Permit Application Status

PRRES20213712


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213712
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK ROOF TRUSSES STOP WORK ORDER generated on 10/05/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 10/14/2021 12:00 AM by username 'Patrick Schonfeldt'.
07/19/2021
08/05/2021
09/30/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331504-EFHB Middle Big Creek, Full $401.76 $401.76 Paid 08/05/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 08/05/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/05/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/05/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/05/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/05/2021
9110078-Valuation Fee New Single Family $1,043.12 $1,043.12 Paid 08/05/2021
Outstanding Fees Amount Paid Owing Date Paid
9110078-Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 10/5/2021 10/5/2021 10/05/2021
Misc
Corrective Action Required
10/05/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION POST ADDRESS
Footing Inspection - Residential Failed - Stop Work 10/5/2021 10/5/2021 10/05/2021
Misc
Corrective Action Required
10/05/2021
FOOTING POURED WITHOUT INSPECTION - ENGINEER REPORTS REQUIRED TO BE UPLOADED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Passed 10/14/2021
Misc
Informational
10/14/2021
APPROVED PER BRADLEY HUXOL 8/31/21
Underslab Plumbing Inspection - Residential Passed 10/18/2021 10/18/2021 10/18/2021
Misc
Resolved
10/18/2021
Sewer Service Inspection - R Passed 3/21/2022 (8:15) 3/21/2022 03/21/2022
Water Service Inspection - R Partial 3/21/2022 3/21/2022 03/21/2022
Water Service Inspection - R Passed 3/25/2022 (11:30) 3/25/2022 03/25/2022
Erosion Control Inspection Residential Failed 3/25/2022 3/25/2022 03/25/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/25/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Gas Service Inspection - Residential Passed 4/5/2022 4/5/2022 04/05/2022
Electrical Service Inspection Failed 4/5/2022 4/5/2022 04/05/2022
E3507.5 Main bonding jumper
Corrective Action Required
04/05/2022
SYSTEM GROUNDING. An unspliced main bonding jumper shall be used to connect the equipment grounding conductor(s) and the service-disconnect enclosure to the grounded conductor of the system within the enclosure for each service disconnect. -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
All Rough Inspection - Residential Failed 4/5/2022 4/5/2022 04/05/2022
Miscellaneous Correction
Corrective Action Required
04/05/2022
-Maintain gravel filter to house and erosion control at perimeter -Seal nail penetrations in moisture barrier -Seal upward penetrations at double bay top plate -Address exterior walls not connected at top plate at single car bay -(2) anchor bolts per plate required at single bay step down wall -Top plates lapped less than 24” north garage wall -Nail all multiple ply trusses throughout -J24 truss hanger nails below bottom of GT-face nailed blocks are not approved to support this truss -Address cripple wall at rear garage wall not connected at top plate, and missing top plate in areas, -Truss E01 in master closet not tied to top plate with H2.5, truss is bearing on non full height wall not connected at top plates to exterior load bearing walls -Address truss C05 with less than 1 1/2” bearing and landed on non load bearing wall in laundry -Repair sub floor at master shower -Missing H2.5 at truss J15 above master bath wall -Install bonding screw and jumper at metallic box in master bath -Nail exterior corners and intersecting studs 12” oc -Uncover trusses at covered deck for inspection -Solid block and nail horizontal sheathing seams at front door -(4) studs under GT above bed 3 window -(3) 2x4 stud pack at south side of bed 3 window per plan -(4) 2x4,at GT bearing in bed 3 closet -Protection plate at nm less than 1.25” to face of stud bed 3 NE exterior corner -Address entry wall not connected to exterior walls at top plates -Sister all over notched studs in exterior basement walls notched for bolts -Provide anchor bolt at each end of windows in basement -Provide bonding jumper from ground bar to neutral bar or land CEE on neutral bar -Provide (2) 1/2” through bolts at all post to beam connections at deck -Provide lag bolts or approved fasteners at deck ledger -Install missing hanger nails at deck
Electrical Service Inspection Passed 4/20/2022 4/20/2022 04/20/2022
E3507.5 Main bonding jumper
Resolved
04/20/2022
All Rough Inspection - Residential Passed 4/20/2022 4/20/2022 04/20/2022
Miscellaneous Correction
Resolved
04/20/2022
Occupancy Inspection - Codes Residential Failed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
**BELOW CORRECTIONS CARRIED OVER FROM ALL ROUGH** -Provide (2) 1/2” through bolts at all post to beam connections at deck -Provide lag bolts or approved fasteners at deck ledger -Install missing hanger nails at deck -provide flashing at deck ledger
Erosion Control Inspection Residential Failed 4/20/2022 4/20/2022 04/20/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/20/2022
Misc
Corrective Action Required
04/20/2022
maintain silt fence front of lot
Driveway Inspection Partial 5/4/2022 5/4/2022 05/04/2022
Misc
Informational
05/04/2022
On 5.4.2022 I performed a driveway inspection and passed the subgrade to pour concrete. Temp 50 degrees
Sidewalk Inspection Partial 5/4/2022 5/4/2022 05/04/2022
Misc
Informational
05/04/2022
On 5.4.2022 I performed a sidewalk inspection and passed the subgrade to pour concrete. Temp 50 degrees
Erosion Control Inspection Residential Passed 9/15/2022 9/15/2022 09/15/2022
Misc
Resolved
09/15/2022
maintain silt fence front of lot
Plot Plan Inspection Passed 9/15/2022 9/15/2022 09/15/2022
Occupancy Inspection - Codes Residential Ready for Temp CO 9/15/2022 9/15/2022 09/15/2022
Misc
Corrective Action Required
04/20/2022
-provide flashing at deck ledger -Final driveway and sidewalk inspections required
Sidewalk Inspection Passed 9/16/2022 9/16/2022 09/16/2022
Misc
Informational
05/04/2022
On 5.4.2022 I performed a sidewalk inspection and passed the subgrade to pour concrete. Temp 50 degrees 9-16-22 RH. Sidewalk meets LS and ADA specification.
Driveway Inspection Passed 9/15/2022 9/15/2022 09/16/2022
Misc
Informational
05/04/2022
On 5.4.2022 I performed a driveway inspection and passed the subgrade to pour concrete. Temp 50 degrees 9-16-22 RH. Driveway meets LS and ADA specification.
Occupancy Inspection - Codes Residential Full C of O 9/30/2022 9/30/2022 09/30/2022
Misc
Resolved
09/30/2022
Documents & Images
Date Uploaded File Type Document Name
07/19/2021 MN #129 - PERMIT APP
07/19/2021 Approved Plans APPROVED PLANS
07/19/2021 Approved Plans APPROVED TRUSS DRAWINGS
07/19/2021 Approved Plans APPROVED TRUSS LAYOUT
07/19/2021 Plot Plan APPROVED PLOT PLAN
07/26/2021 Permit Codes Residential Plan Review
08/05/2021 Receipt Receipt for transaction:2021-006249
08/05/2021 Permit Codes Residential Plan Review
08/05/2021 Letter DS Building Permit
10/05/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter Stop Work Order
10/07/2021 MN129 footing inspection
10/13/2021 Footing inspection
10/14/2021 Letter INSPECTION SUMMARY
10/18/2021 Letter INSPECTION SUMMARY
03/21/2022 Letter INSPECTION SUMMARY
03/21/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/05/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
05/04/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter Field Certificate of Occupancy
09/30/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home