Permit Application Status

PRRES20213385


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213385
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
06/30/2021
07/07/2021
12/28/2021
07/13/2022
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
PERMITTING@JFECONSTRUCTION.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,353.47 $1,353.47 Paid 07/07/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/07/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/07/2021
8331507-Sewer Connection Fee $540.00 $540.00 Paid 07/07/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 07/07/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 07/07/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/12/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/2/2021 09/02/2021
Misc
Informational
09/02/2021
UFER LOCATED SOUTH FOUNDATION WALL ABOUT 8' FROM FRONT FOUNDATION WALL
Underslab Plumbing Inspection - Residential Passed 9/23/2021 9/23/2021 09/23/2021
Underslab Electrical Inspection - Residential Passed 9/28/2021 09/28/2021
Misc
Informational
09/28/2021
underslab conduit at basement wet bar
Sewer Service Inspection - R Passed 9/29/2021 09/29/2021
Water Service Inspection - R Passed 10/1/2021 10/01/2021
All Rough Inspection - Residential Failed 11/9/2021 11/9/2021 11/09/2021
Miscellaneous Correction
Corrective Action Required
11/09/2021
GARAGE PORTAL FRAME ONLY - NAIL STHD14 HOLDDOWNS - GARAGE PORTAL FRAME INSPECTIONS WILL BE DONE WITH ALL ROUGH INSPECTION LEAVE EXPOSED FOR INSPECTION
Electrical Service Inspection Passed 1/27/2022 1/27/2022 01/27/2022
Gas Service Inspection - Residential Passed 1/27/2022 1/27/2022 01/27/2022
All Rough Inspection - Residential Failed 1/27/2022 1/27/2022 01/27/2022
Miscellaneous Correction
Corrective Action Required
11/09/2021
-Insulate cantilever in garage -Have engineer address rafters not connected to ceiling joists at top plates -Provide connection of post to beam at deck and covered deck -Nail rafters to lookouts at great room windows -Have engineer address hip and rafters not connected to top plate at master -Seal through floor penetration at abandoned floor outlet in great room -Support end of ridge above entry -Complete fireblocking in ceiling line at dwv wet bar, closet at bed 3 and at window bed 3 -Sheet rock and fireblocking required under dead space in stairs -(3) studs required at basement corner southeast -Security blocking at basement door -Complete Fireblocking at basement dead space
All Rough Inspection - Residential Not Ready 2/8/2022 2/8/2022 02/08/2022
Miscellaneous Correction
Corrective Action Required
01/27/2022
Have engineer address rafters not connected to ceiling joists at top plates -Provide connection of post to beam at deck and covered deck -Nail rafters to lookouts at great room windows -Have engineer address hip and rafters not connected to top plate at master -Complete fireblocking in ceiling line at closet at bed 3 and at window bed 3 -Sheet rock and fireblocking required under dead space in stairs -(3) studs required at basement corner southeast
All Rough Inspection - Residential Passed 2/14/2022 2/14/2022 02/14/2022
Miscellaneous Correction
Resolved
02/14/2022
Driveway Inspection Partial 5/17/2022 5/17/2022 05/17/2022
Misc
Informational
05/17/2022
Driveway was framed up with aggregate in and compacted. 5/17/22 ES
Driveway Inspection Passed 6/6/2022 6/6/2022 06/06/2022
Misc
Informational
05/17/2022
Driveway was framed up with aggregate in and compacted. 5/17/22 ES Driveway meets LS spec. 6/6/22 ES
Piers/Caissons Inspection - Residential Passed 06/29/2022
Misc
Informational
06/29/2022
piers inspected by third party
Erosion Control Inspection Residential Passed 06/29/2022
Occupancy Inspection - Codes Residential Failed 6/29/2022 6/29/2022 06/29/2022
Misc
Corrective Action Required
06/29/2022
-final grading and sod - Splash blocks -Uncover smoke detectors - Missing hardware on sliding door off kitchen -Provide secondary lock on sliding door off kitchen -Provide spark rings outlets at bar counter - Outlet in basement 1/2 bathroom not working - Manufactured I-joist shall be fire protection In unfinished areas. Exception R302.13.3.1 the aggregate area of the unprotected portion does not exceed 80 square feet per story.
Occupancy Inspection - Codes Residential Temporary C of O 7/7/2022 7/7/2022 07/07/2022
Misc
Corrective Action Required
06/29/2022
-final grading and sod - Splash blocks - pay all fees TCO expiraion 8/6/22
Occupancy Inspection - Codes Residential Full C of O 7/13/2022 7/13/2022 07/13/2022
Misc
Resolved
07/13/2022
Documents & Images
Date Uploaded File Type Document Name
06/30/2021 Application Form Permit Application
06/30/2021 Application Form License Tax Form
07/01/2021 Permit Codes Residential Plan Review
07/01/2021 Plans Approved Plot Plan
07/06/2021 Approved Plans Approved Drawings
07/06/2021 Permit Codes Residential Plan Review
07/07/2021 Permit DS Building Permit
07/07/2021 Receipt Receipt for transaction:2021-005398
09/02/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
09/29/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/19/2021 121 NW Ambersham Dr_DECK PIER INSP_2021-10-15
11/09/2021 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
01/27/2022 Letter INSPECTION SUMMARY
01/31/2022 Letter INSPECTION SUMMARY
02/08/2022 Letter INSPECTION SUMMARY
02/13/2022 121 NW Ambersham Dr__Framing Evaluation Report_2-13-22
02/14/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/31/2022 121 NW Ambersham LS MO Wall Drwgs
06/06/2022 Letter INSPECTION SUMMARY
06/09/2022 Plot Plan Approved Plot Plan with retaining walls
06/09/2022 Approved Plans Approved Retaining wall plan
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter Codes Temporary Certificate of Occupancy
07/12/2022 Receipt Receipt for transaction:2022-005674
07/13/2022 Letter Codes Final Certificate of Occupancy
07/13/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home