Permit Application Status

PRRES20214474


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214474
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINIHSED BASEMENT - COVERED DECK
08/26/2021
09/22/2021
09/26/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 09/22/2021
8331507-Sewer Connection Fee $450.00 $450.00 Paid 09/22/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/22/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 09/22/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 09/22/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 09/22/2021
9110078-Valuation Fee New Single Family $1,166.44 $1,166.44 Paid 09/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/14/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/14/2021 10/14/2021 10/14/2021
Misc
Informational
10/14/2021
APPROVED PER BRADLEY HUXOL 10/4/21
Erosion Control Inspection Residential Failed 10/14/2021 10/14/2021 10/14/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/14/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 10/27/2021 10/27/2021 10/27/2021
Erosion Control Inspection Residential Failed 10/27/2021 10/27/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/14/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/27/2021
STREET CLEAN UP REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Sewer Service Inspection - R Partial 3/28/2022 (8:15) 3/28/2022 03/28/2022
Misc
Corrective Action Required
03/28/2022
PARTIAL INSPECTION FROM HOUSE ENTRY APPROX 15' TOWARDS STREET
Water Service Inspection - R Partial 3/28/2022 3/28/2022 03/28/2022
Sewer Service Inspection - R Passed 4/4/2022 (10:15) 4/4/2022 04/04/2022
Misc
Resolved
04/04/2022
PARTIAL INSPECTION FROM HOUSE ENTRY APPROX 15' TOWARDS STREET
Water Service Inspection - R Passed 4/5/2022 (9:15) 4/5/2022 04/05/2022
Electrical Service Inspection Passed 5/3/2022 5/3/2022 05/03/2022
Gas Service Inspection - Residential Passed 5/3/2022 5/3/2022 05/03/2022
All Rough Inspection - Residential Failed 5/3/2022 5/3/2022 05/03/2022
Misc
Corrective Action Required
05/03/2022
-Maintain gravel filter on drive, address before rescheduling inspection -provide attic access above dbl car bay -protect NM within 6’ of attic entry -fireblock HVAC/plumbing chase at garage wall -replace the 2x4s at HVAC furred downs at garage ceiling with 2x6s, 2x4s not large enough for R-19 insulation -address top plate lap connection at ends steel beam garage walls, no connection with different wall heights -(3) studs required at wall corner connection, see single car bay garage west corner -provide (2) 2x4 stud pack at SE garage wall per plans -provide (4) 2x4 stud pack at (2) 9 1/4” lvl beam garage wall per plans, both locations at dbl and sgl car sides of garage -support DWV every 48” oc -provide stud shoe at exterior stud bored for DWV 1st floor powder bath -address floor joist that has been overnotched for DWV above pantry -provide 12” oc nailing at all abutting and intersecting wall corners -seal all penetrations through air returns -provide structural straps at all top plates bored 50% or more all interior load bearing walls and all exterior walls, strap min 1 1/2” wide, 16 gauge, must extend min 6” passed each side of opening with (4) 10D nails each side of strap -provide lateral restraint for dbl lvl beam for covered deck at great room box out -secure ward flex at fireplace -address top plate lap connection as required by code, see front entry closet 2x6 wall -seal all top plate penetrations, see above front entry, master bath -min 24” lap between top plate breaks, see covered deck, bed #1, basement -provide (4) 2x4 stud packs at W8x18 steel beam ends per plans dining room -solid shim all trimmer studs cut short of headers throughout -provide studs and plate at stair wall great room, right side of stairs -Have engineer address the gable truss SE garage wall, bottom cord of truss has been cut out for covered porch beam placement -provide H2.5 truss hold downs at covered deck