Permit Application Status

PRRES20213123


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20213123
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
06/17/2021
07/01/2021
06/27/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/01/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/01/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 07/01/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 07/01/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 07/01/2021
9110078-Valuation Fee New Single Family $872.79 $872.79 Paid 07/01/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/27/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/27/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/21/2021 07/21/2021
Misc
Informational
07/21/2021
3RD PARTY FOOTING BY DEREK PEREZ AT EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED CENTER OF WEST (REAR) GARAGE FOUNDATION WALL
Erosion Control Inspection Residential Failed 8/24/2021 08/24/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/24/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Underslab Plumbing Inspection - Residential Passed 8/24/2021 8/24/2021 08/24/2021
All Rough Inspection - Residential Not Ready 9/2/2021 9/2/2021 09/02/2021
Miscellaneous Correction
Corrective Action Required
09/02/2021
ONLY A FOUNDATION NO FRAMING STARTED
Sewer Service Inspection - R Passed 9/28/2021 (9:00) 9/28/2021 09/28/2021
Water Service Inspection - R Passed 9/30/2021 (1:00) 9/30/2021 09/30/2021
Electrical Service Inspection Passed 2/14/2022 02/14/2022
Gas Service Inspection - Residential Failed 2/14/2022 02/14/2022
Miscellaneous Correction
Corrective Action Required
02/14/2022
CONNECT & SECURE GAS LINE AT FIREPLACE PROVIDE MIN 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Failed 2/14/2022 2/14/2022 02/14/2022
Miscellaneous Correction
Corrective Action Required
02/14/2022
Secure fireplace Provide 1 roof vent covered patio Nail studs at intersecting wall corners at braced wall panels Nail exterior wall sheathing per code Seal DWV AT bottom plate bath 2 Tighten anchor bolts garage & basement Provide anchor bolts within 12" of plate break north basement wall Fire block HVAC soffit north basement wall Provide nut & washer on anchor bolt NW corner basement Provide solid security blocking patio door basement Seal fire blocking top plate south basement wall Provide vertical fire blocking every 10' bed 4 basement Fire block soffit above window bed 4 Provide anchor bolts east of window bed 4 Provide flashing above horizontal window trim window under deck
Gas Service Inspection - Residential Failed 2/25/2022 02/25/2022
Miscellaneous Correction
Corrective Action Required
02/14/2022
CONNECT & SECURE GAS LINE AT FIREPLACE PROVIDE MIN 10 PSI FOR 15 MINUTES
Erosion Control Inspection Residential Failed 2/25/2022 02/25/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/24/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -CLEAN MUD FROM STREET
All Rough Inspection - Residential Failed 2/25/2022 2/25/2022 02/25/2022
Miscellaneous Correction
Corrective Action Required
02/14/2022
Secure fireplace Fire block HVAC soffit north basement CONNECT & SECURE GAS LINE AT FIREPLACE PROVIDE MIN 10 PSI FOR 15 MINUTES
Gas Service Inspection - Residential Failed 3/1/2022 03/01/2022
Miscellaneous Correction
Corrective Action Required
02/25/2022
CONNECT & SECURE GAS LINE AT FIREPLACE PROVIDE MIN 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Not Ready 3/1/2022 3/1/2022 03/01/2022
Miscellaneous Correction
Corrective Action Required
02/25/2022
PROVIDE ADDRESS 3/1/22 Fire block HVAC soffit north basement & bed 4 ( 3/1/22 not done ) CONNECT GAS LINE AT FIREPLACE ( seal upward penetration fireplace floor (3/1/22) PROVIDE MIN 10 PSI FOR 15 MINUTES ( pressure steady at 25 psi)
Driveway Inspection Partial 3/14/2022 3/14/2022 03/14/2022
Misc
Informational
03/14/2022
Driveway was framed up with aggregate in and compacted. 3/14/22 ES
