PRRES20213778
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 10/05/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 10/14/2021 12:00 AM by username 'Patrick Schonfeldt'.
07/21/2021
08/05/2021
01/18/2022
09/02/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
AJ@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/05/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/05/2021
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 08/05/2021
8331507-Sewer Connection Fee $450.00 $450.00 Paid 08/05/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/05/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/05/2021
9110078-Valuation Fee New Single Family $1,243.99 $1,243.99 Paid 08/05/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/31/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 10/5/2021 10/5/2021 10/05/2021
Misc
Corrective Action Required
10/05/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION POST ADDRESS
Footing Inspection - Residential Failed - Stop Work 10/5/2021 10/5/2021 10/05/2021
Misc
Corrective Action Required
10/05/2021
FOOTING POURED WITHOUT INSPECTION - ENGINEER REPORTS REQUIRED TO BE UPLOADED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Passed 10/14/2021 10/14/2021 10/14/2021
Misc
Informational
10/14/2021
APPROVED PER BRADLEY HUXOL 8/30/21
Underslab Plumbing Inspection - Residential Passed 10/18/2021 10/18/2021 10/18/2021
Misc
Resolved
10/18/2021
Sewer Service Inspection - R Passed 3/21/2022 (8:15) 3/21/2022 03/21/2022
Water Service Inspection - R Partial 3/21/2022 3/21/2022 03/21/2022
Water Service Inspection - R Passed 3/25/2022 (1:15) 3/25/2022 03/25/2022
Electrical Service Inspection Passed 4/12/2022 4/12/2022 04/12/2022
Gas Service Inspection - Residential Failed 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/12/2022
-provide gauge for gas pressure test
All Rough Inspection - Residential Failed 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/12/2022
-fireblock HVAC chase garage -fur down garage ceiling to allow for insulation -seal all top plate penetrations at garage, great room -protection plates all NM 1 1/4ā€ or less from end of stud - see garage -fireblock vertical to horizontal at box out chases great room -secure Ward flex gas line great room fireplace -seal through floor penetration for gas line fireplace -attic access dbl car bay garage per plans -CS-PF portal bracing per plans at finding room, nail exterior sheathing per plans/IRC R602.10.6.4 -nail all joist hangers 1st floor -provide stud shoes at DWV master bath exterior wall -LIB bracing all locations 2nd floor per plans -exterior bracing design osb 2x6 exterior wall at stair wall per plans -provide 3.5ā€ SCH 40 steel column at pier location ā€œEā€ per plans -have engineer address the W8x28 steel beam not seated in beam pocket partial support by 2x4 bolted to foundation wall -Provide gauge for gas pressure test
Gas Service Inspection - Residential Failed 4/19/2022 4/19/2022 04/19/2022
Misc
Corrective Action Required
04/12/2022
-Gas pressure 0 psi must maintain 10 psi for test
All Rough Inspection - Residential Failed 4/19/2022 4/19/2022 04/19/2022
Misc
Corrective Action Required
04/12/2022
-CS-PF portal bracing per plans at dining room, nail exterior sheathing per plans/IRC R602.10.6.4, (loosen the tyvek, cannot inspect nail pattern covered) -LIB bracing, nail strap min (2) 8D nails each stud and plate -Gas pressure gauge 0 psi, must maintain 10 psi for test OK to insulate
Gas Service Inspection - Residential Not Ready 4/22/2022 4/22/2022 04/22/2022
Misc
Corrective Action Required
04/19/2022
-Gas pressure 3 psi must maintain 10 psi for test
All Rough Inspection - Residential Passed 4/22/2022 4/22/2022 04/22/2022
Misc
Resolved
04/22/2022
Driveway Inspection Partial 5/4/2022 5/4/2022 05/04/2022
Misc
Informational
05/04/2022
On 5.4.2022 I performed a driveway inspection and passed the subgrade to pour concrete. Temp 50 degrees
Gas Service Inspection - Residential Passed 5/4/2022 5/4/2022 05/04/2022
Misc
Resolved
05/04/2022
-Gas pressure 3 psi must maintain 10 psi for test
Driveway Inspection Passed 8/31/2022 8/31/2022 08/31/2022
Misc
Informational
05/04/2022
On 5.4.2022 I performed a driveway inspection and passed the subgrade to pour concrete. Temp 50 degrees
Misc
Informational
08/31/2022
Driveway meets LS spec. 8/31/22 ES
Erosion Control Inspection Residential Passed 8/31/2022 08/31/2022
Piers/Caissons Inspection - Residential Passed 8/31/2022 08/31/2022
Misc
Informational
08/31/2022
Inspection performed by Everstead, third party.
Occupancy Inspection - Codes Residential Failed 8/31/2022 8/31/2022 08/31/2022
Misc
Corrective Action Required
08/31/2022
- pay all fees - As graded plot plan required - No anti-siphon device on main water spigot
Plot Plan Inspection Passed 9/1/2022 09/01/2022
Occupancy Inspection - Codes Residential Full C of O 9/2/2022 9/2/2022 09/02/2022
Misc
Resolved
09/02/2022
- pay all fees - As graded plot plan required - No anti-siphon device on main water spigot
Documents & Images
Date Uploaded File Type Document Name
07/21/2021 MN #127 - PERMIT APP
07/22/2021 Plot Plan Approved Plot Plan
07/22/2021 Approved Plans Approved Truss Layout
07/22/2021 Approved Plans Approved Truss Package
07/22/2021 Permit Codes Residential Plan Review
07/23/2021 Approved Plans Approved Drawings
08/05/2021 Permit Codes Residential Plan Review
08/05/2021 Permit DS Building Permit
08/05/2021 Receipt Receipt for transaction:2021-006248
10/05/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter Stop Work Order
10/13/2021 127 Manor at Stoney Creek FTNG
10/14/2021 Letter INSPECTION SUMMARY
10/18/2021 Letter INSPECTION SUMMARY
03/21/2022 Letter INSPECTION SUMMARY
03/21/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/19/2022 Letter INSPECTION SUMMARY
04/19/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
08/31/2022 Receipt Receipt for transaction:2022-007160
08/31/2022 Plot Plan Approved As Graded Plot Plan
08/31/2022 Letter INSPECTION SUMMARY
08/31/2022 Letter INSPECTION SUMMARY
08/31/2022 Letter INSPECTION SUMMARY
08/31/2022 Letter INSPECTION SUMMARY
09/01/2022 Letter INSPECTION SUMMARY
09/02/2022 Letter Codes Final Certificate of Occupancy
09/02/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home