/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. maintain silt fence
DCM5 ESC INSP DENIED
Corrective Action Required
05/18/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 05/18/2022 11:29 AM
All Rough Inspection - Residential Failed 5/18/2022 5/18/2022 05/18/2022
Misc
Corrective Action Required
05/06/2022
Inspection denied due to lack of erosion control. -Uncover garage PFG for nailing inspection -uncover covered patio for inspection -uncover s3.2 10 at deck for inspection
Erosion Control Inspection Residential Failed - Stop Work 5/23/2022 05/23/2022
DCM5 ESC INSP DENIED
Corrective Action Required
05/18/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/18/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 05/18/2022 11:29 AM
Misc
Corrective Action Required
05/23/2022
Erosion control still not in compliance Mitchell Schwarz 05/23/2022 11:34 AM
All Rough Inspection - Residential Not Ready 6/6/2022 6/6/2022 06/06/2022
Misc
Corrective Action Required
05/18/2022
-Uncover garage PFG for nailing inspection -uncover covered patio for inspection -uncover s3.2 10 at deck for inspection Okay to insulate
Erosion Control Inspection Residential Partial 6/6/2022 6/6/2022 06/06/2022
DCM5 ESC INSP DENIED
Resolved
06/06/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/06/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
06/06/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 05/18/2022 11:29 AM
Misc
Resolved
06/06/2022
Erosion control still not in compliance Mitchell Schwarz 05/23/2022 11:34 AM
Misc
Informational
06/06/2022
Erosion control back in compliance at time of inspection. Mitchell Schwarz 06/06/2022 9:02 AM
All Rough Inspection - Residential Passed 6/21/2022 6/21/2022 06/21/2022
Misc
Resolved
06/21/2022
Inspection denied due to lack of erosion control. -Uncover garage PFG for nailing inspection -uncover covered patio for inspection -uncover s3.2 10 at deck for inspection Okay to insulate
Piers/Caissons Inspection - Residential Partial 8/8/2022 (10:15) 8/8/2022 08/08/2022
Misc
Resolved
08/08/2022
clean out bottom of middle pier
Misc
Corrective Action Required
08/08/2022
South most pier needs sonotube
Driveway Inspection Partial 8/9/2022 8/9/2022 08/09/2022
Misc
Informational
08/09/2022
8.9.2022 I conducted a driveway inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 8/16/2022 (1:15) 8/16/2022 08/12/2022
Misc
Informational
08/09/2022
8.9.2022 I conducted a driveway inspection and pass the subgrade to pour concrete 8.12.2022 Driveway appears to be compliant
Occupancy Inspection - Codes Residential Not Ready 9/27/2022 9/27/2022 09/27/2022
Misc
Corrective Action Required
09/27/2022
inspection denied no erosiion control
Erosion Control Inspection Residential Failed 9/27/2022 09/27/2022
Misc
Resolved
09/27/2022
Erosion control back in compliance at time of inspection. Mitchell Schwarz 06/06/2022 9:02 AM
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/27/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Piers/Caissons Inspection - Residential Passed 9/28/2022 09/28/2022
Misc
Resolved
09/28/2022
South most pier needs sonotube
Plot Plan Inspection Passed 9/28/2022 09/28/2022
Erosion Control Inspection Residential Passed 9/28/2022 09/28/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/28/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 9/28/2022 9/28/2022 09/28/2022
Misc
Resolved
09/28/2022
inspection denied no erosiion control
Misc
Corrective Action Required
09/28/2022
-pay all fees -obtain lawn irrigation permit -gutters -splash block and sump pump discharge to extend 36” from foundation -landing at deck stairs to be completed and 36” in the direction of travel -stairs to basement greater that 3/8 difference in rise. See top step 6 1/2” others 7 1/2” -water heater relief valve discharge pipe not to code -complete landscaping at front and rear of lot
Occupancy Inspection - Codes Residential Ready for Temp CO 9/30/2022 9/30/2022 09/30/2022
Misc
Corrective Action Required
09/28/2022
-gutters -splash block and sump pump discharge to extend 36” from foundation -complete landscaping at front and rear of lot
Occupancy Inspection - Codes Residential Temporary C of O 9/30/2022 09/30/2022
Misc
Corrective Action Required
09/30/2022
-gutters -splash block and sump pump discharge to extend 36” from foundation -complete landscaping at front and rear of lot
Occupancy Inspection - Codes Residential Failed 10/18/2022 10/18/2022 10/18/2022
Misc
Corrective Action Required
09/30/2022
-splash block and sump pump discharge to extend 36” from foundation
Occupancy Inspection - Codes Residential Full C of O 10/27/2022 10/27/2022 10/27/2022
Misc
Resolved
10/27/2022
-splash block and sump pump discharge to extend 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
09/28/2021 Permit application
09/28/2021 license tax form
09/29/2021 Permit Codes Residential Plan Review
10/01/2021 Approved Plans Approved Drawings
10/05/2021 Plot Plan Approved Plot Plan
10/05/2021 Permit Codes Residential Plan Review
10/27/2021 Permit DS Building Permit
10/27/2021 Receipt Receipt for transaction:2021-008271
10/27/2021 Letter INSPECTION SUMMARY
12/30/2021 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/29/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
04/28/2022 Letter INSPECTION SUMMARY
05/04/2022 2614 SW Farmfield Road - Structural Letter
05/06/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/23/2022 Letter Stop Work Order
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/27/2022 Receipt Receipt for transaction:2022-005159
06/27/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/09/2022 30 am
08/09/2022 Letter INSPECTION SUMMARY
08/09/2022 Driveway subgrade 8_9_2022
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
09/07/2022 Plot Plan Approved As Graded Plot Plan
09/27/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
09/29/2022 Receipt Receipt for transaction:2022-007915
09/30/2022 Receipt Receipt for transaction:2022-007933
09/30/2022 Letter Codes Temporary Certificate of Occupancy
10/18/2022 Letter INSPECTION SUMMARY
10/27/2022 Letter Codes Final Certificate of Occupancy
10/27/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home