Gas Service Inspection - Residential Passed 03/22/2022
Miscellaneous Correction
Corrective Action Required
03/01/2022
CONNECT & SECURE GAS LINE AT FIREPLACE PROVIDE MIN 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Passed 3/22/2022 3/22/2022 03/22/2022
Miscellaneous Correction
Resolved
03/22/2022
Driveway Inspection Passed 3/25/2022 3/25/2022 03/25/2022
Misc
Informational
03/14/2022
Driveway was framed up with aggregate in and compacted. 3/14/22 ES
Misc
Informational
03/25/2022
Driveway meets LS and Ada spec. 3/25/22 ES
Sidewalk Inspection Failed 4/1/2022 4/1/2022 04/01/2022
Misc
Corrective Action Required
04/01/2022
Forms were placed and aggregate was present, but the forms are out of tolerance and there is too much water for aggregate to be compacted. RP 4-1-22
Sidewalk Inspection Failed 4/8/2022 4/8/2022 04/08/2022
Misc
Corrective Action Required
04/01/2022
Forms were placed and aggregate was present, but the forms are out of tolerance and there is too much water for aggregate to be compacted. RP 4-1-22
Misc
Corrective Action Required
04/08/2022
Sidewalk was never poured. Need to schedule another inspection before pouring in the future. RP 4-8-22
Sidewalk Inspection Partial 4/12/2022 4/12/2022 04/12/2022
Misc
Corrective Action Required
04/08/2022
Forms were placed and aggregate was present, but the forms are out of tolerance and there is too much water for aggregate to be compacted. RP 4-1-22
Misc
Corrective Action Required
04/08/2022
Sidewalk was never poured. Need to schedule another inspection before pouring in the future. RP 4-8-22
Misc
Corrective Action Required
04/12/2022
Forms were placed and aggregate was present and compacted. Forms are still out of tolerance. RP 4-12-22
Misc
Informational
04/12/2022
One of Pat Cochran’s laborers came over and adjusted the frames. They are good to pour now. RP 4-12-22
Sidewalk Inspection Passed 4/22/2022 4/22/2022 04/22/2022
Misc
Corrective Action Required
04/12/2022
Forms were placed and aggregate was present, but the forms are out of tolerance and there is too much water for aggregate to be compacted. RP 4-1-22
Misc
Corrective Action Required
04/12/2022
Sidewalk was never poured. Need to schedule another inspection before pouring in the future. RP 4-8-22
Misc
Corrective Action Required
04/12/2022
Forms were placed and aggregate was present and compacted. Forms are still out of tolerance. RP 4-12-22
Misc
Informational
04/22/2022
Finished sidewalk meets LS and ADA specs. RP 4-22-22
Piers/Caissons Inspection - Residential Passed 06/27/2022
Informational
06/27/2022
INSPECTION BY THIRD PARTY WITH FOOTING.
Erosion Control Inspection Residential Passed 06/27/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/27/2022
Plot Plan Inspection Passed 06/27/2022
Occupancy Inspection - Codes Residential Full C of O 6/27/2022 6/27/2022 06/27/2022
Documents & Images
Date Uploaded File Type Document Name
06/17/2021 W2 #54 - Permit App
06/30/2021 Approved Plans Approved Drawings
06/30/2021 Approved Plans Approved Truss Layout
06/30/2021 Approved Plans Approved Truss Package
06/30/2021 Plot Plan Approved Plot Plan
06/30/2021 Permit Codes Residential Plan Review
07/01/2021 Permit DS Building Permit
07/01/2021 Receipt Receipt for transaction:2021-005265
07/21/2021 54 Woodside Ridge FTNG
07/30/2021 Approved Plans Approved suppl. plans, rear stoop deck
08/24/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
02/14/2022 Letter INSPECTION SUMMARY
02/14/2022 Letter INSPECTION SUMMARY
02/14/2022 Letter INSPECTION SUMMARY
02/25/2022 Letter INSPECTION SUMMARY
02/25/2022 Letter INSPECTION SUMMARY
02/25/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/14/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
06/27/2022 Receipt Receipt for transaction:2022-005174
06/27/2022 Letter Codes Final Certificate of Occupancy
06/27/2022 Letter Field Certificate of Occupancy
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home