Permit Application Status

PRRES20213401


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213401
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED/UNCOVERED PATIO
07/01/2021
07/06/2021
08/03/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $946.01 $946.01 Paid 07/06/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/06/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/06/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 07/06/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 07/06/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 07/06/2021
8331504-EFHB Middle Big Creek, Full $401.76 $401.76 Paid 10/22/2021
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/18/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/6/2021 10/6/2021 10/06/2021
Misc
Informational
10/06/2021
9/31/2021 David ainsworth
Underslab Plumbing Inspection - Residential Failed 11/3/2021 11/3/2021 11/03/2021
Misc
Corrective Action Required
11/03/2021
Plumbing underwater need pumped out.
Erosion Control Inspection Residential Failed 11/3/2021 11/03/2021
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
11/03/2021
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Sewer Service Inspection - R Passed 11/11/2021 (1:00) 11/11/2021 11/11/2021
Underslab Plumbing Inspection - Residential Passed 11/12/2021 11/12/2021 11/12/2021
Misc
Resolved
11/12/2021
Plumbing underwater need pumped out.
Water Service Inspection - R Passed 11/16/2021 11/16/2021
Gas Service Inspection - Residential Passed 4/20/2022 4/20/2022 04/20/2022
Electrical Service Inspection Failed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
E3607.5 SYSTEM GROUNDING. An unspliced main bonding jumper shall be used to connect the equipment grounding conductor(s) and the service-disconnect enclosure to the grounded conductor of the system within the enclosure for each service disconnect. -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
All Rough Inspection - Residential Failed 4/20/2022 4/20/2022 04/20/2022
Misc
Corrective Action Required
04/20/2022
-provide bocca protection plate at top plate DWV laundry -secure all vertical DWV 2” or less at mid point -install all flashing boots at roof penetrations -min 24” lap at plate breaks dbl top plate , strap plates- see master closet -provide bocca protection plates at bottom plate DWV master vanity/kitchen walls -solid shim at hinges rear exterior door -address top plates not connected at front entry wall, plate height higher at entry wall than opposite plates -seal top plate penetrations - see front bedroom, basement stair wall -Fireblock all tub traps -fireblock unused floor bore at front hall bath -provide (2) 2x4 stud pack for girder truss bearing at rear exterior wall as shown on plans -cap and label future vent basement -address overbored floor joist for DWV, west side basement -address floor joists that have been bored for pex water line less than 2” from end of joist at north basement near sump pump -provide full bearing for W8x10 steel beam in foundation beam pocket -Provide jumper from ground bar to neutral bar or land CEE on neutral bar
Electrical Service Inspection Passed 5/9/2022 5/9/2022 05/09/2022
Misc
Resolved
05/09/2022
All Rough Inspection - Residential Passed 5/9/2022 5/9/2022 05/09/2022
Misc
Resolved
05/09/2022
Erosion Control Inspection Residential Partial 5/9/2022 5/9/2022 05/09/2022
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
05/09/2022
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Driveway Inspection Partial 6/7/2022 6/7/2022 06/07/2022
Misc
Informational
06/07/2022
Driveway approach is formed and ready To pour.
Driveway Inspection Passed 6/9/2022 06/09/2022
Misc
Informational
06/07/2022
Driveway approach is formed and ready To pour.
Misc
Informational
06/09/2022
Approach has been poured and appears to be compliant.
Piers/Caissons Inspection - Residential Passed 6/9/2022 (10:45) 6/9/2022 06/09/2022
Sidewalk Inspection Partial 6/9/2022 6/9/2022 06/09/2022
Misc
Informational
06/09/2022
On 6.9.2022 I performed a sidewalk inspection and passed the subgrade to pour concrete.
Occupancy Inspection - Codes Residential Failed 7/15/2022 7/15/2022 07/15/2022
Miscellaneous Correction
Corrective Action Required
07/15/2022
final grading and sod Splash blocks Sidewalk and driveway inspection pending Missing outlet and switch covers through out Sump discharge minimum of 36” from foundation
Occupancy Inspection - Codes Residential Ready for Temp CO 7/18/2022 7/18/2022 07/18/2022
Miscellaneous Correction
Corrective Action Required
07/15/2022
final grading and sod Splash blocks final Sidewalk inspection pending, contact development services to schedule Sump discharge minimum of 36” from foundation
Occupancy Inspection - Codes Residential Temporary C of O 07/19/2022
Miscellaneous Correction
Corrective Action Required
07/18/2022
final grading and sod Splash blocks final Sidewalk inspection pending, contact development services to schedule Sump discharge minimum of 36” from foundation
Sidewalk Inspection Passed 7/20/2022 7/20/2022 07/20/2022
Misc
Informational
06/09/2022
On 6.9.2022 I performed a sidewalk inspection and passed the subgrade to pour concrete. 7.20.2022 Sidewalk appears to be in compliance
Erosion Control Inspection Residential Passed 8/3/2022 8/3/2022 08/03/2022
Plot Plan Inspection Passed 8/3/2022 8/3/2022 08/03/2022
Occupancy Inspection - Codes Residential Full C of O 8/3/2022 8/3/2022 08/03/2022
Miscellaneous Correction
Resolved
08/03/2022
Documents & Images
Date Uploaded File Type Document Name
07/01/2021 OS #34 - PERMIT APP
07/06/2021 Approved Plans Approved Drawings
07/06/2021 Plot Plan Approved Plot Plan
07/06/2021 Permit Codes Residential Plan Review
07/06/2021 Permit DS Building Permit
07/06/2021 Receipt Receipt for transaction:2021-005361
08/31/2021 Approved Plans APPROVED TRUSS LAYOUT
08/31/2021 Approved Plans APPROVED TRUSS PACKAGE
10/05/2021 M L Crose 2109 SW Rutherford Dr LSMO Osage Lot 34 Clayton P 2021-3401 3rd Party Footing Inspection Report 9-30-21
10/14/2021 Letter INSPECTION SUMMARY
10/22/2021 Receipt Receipt for transaction: 2021-008192
11/03/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
11/12/2021 Letter INSPECTION SUMMARY
11/16/2021 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/20/2022 Letter INSPECTION SUMMARY
04/25/2022 34 Osage Field Issue Letter
05/09/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
05/09/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
06/09/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/18/2022 Receipt Receipt for transaction:2022-005859
07/19/2022 Letter Codes Temporary Certificate of Occupancy
07/21/2022 Letter INSPECTION SUMMARY
08/03/2022 Letter INSPECTION SUMMARY
08/03/2022 Letter INSPECTION SUMMARY
08/03/2022 Letter Field Certificate of Occupancy
08/03/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home