above man door -provide full height studs at 2x6 stair wall East corner -address top plate lap corner connection required by code, see 2nd floor stair wall 2x6 to 2x4 wall front north bedroom -address top plate lap corner connections 2nd floor bed #2, both east and west corners of exterior wall -provide (4) 2X stud pack all girder truss ends per plans -address top plate lap corner connection see master bed closet and master bath -provide stud shoes at exterior studs bored for DWV master vanity -provide 30” vertical clearance at attic entry -6’8” head clearance required at basement stairs -provide studs to carry load to foundation wall between plates at basement stair wall -provide future vent for basement plumbing -nail all exterior sheathing per plans
Erosion Control Inspection Residential Failed 5/3/2022 05/03/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/03/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/03/2022
STREET CLEAN UP REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
05/03/2022
-Maintain gravel filter on drive, address before rescheduling inspection
All Rough Inspection - Residential Not Ready 5/17/2022 5/17/2022 05/17/2022
Misc
Corrective Action Required
05/03/2022
-replace the 2x4s at HVAC furred downs at garage ceiling with 2x6s, 2x4s not large enough for R-19 insulation-LOWER ELECTRICAL TO BE AT CEILING HEIGHT -address top plate lap connection at ends steel beam garage walls, no connection with different wall heights-LOWER WALLS NOT CONNECTED TO ANYTHING -support DWV every 48” oc -SEE POWDER ROOM -provide stud shoe at exterior stud bored for DWV 1st floor powder bath -USE PROPER FASTERS AND REPLACE DAMAGED STUD -address floor joist that has been overnotched for DWV above pantry-HAVE ENGINEER ADDRESS -Seal new through floor penetrations at kitchen -seal all penetrations through air returns-GAS LINES NOT ALLOWED IN RETURN SPACE -provide structural straps at all top plates bored 50% or more all interior load bearing walls and all exterior walls, strap min 1 1/2” wide, 16 gauge, must extend min 6” passed each side of opening with (4) 10D nails each side of strap-SEE KITCHEN -address top plate lap connection as required by code, see front entry closet 2x6 wall-ADDRESS WITH ENGINEER -seal all top plate penetrations, see above front entry, master bath -min 24” lap between top plate breaks, see covered deck, bed #1, basement-NOT DONE -provide studs and plate at stair wall great room, right side of stairs -Have engineer address the gable truss SE garage wall, bottom cord of truss has been cut out for covered porch beam placement-NO LETTER ON FILE -address top plate lap corner connections 2nd floor bed #2, east corner of exterior wall -provide (4) 2X stud pack all girder truss ends per plans -provide stud shoes at exterior studs bored for DWV master vanity-USE PROPER FASTERS -6’8” head clearance required at basement stairs -CHECK MIDDLE LANDING -provide studs to carry load to foundation wall between plates at basement stair wall-BEHIND FUROUT WALLS -ADDRESS OVER BORED, OVER NOTCHED JOIST BELOW POWDER ROOM
All Rough Inspection - Residential Passed 5/26/2022 5/26/2022 05/26/2022
Misc
Resolved
05/26/2022
-replace the 2x4s at HVAC furred downs at garage ceiling with 2x6s, 2x4s not large enough for R-19 insulation-LOWER ELECTRICAL TO BE AT CEILING HEIGHT -address top plate lap connection at ends steel beam garage walls, no connection with different wall heights-LOWER WALLS NOT CONNECTED TO ANYTHING -support DWV every 48” oc -SEE POWDER ROOM -provide stud shoe at exterior stud bored for DWV 1st floor powder bath -USE PROPER FASTENERS AND REPLACE DAMAGED STUD -address floor joist that has been overnotched for DWV above pantry-HAVE ENGINEER ADDRESS -Seal new through floor penetrations at kitchen -seal all penetrations through air returns-GAS LINES NOT ALLOWED IN RETURN SPACE -provide structural straps at all top plates bored 50% or more all interior load bearing walls and all exterior