Permit Application Status

PRRES20213806


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213806
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED AND UNCOVERED DECK - ROOF TRUSSES
07/22/2021
09/01/2021
11/01/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $360.00 $360.00 Paid 09/01/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/01/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 09/01/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 09/01/2021
9110078-Valuation Fee New Single Family $955.45 $955.45 Paid 09/01/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/01/2021
8331504-EFHB Middle Big Creek, Full $401.76 $401.76 Paid 10/22/2021
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/20/2023
9110078-Additional Permit Fee $171.32 $171.32 Paid 09/20/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/21/2021 10/21/2021 10/21/2021
Misc
Informational
10/21/2021
APPROVED PER DAVID P AINSWORTH 10/18/21
Underslab Plumbing Inspection - Residential Passed 11/17/2021 11/17/2021 11/17/2021
Sewer Service Inspection - R Passed 11/30/2021 (8:45) 11/30/2021 11/30/2021
Water Service Inspection - R Passed 12/2/2021 (2:00) 12/2/2021 12/02/2021
Erosion Control Inspection Residential Failed 12/2/2021 12/2/2021 12/02/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/02/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 10/17/2022 10/17/2022 10/17/2022
Misc
Corrective Action Required
10/17/2022
10/17/22 - GARAGE PFH PORTAL INSPECTION - NAIL SHEATHING EDGES TO BLOCKING -NAIL SHEATHING EDGES TO SILL PLATE AT PORTAL LEGS
All Rough Inspection - Residential Failed 10/21/2022 10/21/2022 10/21/2022
Misc
Informational
10/21/2022
10/17/22 - GARAGE PFH PORTAL INSPECTION - NAIL SHEATHING EDGES TO BLOCKING -NAIL SHEATHING EDGES TO SILL PLATE AT PORTAL LEGS 10/21/22 GARAGE PFH PORTAL INSPECTION APPROVED
Electrical Service Inspection Failed 11/1/2022 11/1/2022 11/01/2022
Misc
Corrective Action Required
11/01/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE, TRADES ON SITE WORKING AT TIME OF INSPECTION
Gas Service Inspection - Residential Failed 11/1/2022 11/1/2022 11/01/2022
Misc
Corrective Action Required
11/01/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE, TRADES ON SITE WORKING AT TIME OF INSPECTION
All Rough Inspection - Residential Not Ready 11/1/2022 11/1/2022 11/01/2022
Misc
Informational
10/21/2022
10/21/22 GARAGE PFH PORTAL INSPECTION APPROVED
Misc
Corrective Action Required
11/01/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE, TRADES ON SITE WORKING AT TIME OF INSPECTION
Electrical Service Inspection Failed 11/4/2022 11/4/2022 11/04/2022
Misc
Corrective Action Required
11/01/2022
-provide clamp for GEC at UFER rated for dissimilar metal separation of rebar, (acorn style clamp is for copper conductor to copper ground rod)
Gas Service Inspection - Residential Failed 11/4/2022 11/4/2022 11/04/2022
Misc
Corrective Action Required
11/01/2022
-check gauge used for gas pressure test, no movement of needle at pressure test with air loss
All Rough Inspection - Residential Failed 11/4/2022 11/4/2022 11/04/2022
Misc
Resolved
11/04/2022
10/21/22 GARAGE PFH PORTAL INSPECTION APPROVED
Misc
Corrective Action Required
11/01/2022
