Permit Application Status

PRRES20214362


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20214362
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. COVERED PATIO.
08/23/2021
08/30/2021
02/22/2022
09/15/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
AJ@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $450.00 $450.00 Paid 08/30/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/30/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/30/2021
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/30/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/30/2021
9110078-Valuation Fee New Single Family $1,023.65 $1,023.65 Paid 08/30/2021
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 08/30/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/11/2021 10/11/2021 10/11/2021
Misc
Informational
10/11/2021
APPROVED PER BRADLEY HUXOL 9/29/21
Underslab Plumbing Inspection - Residential Passed 10/27/2021 10/27/2021 10/27/2021
Erosion Control Inspection Residential Failed 10/27/2021 10/27/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/27/2021
STREET CLEAN UP REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
10/27/2021
Sewer Service Inspection - R Passed 3/28/2022 (8:15) 3/28/2022 03/28/2022
Water Service Inspection - R Passed 3/28/2022 3/28/2022 03/28/2022
Water Service Inspection - R Passed 4/5/2022 (9:15) 4/5/2022 04/05/2022
Electrical Service Inspection Passed 4/22/2022 4/22/2022 04/22/2022
Gas Service Inspection - Residential Passed 4/22/2022 4/22/2022 04/22/2022
All Rough Inspection - Residential Failed 4/22/2022 4/22/2022 04/22/2022
Misc
Corrective Action Required
04/22/2022
-nail off portal straps at garage exterior -nail off all exterior sheathing per plans -replace 2x4s with 2x6s at insulation furred downs in garage ceiling, 2x4 not big enough for R19 insulation -pan off air returns and fur out on garage wall to allow for insulation -seal all top plate penetrations- see garage, 1st floor 1/2 bath, 2nd floor stair wall -seal all penetrations at fireblock along garage wall -address top plate lap connection required by code at NE garage corner -seal all penetrations through air returns -strap all vertical DWV 2” or less at mid point throughout -provide stud shoes for exterior studs bored for DWV at kitchen exterior wall -address the header cut for covered patio beam at great room windows, no king stud -address top plate lap connection required by code at South corner great room -seal gap fireblock lid at fireplace -fireblock plumbing chase great room -Fireblock deadspace at master shower -fireblock at top plate between furring strips at master water closet and north bedroom 2nd floor -provide full bearing for B4 dbl girder truss end at 2nd floor master bed -solid block at all sheathing breaks 2nd floor -provide protection plate sump pump discharge penetration at stair wall -solid block between joists at cantilevers
All Rough Inspection - Residential Passed 5/4/2022 5/4/2022 05/04/2022
Misc
Resolved
05/04/2022
Erosion Control Inspection Residential Partial 5/4/2022 5/4/2022 05/04/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/04/2022
STREET CLEAN UP REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Driveway Inspection Passed 6/13/2022 6/13/2022 06/13/2022
Misc
Informational
06/13/2022
Driveway approach is formed and rock is compacted. MH and water valve lid are not buried and able to be seen.
Piers/Caissons Inspection - Residential Passed 08/31/2022
Misc
Informational
08/31/2022
INSPECTION DONE BY THIRD PARTY.
Erosion Control Inspection Residential Passed 08/31/2022
Driveway Inspection Passed 8/31/2022 08/31/2022
Misc
Informational
06/13/2022
Driveway approach is formed and rock is compacted. MH and water valve lid are not buried and able to be seen.
Misc
Informational
08/31/2022
Driveway meets LS spec. 8/31/22
Occupancy Inspection - Codes Residential Failed 8/31/2022 8/31/2022 08/31/2022
Misc
Corrective Action Required
08/31/2022
-Driveway inspection pending - As graded plot plan required - Provide ladder for Egress window - Adress stairs to basement, both runs are out of compliance.
Plot Plan Inspection Passed 9/1/2022 09/01/2022
Occupancy Inspection - Codes Residential Full C of O 9/15/2022 9/15/2022 09/15/2022
Misc
Resolved
09/15/2022
Documents & Images
Date Uploaded File Type Document Name
08/23/2021 MN #126 - PERMIT APP
08/26/2021 Approved Plans APPROVED TRUSS LAYOUT
08/26/2021 Approved Plans APPROVED TRUSS PACKAGE
08/26/2021 Permit Codes Residential Plan Review
08/30/2021 Plot Plan APPROVED PLOT PLAN
08/30/2021 Approved Plans APPROVED DRAWINGS
08/30/2021 Permit Codes Residential Plan Review
08/30/2021 Permit DS Building Permit
08/30/2021 Receipt Receipt for transaction:2021-006960
10/08/2021 Footing inspection MN126
10/11/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
08/31/2022 Letter INSPECTION SUMMARY
08/31/2022 Letter INSPECTION SUMMARY
08/31/2022 Letter INSPECTION SUMMARY
08/31/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
09/01/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter Field Certificate of Occupancy
09/15/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home