Permit Application Status

PRRES20214945


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214945
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
09/21/2021
09/24/2021
03/22/2022
07/26/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 09/24/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/24/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 09/24/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 09/24/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 09/24/2021
9110078-Valuation Fee New Single Family $1,132.11 $1,132.11 Paid 09/24/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 12/22/2021 (11:30) 12/22/2021 12/22/2021
Miscellaneous Correction
Corrective Action Required
12/22/2021
UPLOAD DRILLED PIERS INSPECTION TO PERMIT POUR AT OWN RISK PENDING DRILLED PIER INSPECTION PROVIDE ADDRESS UFER LOCATED SOUTH WALL AT STEP DOWN
Piers/Caissons Inspection - Residential Passed 12/22/2021 12/22/2021
Misc
Informational
12/22/2021
3RD PARTY DRILLED PIERS BY BOB ROWE @ VAN DEURZEN AND ASSOCIATES SIGNED & SEALED BY CHAD STREETER 40 FOUNDATION & 3 DECK PIERS
Footing Inspection - Residential Passed 12/22/2021 12/22/2021
Miscellaneous Correction
Resolved
12/22/2021
PROVIDE ADDRESS UFER LOCATED SOUTH WALL AT STEP DOWN
Underslab Plumbing Inspection - Residential Passed 1/25/2022 1/25/2022 01/25/2022
Sewer Service Inspection - R Passed 3/15/2022 (1:15) 3/15/2022 03/15/2022
Water Service Inspection - R Passed 3/16/2022 3/16/2022 03/16/2022
All Rough Inspection - Residential Failed 12/21/2022 12/21/2022 12/21/2022
Miscellaneous Correction
Corrective Action Required
12/21/2022
- Connect gas to fire place - Secure CSST within 12” of appliance - Missing double stud pack at kitchen wall by gas - Nail exterior corners to plans throughout - Rafter in great room close to gable over double Lvl landing on air - Complete through bolts on I- beam in great room - LIB missing at kitchen wall - Missing joist hangers master closet - Provide joist hanger at triple LVL and entry - Anchor steel columns in basement - Provide solid blocking under island - Tighten plate bolts basement - Vertical Fb fur out in basement - basement bathroom vent ductwork to be 4”, 3” not allowed - Add 2x10” joist over bar per plans - Basement soffit wider than 4’ needs extra supports to joist - Nail exterior siding to code - Flashing and trim windows - Missing joists on deck - Provide (2) 1/2” through bolts at post to beam connections - Missing joist hanger at deck - Anchor deck ledger with approved methods
Electrical Service Inspection Passed 12/21/2022 12/21/2022 12/21/2022
Gas Service Inspection - Residential Passed 12/21/2022 12/21/2022 12/21/2022
Erosion Control Inspection Residential Failed 1/18/2023 01/18/2023
Misc
Corrective Action Required
01/18/2023
- REPAIR SILT FENCE
All Rough Inspection - Residential Passed 1/18/2023 1/18/2023 01/18/2023
Miscellaneous Correction
Resolved
01/18/2023
Driveway Inspection Partial 2/15/2023 2/15/2023 02/15/2023
Misc
Informational
02/15/2023
2-15-23 PS Driveway forms are in place and aggregate has been compacted, ok to pour
Driveway Inspection Passed 2/22/2023 2/22/2023 02/22/2023
Misc
Informational
02/15/2023
2-15-23 PS Driveway forms are in place and aggregate has been compacted, ok to pour 2-22-23 PS Driveway meets LS specifications
Plot Plan Inspection Passed 7/26/2023 07/26/2023
Occupancy Inspection - Codes Residential Full C of O 7/26/2023 7/26/2023 07/26/2023
Documents & Images
Date Uploaded File Type Document Name
09/21/2021 WR121_001
09/23/2021 Permit Codes Residential Plan Review
09/24/2021 Approved Plans approved plans
09/24/2021 Approved Plans APPROVED PLOT PLAN
09/24/2021 Permit Codes Residential Plan Review
09/24/2021 Permit DS Building Permit
09/24/2021 Receipt Receipt for transaction:2021-007580
12/22/2021 305 NW Ambersham Dr_PIER INSP_2021-12-14
12/22/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
12/22/2021 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter Codes 180 Day Letter
09/12/2022 Letter Codes 180 Day Letter
09/12/2022 Letter Codes 180 Day Letter
12/21/2022 Letter INSPECTION SUMMARY
12/21/2022 Letter INSPECTION SUMMARY
12/21/2022 Letter INSPECTION SUMMARY
01/18/2023 Letter INSPECTION SUMMARY
01/18/2023 Letter INSPECTION SUMMARY
02/15/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
06/19/2023 signed as built grading lot 121
06/20/2023 revised signed copy as built grading lot 121
06/21/2023 revised signed copy as built grading-2- lot 121
06/21/2023 Plot Plan approved as graded plot plan
07/26/2023 Letter INSPECTION SUMMARY
07/26/2023 Letter Field Certificate of Occupancy
07/26/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home