-protect NM within 6’ of attic entry -secure bath exhaust fan master bath -solid shim trimmer studs cut short of headers throughout -fireblock at top plate between furring strips at stairwall -no top plate corner lap connection at front entry exterior wall -unable to see truss hanger and hold downs at rear deck with lid installed -provide engineer letter from truss manufacturer on solutions for damaged trusses and gusset plates from submitted letter from everstead, also have truss engineer address trusses at great room that have had chords and plates sheared down at wall line -provide nail protection plates at NM that is within 1 1/4” or less from end of stud-see foyer, great room -min 6’8” head clearance required at basement stairs -install patio door at basement -provide protection grommet at conduit sleeve for sump pump basement to protect NM -toenail all floor joists per code -cap and label future vent at basement -solid blocking between joists every 48” at kitchen island, extend blocking one joist bay past each side of island per plans -land all grounds to buss bar at service panel -provide clamp for GEC at UFER rated for dissimilar metal separation of rebar, (acorn style clamp is for copper conductor to copper ground rod) -check gauge used for gas pressure test, no movement of needle at pressure test with air loss
Gas Service Inspection - Residential Passed 11/11/2022 11/11/2022 11/11/2022
Misc
Resolved
11/11/2022
-check gauge used for gas pressure test, no movement of needle at pressure test with air loss
Electrical Service Inspection Passed 11/11/2022 11/11/2022 11/11/2022
Misc
Resolved
11/11/2022
-provide clamp for GEC at UFER rated for dissimilar metal separation of rebar, (acorn style clamp is for copper conductor to copper ground rod)
All Rough Inspection - Residential Passed 11/11/2022 11/11/2022 11/11/2022
Misc
Resolved
11/11/2022
Driveway Inspection Partial 12/1/2022 12/01/2022
Misc
Informational
12/01/2022
12-1-22 RH. Driveway is formed up and aggregate is placed and compacted. Contractor will need to blanket concrete after pour. Approved to pour.
Sidewalk Inspection Partial 12/1/2022 12/01/2022
Misc
Informational
12/01/2022
12-1-22 RH. Sidewalk is formed up and aggregate is placed and compacted. Blankets will need to be used on concrete after pour. Approved to pour.
Driveway Inspection Passed 12/8/2022 12/8/2022 12/08/2022
Misc
Informational
12/01/2022
12-1-22 RH. Driveway is formed up and aggregate is placed and compacted. Contractor will need to blanket concrete after pour. Approved to pour. 12-8-22 RH. Driveway passes ADA and LS specification.
Sidewalk Inspection Passed 12/8/2022 12/8/2022 12/08/2022
Misc
Informational
12/01/2022
12-1-22 RH. Sidewalk is formed up and aggregate is placed and compacted. Blankets will need to be used on concrete after pour. Approved to pour. 12-9-22 RH. Sidewalk meets LS and ADA specification.
Miscellaneous Inspection Passed 5/5/2023 05/05/2023
Misc
Informational
05/05/2023
Project is paused at foundation until a buyer writes a contract for it or another home in the neighborhood sells then we will proceed with OS 26. 05/05/2023 Kyle Beard
Erosion Control Inspection Residential Passed 9/22/2023 09/22/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Passed 9/27/2023 9/27/2023 09/27/2023
Piers/Caissons Inspection - Residential Failed 10/5/2023 (8:30) 10/5/2023 10/05/2023
Miscellaneous Correction
Corrective Action Required
10/05/2023
Stairs and corners of deck post piers passed. The original post deck pier has never passed an inspection and could not be verified for depth or width. Original post carries the deck and roof load. This is a partial pass only.
Piers/Caissons Inspection - Residential Passed 10/6/2023 (11:30) 10/6/2023 10/06/2023
Miscellaneous Correction
Resolved
10/06/2023
Stairs and corners of deck post piers passed. The original post deck pier has never passed an inspection and could not be verified for depth or width. Original post carries the deck and roof load. This is a partial pass only.
