Permit Application Status

PRRES20212839


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212839
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND FINISHED BASEMENT - COVERED DECK - ROOF TRUSSES
06/03/2021
06/09/2021
07/01/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/09/2021
8331504-EFHB Middle Big Creek, Full $468.72 $468.72 Paid 06/09/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/09/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/09/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/09/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/09/2021
9110078-Valuation Fee New Single Family $992.15 $992.15 Paid 06/09/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/3/2021 8/3/2021 08/03/2021
Misc
Informational
08/03/2021
APPROVED PER BRADLEY HUXOL 7/29/21
Underslab Plumbing Inspection - Residential Passed 8/19/2021 8/19/2021 08/19/2021
Misc
Corrective Action Required
08/19/2021
Post address
Sewer Service Inspection - R Passed 8/24/2021 08/24/2021
Water Service Inspection - R Partial 8/24/2021 8/24/2021 08/24/2021
Misc
Informational
08/24/2021
PARTIAL ON PEX TO HOUSE ENTRY
Water Service Inspection - R Passed 8/25/2021 (10:00) 8/25/2021 08/25/2021
Misc
Resolved
08/25/2021
Electrical Service Inspection Passed 3/22/2022 3/22/2022 03/22/2022
Gas Service Inspection - Residential Passed 3/22/2022 3/22/2022 03/22/2022
All Rough Inspection - Residential Failed 3/22/2022 3/22/2022 03/22/2022
Misc
Corrective Action Required
03/22/2022
-Address top plate connection as required by code at West and north garage wall -minimum 1” clearance required from combustibles at b vent garage -fireblock b vent chase garage -solid block all sheathing breaks -anchor bolts required within 12” of plate break at garage and basement -provide full bearing support and restraint for covered deck beams at kitchen -seal through floor penetration for gas line at fireplace -minimum 24” offset required between plate breaks - see master bath -seal DWV top plate penetration at master water closet -solid block at sheathing top plate and nail sheathing edges per plans- see kitchen, master bed, garage -TJC37 truss hangers at covered deck J1 hip trusses per plans -provide protection plate at DWV soffit line basement closet -secure 2X to floor joists above to support ceiling load at basement bedroom/closet -seal and Fireblock all penetrations through fireblock material at top plate finished basement -provide nailing of exterior sheathing at garage portal PFH per plans/ IRC R602.10.6.4 -nail all exterior sheathing per plans
All Rough Inspection - Residential Passed 3/25/2022 3/25/2022 03/25/2022
Misc
Resolved
03/25/2022
Driveway Inspection Partial 4/18/2022 04/18/2022
Misc
Informational
04/18/2022
On 4.18.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Plot Plan Inspection Passed 6/28/2022 6/28/2022 06/28/2022
Erosion Control Inspection Residential Passed 06/28/2022
Occupancy Inspection - Codes Residential Failed 6/28/2022 6/28/2022 06/28/2022
Misc
Corrective Action Required
06/28/2022
-FINAL SIDEWALK INSPECTION REQUIRED -6" CLEARANCE REQUIRED BETWEEN SOD AND SIDING AT REAR HOUSE -PROVIDE GRAVEL AT WATER METER BASE
Sidewalk Inspection Passed 6/29/2022 6/29/2022 06/29/2022
Misc
Informational
06/29/2022
On 6/29/2022 the sidewalk inspection appeared to be in compliance.
Driveway Inspection Passed 07/01/2022
Misc
Informational
04/18/2022
On 4.18.2022 I performed a driveway inspection and pass the subgrade to pour concrete Concrete is poured. Driveway passed inspection. 7/1/22 RH
Occupancy Inspection - Codes Residential Full C of O 7/1/2022 7/1/2022 07/01/2022
Misc
Resolved
07/01/2022
Documents & Images
Date Uploaded File Type Document Name
06/03/2021 MN #90 - PERMIT APP
06/03/2021 Approved Plans APPROVED PLANS
06/03/2021 Approved Plans APPROVED PLOT PLAN
06/03/2021 Approved Plans APPROVED TRUSS DRAWINGS
06/03/2021 Approved Plans APPROVED TRUSS LAYOUT
06/04/2021 Permit Codes Residential Plan Review
06/09/2021 Permit DS Building Permit
06/09/2021 Receipt Receipt for transaction:2021-004181
08/02/2021 Lot 90 Manor at Stoney Creek Footing Inspection
08/03/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
08/25/2021 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
04/18/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter INSPECTION SUMMARY
06/29/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter INSPECTION SUMMARY
07/01/2022 Letter Field Certificate of Occupancy
07/01/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home