Permit Application Status

PRRES20215033


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215033
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
09/27/2021
10/27/2021
03/27/2022
05/05/2023
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
Jennifer Pestka, Address:p o box 6423  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
BSHELTON@IQHOMEBUILDERS.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,266.27 $1,266.27 Paid 10/27/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/27/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/27/2021
8331507-Sewer Connection Fee $570.00 $570.00 Paid 10/27/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 10/27/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 10/27/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/27/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 07/27/2022
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/4/2021 (10:30) 11/4/2021 11/04/2021
Underslab Plumbing Inspection - Residential Failed 11/19/2021 11/19/2021 11/19/2021
Misc
Corrective Action Required
11/19/2021
INSPECTION DENIED -NO ADDRESS -INSUFFICIENT EROSION CONTROL
Erosion Control Inspection Residential Failed 11/19/2021 11/19/2021
DCM5 ESC INSP DENIED
Corrective Action Required
11/19/2021
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Underslab Plumbing Inspection - Residential Not Ready 11/23/2021 11/23/2021 11/23/2021
Misc
Resolved
11/23/2021
INSPECTION DENIED -NO ADDRESS -INSUFFICIENT EROSION CONTROL
Misc
Corrective Action Required
11/23/2021
Foundation backfill required to view and inspect underslab plumbing
Underslab Plumbing Inspection - Residential Passed 11/30/2021 11/30/2021 11/30/2021
Misc
Corrective Action Required
11/23/2021
Erosion Control Inspection Residential Failed 3/16/2022 03/16/2022
DCM5 ESC INSP DENIED
Resolved
03/16/2022
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/16/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Repair downed silt fence
Piers/Caissons Inspection - Residential Passed 4/15/2022 04/15/2022
Electrical Service Inspection Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/21/2022
connect ufer ground to middle grounded bus bar.
Gas Service Inspection - Residential Passed 6/21/2022 6/21/2022 06/21/2022
All Rough Inspection - Residential Failed 6/21/2022 6/21/2022 06/21/2022
Misc
Corrective Action Required
06/21/2022
-anchor bolts at garage portal frame not in middle third and incorrect washer size -nail top plate to header per design at portal frame in garage -anchor bolts to be within 12” of plate breaks but not closer than 7x the diameter of the bolt -missing nails in hanger above garage entry into kitchen/breakfast -fireblock furr out wall for fridge frame ceiling line -address rear patio not framed to plans (uncover for further inspection) -address over notched stud for dwv at great room windows -secure gas line at fire place -adder holes drilled in floor joist closer than 2” at stairwell wall/great room -seal penetrations through hvac chase for NM wire -seal penetrations into ceiling space bed 2 -connect ufer ground to middle grounded bus bar -address holes drilled closer than 2” under kitchen island in basement
Electrical Service Inspection Passed 6/30/2022 6/30/2022 06/30/2022
Misc
Resolved
06/30/2022
connect ufer ground to middle grounded bus bar.
All Rough Inspection - Residential Failed 7/7/2022 7/7/2022 07/07/2022
Misc
Corrective Action Required
06/21/2022
-secure gas line at fire place OK to insulate
All Rough Inspection - Residential Not Ready 7/13/2022 7/13/2022 07/13/2022
Misc
Corrective Action Required
07/07/2022
-secure gas line at fire place not done OK to insulate
Erosion Control Inspection Residential Failed 7/13/2022 07/13/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
07/13/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Repair downed silt fence
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/13/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -MAINTAIN SILT FENCE AT FRONT OF LOT -MAINTAIN VEGETATION
All Rough Inspection - Residential Passed 7/15/2022 7/15/2022 07/15/2022
Misc
Resolved
07/15/2022
-secure gas line at fire place not done OK to insulate
Sewer Service Inspection - R Passed 8/5/2022 08/05/2022
Water Service Inspection - R Partial 8/8/2022 (1:30) 8/8/2022 08/08/2022
Misc
Informational
08/08/2022
pex ran from foundation
Water Service Inspection - R Passed 8/9/2022 (1:15) 8/9/2022 08/09/2022
Misc
Informational
08/08/2022
pex ran from foundation
Driveway Inspection Not Ready 9/21/2022 9/21/2022 09/21/2022
Misc
Informational
09/21/2022
9-21-22 RH. Aggregate was not compacted.
Driveway Inspection Partial 9/28/2022 9/28/2022 09/28/2022
Misc
Informational
09/21/2022
9-21-22 RH. Aggregate was not compacted. 9-28-22 RH. Driveway was formed up and aggregate was placed and compacted.
Driveway Inspection Passed 10/5/2022 10/5/2022 10/05/2022
Misc
Informational
09/28/2022
9-21-22 RH. Aggregate was not compacted. 9-28-22 RH. Driveway was formed up and aggregate was placed and compacted. 10-5-22 RH. Driveway meets LS specification.
Erosion Control Inspection Residential Failed 10/26/2022 10/26/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/26/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -MAINTAIN SILT FENCE AT FRONT OF LOT -MAINTAIN VEGETATION
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/26/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 10/26/2022 2:11 PM
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Mitchell Schwarz 10/26/2022 2:11 PM
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Plot Plan Inspection Passed 5/5/2023 05/05/2023
Erosion Control Inspection Residential Passed 5/5/2023 05/05/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Full C of O 5/5/2023 5/5/2023 05/05/2023
Documents & Images
Date Uploaded File Type Document Name
09/27/2021 2022 SW Hook Farm Dr - Tax App
09/27/2021 2022 SW Hook Farm Dr - Permit App
09/28/2021 Permit Codes Residential Plan Review
09/28/2021 Approved Plans Approved Drawings
09/28/2021 Plot Plan Approved Plot Plan
09/28/2021 Permit Codes Residential Plan Review
10/27/2021 Permit DS Building Permit
10/27/2021 Receipt Receipt for transaction:2021-008301
11/04/2021 Letter INSPECTION SUMMARY
11/19/2021 Letter INSPECTION SUMMARY
11/19/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/27/2022 Receipt Receipt for transaction:2022-005157
06/30/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/27/2022 Receipt Receipt for transaction:2022-006144
08/05/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/09/2022 Letter INSPECTION SUMMARY
09/21/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
10/05/2022 Letter INSPECTION SUMMARY
10/26/2022 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
05/05/2023 Letter INSPECTION SUMMARY
05/05/2023 Letter INSPECTION SUMMARY
05/05/2023 Letter Field Certificate of Occupancy
05/05/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home