Miscellaneous Correction
Corrective Action Required
10/06/2023
Contractor dug next to existing pier for a depth of 36 inches to verify concrete depth. Radius could be verified from removing soil
Plot Plan Inspection Passed 10/27/2023 10/27/2023
Occupancy Inspection - Codes Residential Failed 10/27/2023 10/27/2023 10/27/2023
Misc
Corrective Action Required
10/27/2023
-Missing railing and spindles at garage stairs -Remove plastic cover forms smokes in basement
Occupancy Inspection - Codes Residential Not Ready 10/30/2023 10/30/2023 10/30/2023
Misc
Corrective Action Required
10/27/2023
-Missing railing and spindles at garage stairs -Remove plastic cover forms smokes in basement -Sec. 7-1409.1. - Front and street side exterior lighting. All front and street side door entrances shall be protected with a minimum of one light outlet having a minimum of sixty (60) watts of lighting (or energy efficient equivalent). Those fixtures placed below eight (8) feet shall be fixtures manufactured such that the light source is not "readily accessible" as defined in the adopted National Electrical Code (NEC). (Ord. No. 8584, § 1, 3-19-2019)
Misc
Corrective Action Required
10/30/2023
Sec. 7-1409.1. - Front and street side exterior lighting. All front and street side door entrances shall be protected with a minimum of one light outlet having a minimum of sixty (60) watts of lighting (or energy efficient equivalent). Those fixtures placed below eight (8) feet shall be fixtures manufactured such that the light source is not "readily accessible" as defined in the adopted National Electrical Code (NEC). (Ord. No. 8584, § 1, 3-19-2019)
Occupancy Inspection - Codes Residential Full C of O 11/1/2023 11/1/2023 11/01/2023
Misc
Resolved
11/01/2023
-Missing railing and spindles at garage stairs -Remove plastic cover forms smokes in basement
Misc
Resolved
11/01/2023
Sec. 7-1409.1. - Front and street side exterior lighting. All front and street side door entrances shall be protected with a minimum of one light outlet having a minimum of sixty (60) watts of lighting (or energy efficient equivalent). Those fixtures placed below eight (8) feet shall be fixtures manufactured such that the light source is not "readily accessible" as defined in the adopted National Electrical Code (NEC). (Ord. No. 8584, § 1, 3-19-2019)
Documents & Images
Date Uploaded File Type Document Name
07/22/2021 OS #26 - PERMIT APP
07/23/2021 Approved Plans APPROVED PLANS
07/23/2021 Plot Plan APPROVED PLOT PLAN
07/26/2021 Permit Codes Residential Plan Review
08/31/2021 Approved Plans APPROVED TRUSS LAYOUT
08/31/2021 Approved Plans APPROVED TRUSS PACKAGE
09/01/2021 Permit DS Building Permit
09/01/2021 Receipt Receipt for transaction:2021-007041
10/20/2021 3809 SW Maryville Pl LSMO Osage Lot 26 Clayton Prop Permit 2021-3806 3rd Party Footing Inspection 10-18-21
10/21/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
11/17/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
12/02/2021 Letter INSPECTION SUMMARY
10/17/2022 Letter INSPECTION SUMMARY
10/21/2022 Letter INSPECTION SUMMARY
11/01/2022 OS 26 Truss Repairs
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/04/2022 26 osage truss inspection letter- signed
11/04/2022 Letter INSPECTION SUMMARY
11/04/2022 Letter INSPECTION SUMMARY
11/04/2022 Letter INSPECTION SUMMARY
11/07/2022 I55008982_220006
11/10/2022 OS26 pt_2
11/10/2022 OS26 pt_1
11/11/2022 Letter INSPECTION SUMMARY
11/11/2022 Letter INSPECTION SUMMARY
11/11/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/08/2022 Letter INSPECTION SUMMARY
12/08/2022 Letter INSPECTION SUMMARY
04/27/2023 Letter Codes 140 Day Letter
05/03/2023 OS 26 Permit Extension Form
09/18/2023 OS #26 - BASEMENT FINISH - 09_14_23
09/18/2023 OS 26 - Basement finish - Scope_of_Work
09/18/2023 Approved Plans Basement finish drawing
09/20/2023 Receipt Receipt for transaction:2023-007208
09/22/2023 Letter INSPECTION SUMMARY
09/22/2023 Letter Codes 140 Day Letter
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter Codes 140 Day Letter
10/05/2023 Letter INSPECTION SUMMARY
10/06/2023 Letter INSPECTION SUMMARY
10/27/2023 Letter INSPECTION SUMMARY
10/27/2023 Letter INSPECTION SUMMARY
10/27/2023 Letter Codes Residential Plan Review
10/27/2023 Letter INSPECTION SUMMARY
11/01/2023 Letter Field Certificate of Occupancy
11/01/2023 Letter Codes Final Certificate of Occupancy
11/01/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home