Permit Application Status

PRRES20213776


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213776
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
07/21/2021
07/22/2021
08/23/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
LOREN@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Right of Way Permit Fee $80.00 $80.00 Paid 07/22/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/22/2021
8331507-Sewer Connection Fee $540.00 $540.00 Paid 07/22/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 07/22/2021
Water Meter Fee $479.24 $479.24 Paid 07/22/2021
Valuation Fee New Single Family $1,310.03 $1,310.03 Paid 07/22/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 07/11/2022
Not Ready Inspection Fee $50.00 $50.00 Paid 07/11/2022
Temporary Occupancy Fee $50.00 $50.00 Paid 07/27/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 8/20/2021 (2:00) 8/20/2021 08/20/2021
Miscellaneous Correction
Corrective Action Required
08/20/2021
-PIER PADS WRONG SIZE AND LOCATION -FORMS DON'T ALLOW FOR CONTINOUS FOOTING -JUMP FOOTINGS ONLY 3" WIDE AT BOTTOM OF FORMS
Footing Inspection - Residential Passed 8/26/2021 8/26/2021 08/26/2021
Miscellaneous Correction
Informational
08/26/2021
APPROVED PER BRADLEY HUXOL 8/23/21
Underslab Plumbing Inspection - Residential Passed 9/28/2021 9/28/2021 09/28/2021
Sewer Service Inspection - R Passed 10/19/2021 (8:45) 10/19/2021 10/19/2021
Water Service Inspection - R Passed 10/21/2021 (11:30) 10/21/2021 10/21/2021
Erosion Control Inspection Residential Failed 10/21/2021 10/21/2021 10/21/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/21/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Piers/Caissons Inspection - Residential Passed 12/6/2021 12/06/2021
Misc
Informational
12/06/2021
(2) PIERS 24"X36"
All Rough Inspection - Residential Not Ready 4/11/2022 4/11/2022 04/11/2022
Misc
Corrective Action Required
04/11/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Electrical Service Inspection Failed 4/11/2022 4/11/2022 04/11/2022
Misc
Corrective Action Required
04/11/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Gas Service Inspection - Residential Failed 4/11/2022 4/11/2022 04/11/2022
Misc
Corrective Action Required
04/11/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
All Rough Inspection - Residential Failed 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/11/2022
- provide nailing to code for PFH portal frame on sheeting - Provide straps for PFH portal frame to top plate - Fire block cantilever and soffit at garage for refrigerator - Complete hvac panning over soffit in garage double bay - Nail all exterior intersecting corners to code - Support DWV in bathroom near garage - Fire block chase soffit at dining room door - Solid block cantilever great room - Fire block triangle chase soffit to garage joist space great room - Nail hangers in entry closet - Snow block bedroom 4 closet corner - Nail all intersecting exterior corners on second floor - Fire block DWV ( radon) in plenum space at basement - Provide flashing for window at stairs landing
Electrical Service Inspection Passed 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/11/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Gas Service Inspection - Residential Passed 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/11/2022
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT TIME OF INSPECTION
Erosion Control Inspection Residential Failed 4/15/2022 04/15/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/15/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
04/15/2022
Maintain gravel filter erosion control at back of lot clean trash from lot
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/15/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 4/15/2022 4/15/2022 04/15/2022
Misc
Corrective Action Required
04/12/2022
- Fire block cantilever and soffit at garage for refrigerator -fire block furr out wall in garage - Support DWV in bathroom near garage - Fire block chase soffit at dining room door - Provide flashing for window at stairs landing
All Rough Inspection - Residential Passed 4/22/2022 4/22/2022 04/22/2022
Misc
Resolved
04/22/2022
- Fire block cantilever and soffit at garage for refrigerator -fire block furr out wall in gar - Support DWV in bathroom near garage - Fire block chase soffit at dining room door - Provide flashing for window at stairs landing
Driveway Inspection Passed 5/9/2022 5/9/2022 05/09/2022
Misc
Informational
05/09/2022
On Monday 5-09-2022 I performed and passed a driveway inspection for placement of concrete.
Occupancy Inspection - Codes Residential Not Ready 6/28/2022 6/28/2022 06/28/2022
Misc
Corrective Action Required
06/28/2022
complete home for inspection handrail not instaill kitchen not completed ect
Occupancy Inspection - Codes Residential Failed 7/26/2022 7/26/2022 07/26/2022
Misc
Corrective Action Required
06/28/2022
-sod -check water meter at time of final grade and sod -handrail at front stoop as required -guard rail at front stoop as required by code -properly illuminated home address -splash blocks and sump pump discharge to extend 36” from foundation -spark rings at kitchen outlets where required by code -security screws at rear door -set screw sheered off at what’re anti syphon device -multiple basement stairs exceeding 7 3/4”
Plot Plan Inspection Passed 7/26/2022 7/26/2022 07/26/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 7/27/2022 7/27/2022 07/27/2022
Misc
Corrective Action Required
07/26/2022
TCO UNTIL 8/27/22 -sod -check water meter at time of final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -spark rings at kitchen outlets where required by code
Occupancy Inspection - Codes Residential Temporary C of O 07/27/2022
Misc
Corrective Action Required
07/27/2022
TCO UNTIL 8/27/22 -sod -check water meter at time of final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -spark rings at kitchen outlets where required by code
Occupancy Inspection - Codes Residential Full C of O 8/23/2022 8/23/2022 08/23/2022
Misc
Resolved
08/23/2022
TCO UNTIL 8/27/22 -sod -check water meter at time of final grade and sod -splash blocks and sump pump discharge to extend 36” from foundation -spark rings at kitchen outlets where required by code
Documents & Images
Date Uploaded File Type Document Name
07/21/2021 H4 #104 - PERMIT APPLICATION
07/21/2021 Approved Plans Approved Drawings
07/21/2021 Approved Plans Approved Truss Layout
07/21/2021 Approved Plans Approved Truss Package
07/22/2021 Plot Plan Approved Plot Plan
07/22/2021 Permit Codes Residential Plan Review
07/22/2021 Permit DS Building Permit
07/22/2021 Receipt Receipt for transaction:2021-005854
08/20/2021 Letter INSPECTION SUMMARY
08/25/2021 104 Hawthorne Ridge FTNG
08/26/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
12/06/2021 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
07/11/2022 Receipt Receipt for transaction:2022-005642
07/21/2022 Letter INSPECTION SUMMARY
07/26/2022 Letter INSPECTION SUMMARY
07/26/2022 Letter INSPECTION SUMMARY
07/27/2022 Receipt Receipt for transaction:2022-006159
07/27/2022 Letter Codes Temporary Certificate of Occupancy
08/23/2022 Letter Codes Final Certificate of Occupancy
08/23/2022 Letter Field Certificate of Occupancy
08/26/2022 Plot Plan Approved As Graded Plot Plan
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home