walls, strap min 1 1/2” wide, 16 gauge, must extend min 6” passed each side of opening with (4) 10D nails each side of strap-SEE KITCHEN -address top plate lap connection as required by code, see front entry closet 2x6 wall-ADDRESS WITH ENGINEER -seal all top plate penetrations, see above front entry, master bath -min 24” lap between top plate breaks, see covered deck, bed #1, basement-NOT DONE -provide studs and plate at stair wall great room, right side of stairs -Have engineer address the gable truss SE garage wall, bottom cord of truss has been cut out for covered porch beam placement-NO LETTER ON FILE -address top plate lap corner connections 2nd floor bed #2, east corner of exterior wall -provide (4) 2X stud pack all girder truss ends per plans -provide stud shoes at exterior studs bored for DWV master vanity-USE PROPER FASTENERS -6’8” head clearance required at basement stairs -CHECK MIDDLE LANDING -provide studs to carry load to foundation wall between plates at basement stair wall-BEHIND FUROUT WALLS -ADDRESS OVER BORED, OVER NOTCHED JOIST BELOW POWDER ROOM
Driveway Inspection Passed 7/14/2022 7/14/2022 07/19/2022
Misc
Informational
07/14/2022
On 7.14.2022 I conducted a driveway inspection and pass the sub-grade to pour concrete 7.19.2022 Driveway appears to be in compliance
Sidewalk Inspection Passed 7/14/2022 7/14/2022 07/19/2022
Misc
Informational
07/14/2022
On 7.14.2022 I conducted a sidewalk inspection and pass the subgrade to pour concrete. 7.19.2022 Sidewalk appears to be in compliance.
Erosion Control Inspection Residential Passed 9/8/2022 9/8/2022 09/08/2022
Misc
Resolved
09/08/2022
-Maintain gravel filter on drive, address before rescheduling inspection
Plot Plan Inspection Passed 9/8/2022 9/8/2022 09/08/2022
Occupancy Inspection - Codes Residential Failed 9/8/2022 9/8/2022 09/08/2022
Misc
Corrective Action Required
09/08/2022
-resolve outstanding inspection fee -install exterior sconce light at garage -install hold or box with cover at kitchen, (exposed romex) -provide security screws at rear deck door -repair rock garage wall -outlet cover plates, see garage and 2nd floor bath -label dedicated outlets at garage and unfinished space as not GFCI protected -have engineer address stud pack bored for added gas line for gas stove at kitchen wall, also gas line appears to pass through HVAC return air which is not allowed by code -provide downspout and splash block rear NW corner, nail corner siding and trim open siding -(2) 1/2” through bolts each post/beam connection at deck -seal all penetrations at siding
Occupancy Inspection - Codes Residential Failed 9/22/2022 9/22/2022 09/22/2022
Misc
Corrective Action Required
09/08/2022
-NO ACCESS FOR INTERIOR INSPECTION, HOUSE LOCKED, NO KEY IN LOCKBOX -install hood or box with cover at kitchen, (exposed romex) -provide security screws at rear deck door -repair rock garage wall -outlet cover plates, see garage and 2nd floor bath -label dedicated outlets at garage and unfinished space as not GFCI protected
Occupancy Inspection - Codes Residential Full C of O 9/26/2022 9/26/2022 09/26/2022
Misc
Resolved
09/26/2022
Documents & Images
Date Uploaded File Type Document Name
08/26/2021 MN #130 - PERMIT APP
08/27/2021 Approved Plans APPROVED PLANS
08/27/2021 Approved Plans APPROVED TRUSS LAYOUT
08/27/2021 Approved Plans APPROVED TRUSS PACKAGE
08/27/2021 Plot Plan APPROVED PLOT PLAN
08/27/2021 Permit Codes Residential Plan Review
09/22/2021 Permit DS Building Permit
09/22/2021 Receipt Receipt for transaction:2021-007517
10/14/2021 130 Manor at Stoney Creek FTNG
10/14/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/24/2022 MN130 truss letter
05/24/2022 130 manor at stoney creek letter (002)
05/26/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
09/14/2022 Receipt Receipt for transaction:2022-007520
09/22/2022 Letter INSPECTION SUMMARY
09/26/2022 Letter Field Certificate of Occupancy
09/26/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home