Permit Application Status

PRRES20213689


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213689
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK
07/19/2021
08/04/2021
01/15/2022
03/22/2023
Locations
Contacts
TRUMARK HOMES, LLC, Address:424 SE MAXWELL DR, Phone:(816) 564-5613  
TRUMARKHOMES.MARK@GMAIL.COM  
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 346  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,153.38 $1,153.38 Paid 08/04/2021
Right of Way Permit Fee $80.00 $80.00 Paid 08/04/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/04/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 08/04/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 08/04/2021
Water Meter Fee $479.24 $479.24 Paid 08/04/2021
Temporary Occupancy Fee $50.00 $50.00 Paid 02/28/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/10/2021 08/10/2021
Informational
08/10/2021
FOOTING APPROVED BY ENGINEER
Piers/Caissons Inspection - Residential Passed 11/23/2021 (8:00) 11/23/2021 11/23/2021
All Rough Inspection - Residential Failed 12/14/2021 12/14/2021 12/14/2021
Misc
Corrective Action Required
12/14/2021
**RESTORE EROSION CONTROL ALONG THE STREET -Straighten the grounding rod and drive the grounding rod down to earth -Garage PFH wall lvl header not going from corner to corner; wall taller than 12 ft shall be 2x6 -Double up the attic access trimmer joists (opening more than 3 ft from support wall) -Over notched 2x10 rafters at exterior wall bearing -Fb floor penetration at tub trap ; Fb stair wall from soffit -Complete framing at basement bedroom window and complete plumbing soffit in closet and fire block as required **PLAN DOES NOT CALL BUT SHOULD DOUBLE JOISTS UNDER THE KITCHEN ISLAND **OK TO INSULATE
Electrical Service Inspection Passed 12/14/2021 12/14/2021 12/14/2021
Gas Service Inspection - Residential Passed 12/14/2021 12/14/2021 12/14/2021
All Rough Inspection - Residential Failed 1/12/2022 1/12/2022 01/12/2022
Misc
Corrective Action Required
12/14/2021
-Garage PFH wall lvl header not going from corner to corner; wall taller than 12 ft shall be 2x6 **The engineer letter does not address the above code issues -Over notched 2x10 rafters at exterior wall bearing **Code requires max 25% notch at bearing ends of rafters. The engineer letter does not address this deficiency -Complete framing at basement bedroom window and complete plumbing soffit in closet and fire block as required **OK TO INSULATE **A DIFFERENT ENGINEER MAY ADDRESS THE CODE ISSUES ABOVE
All Rough Inspection - Residential Failed 1/19/2022 1/19/2022 01/19/2022
Misc
Corrective Action Required
01/12/2022
-Garage PFH wall lvl header not going from corner to corner; wall taller than 12 ft shall be 2x6 **Not completed per engineer letter **OK TO ROCK HOUSE, BUT NOT THE GARAGE
All Rough Inspection - Residential Passed 1/21/2022 1/21/2022 01/21/2022
Misc
Resolved
01/21/2022
-Garage PFH wall lvl header not going from corner to corner; wall taller than 12 ft shall be 2x6 **Not completed per engineer letter **OK TO ROCK HOUSE, BUT NOT THE GARAGE
Sewer Service Inspection - R Passed 1/26/2022 1/26/2022 01/26/2022
Water Service Inspection - R Partial 1/26/2022 01/26/2022
Water Service Inspection - R Passed 1/26/2022 (1:45) 1/26/2022 01/26/2022
Driveway Inspection Partial 6/2/2022 6/2/2022 06/02/2022
Misc
Informational
06/02/2022
6-2-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 6/7/2022 6/7/2022 06/07/2022
Misc
Informational
06/02/2022
6-2-22 AN forms are in place and aggregate is present and compacted
Misc
Informational
06/07/2022
6-7-22 AN driveway looks good and has expansion joints at curb and right of way. No sidewalk
Occupancy Inspection - Codes Residential Failed 8/26/2022 8/26/2022 08/26/2022
Misc
Corrective Action Required
08/26/2022
-Underslab plumbing not inspected and approved -Final grade, sod, downspout and sump pump extension -Ground meter to rod -Provide lighting outside front door -Provide handrail at foyer stair -Provide secondary lock for the slide door per security code -Remove all items from garage wall -Fb floor penetration below master bathroom tub -Complete electrical to water heater
Occupancy Inspection - Codes Residential Failed 2/16/2023 2/16/2023 02/16/2023
Misc
Corrective Action Required
08/26/2022
-Underslab plumbing not inspected and approved -3 plant bushes required at rear per plot plan missing -Ground meter to rod -Provide secondary lock for the slide door per security code
Occupancy Inspection - Codes Residential Ready for Temp CO 2/28/2023 02/28/2023
Misc
Corrective Action Required
02/16/2023
-3 plant bushes required at rear per plot plan missing -Ground meter to rod -Provide secondary lock for the slide door per security code
Occupancy Inspection - Codes Residential Full C of O 3/22/2023 3/22/2023 03/22/2023
Misc
Resolved
03/22/2023
-3 plant bushes required at rear per plot plan missing -Ground meter to rod -Provide secondary lock for the slide door per security code
Documents & Images
Date Uploaded File Type Document Name
07/19/2021 Application Form Permit Application and License Tax Form
07/19/2021 Approved Plans Approved Drawings
07/19/2021 Permit Codes Residential Plan Review
07/20/2021 Plot Plan Approved Plot Plan
07/20/2021 Permit Codes Residential Plan Review
08/04/2021 Permit DS Building Permit
08/04/2021 Receipt Receipt for transaction:2021-006246
08/09/2021 Garys Fndn 1241 NE Goshen Dr Lee's Summit Mo Footing Inspection Report 8-9-21
08/10/2021 Letter INSPECTION SUMMARY
11/23/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter INSPECTION SUMMARY
01/11/2022 1241 NE Goshen Dr LSMO Lot 69 Monticello Inspection Issues Report 1-10-22 Permit No Corrected
01/12/2022 Letter INSPECTION SUMMARY
01/19/2022 SKM_C36822011907000
01/19/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
06/02/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter INSPECTION SUMMARY
02/16/2023 Letter INSPECTION SUMMARY
02/24/2023 Trumark 69 Monticello Letter
02/28/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/28/2023 Receipt Receipt for transaction:2023-001124
03/22/2023 Letter Field Certificate of Occupancy
03/22/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home