Summary
PRRES20212838
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED PATIO - SUSPENDED SLAB
06/03/2021
06/29/2021
12/01/2021
06/16/2022
Locations
Contacts
SPELLERBERG ENTERPRISES LLC, Address:613 NE VIEWPARK DR, Phone:(816) 550-5535  
SPELLERBERGENTERPRISES@GMAIL.COM  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
NEW HEIGHTS ELECTRIC LLC, Address:P O BOX 163, Phone:(816) 625-9504  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/29/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/29/2021
8331507-Sewer Connection Fee $690.00 $690.00 Paid 06/29/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 06/29/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 06/29/2021
9110078-Valuation Fee New Single Family $1,507.35 $1,507.35 Paid 06/29/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/6/2021 (11:00) 8/6/2021 08/06/2021
Underslab Plumbing Inspection - Residential Failed 9/14/2021 9/14/2021 09/14/2021
Misc
Corrective Action Required
09/14/2021
-Backfill foundation for access
Underslab Plumbing Inspection - Residential Passed 9/17/2021 9/17/2021 09/17/2021
Misc
Corrective Action Required
09/14/2021
-Backfill foundation for access
Sewer Service Inspection - R Passed 9/20/2021 09/20/2021
Water Service Inspection - R Passed 9/21/2021 (1:00) 9/21/2021 09/21/2021
Suspended Slab Inspection Failed 10/1/2021 (11:00) 10/1/2021 10/01/2021
Misc
Corrective Action Required
10/01/2021
-All dowels to be 12" oc. -Provide min. 1.5" concrete cover at bottom of reinforcement throughout- see dowels resting on metal pan, etc. -Not all dowels are vertically embedded, see NE corner
Piers/Caissons Inspection - Residential Failed 1/14/2022 (8:00) 1/14/2022 01/14/2022
Misc
Corrective Action Required
01/14/2022
-Pump water out of hole right side for inspection
Erosion Control Inspection Residential Failed 01/14/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/14/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -MAINTAIN SILT FENCE
Electrical Service Inspection Failed 2/11/2022 2/11/2022 02/11/2022
Misc
Corrective Action Required
02/11/2022
PROVIDE UFER AS REQUIRED BY CODE E3608.1.2
Gas Service Inspection - Residential Failed 2/11/2022 2/11/2022 02/11/2022
Misc
Corrective Action Required
02/11/2022
GAS LINE BOND REQUIRED
All Rough Inspection - Residential Failed 2/11/2022 2/11/2022 02/11/2022
Misc
Corrective Action Required
02/11/2022
-upload engineer report to portal for garage suspended slab -unable to inspect covered patio with lid installed -Fireblock HVAC/plumbing chase at garage -Fireblock at soffit line above service panel at garage -secure DWV 2” or less at mid point -seal all bottom plate penetrations from NM at garage wall home run -fur down at garage ceiling HVAC to allow for insulation -fur out at garage wall HVAC to allow for insulation -12” oc nailing at all abutting and intersecting wall corners -seal unused top plate bore at pantry -security blocking rear door -fireblock plumbing chase at great room -fireblock HVAC/b vent chase at dining room -Header off floor joist cut for HVAC at dining room chase, floor joist currently supported by non load bearing wall -dbl 2x10 joist at dining room per plan 1st floor -address top plate to top plate connection as required by code, see 2nd floor 2x6 to 2x4 walls -shim trimmer studs to header 2nd floor stair landing windows -dbl top plate requires min 24” offset between plate breaks - see 2nd floor East bedroom, 2nd floor north bedroom -provide stud shoes at 2nd floor bathroom studs bored for DWV on LBW -provide full bearing for lvl ridge at 2nd floor front bedroom -vent all bath exhaust fans to exterior per plans, page D2 -fireblock between top plate and foundation wall throughout at finished basement -Fireblock deadspace at basement bed entry at furred down -address cut floor joist for DWV above furnace basement -fireblock soffit ends of furred downs at finished basement -Provide UFER ground per code -Gas line bond required
All Rough Inspection - Residential Failed 2/24/2022 2/24/2022 02/24/2022
Misc
Corrective Action Required
02/11/2022
-upload engineer report to portal for garage suspended slab -address top plate to top plate connection as required by code, see 2nd floor 2x6 to 2x4 walls -provide stud shoes at 2nd floor bathroom studs bored for DWV on LBW -secure gas flex line above furnace -drop ceiling light box to ceiling line at HVAC furred down garage **OK TO INSULATE**
Erosion Control Inspection Residential Partial 2/24/2022 2/24/2022 02/24/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/24/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -MAINTAIN SILT FENCE
Misc
Corrective Action Required
02/24/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Electrical Service Inspection Failed 2/28/2022 2/28/2022 02/28/2022
Misc
Corrective Action Required
02/11/2022
PROVIDE UFER AS REQUIRED BY CODE E3608.1.2 -THIS CLAMP NEEEDS TO BE ACCESSIBLE. CURRENTLY UNABLE TO EVEN VERIFY THE CONNECTION
Gas Service Inspection - Residential Failed 2/28/2022 2/28/2022 02/28/2022
Misc
Corrective Action Required
02/11/2022
GAS LINE BOND REQUIRED -MUST BE BONDED TO ELECTRICAL SERVICE GROUNDING ELECTRODE SYSTEM
All Rough Inspection - Residential Failed 2/28/2022 2/28/2022 02/28/2022
Misc
Corrective Action Required
02/24/2022
-PLEASE SEE CORRECTIONS ON GAS AND ELECTRICAL SERVICE INSPECTIONS **OK TO INSULATE**
Electrical Service Inspection Passed 3/8/2022 3/8/2022 03/08/2022
Misc
Resolved
03/08/2022
Gas Service Inspection - Residential Passed 3/8/2022 3/8/2022 03/08/2022
Misc
Resolved
03/08/2022
All Rough Inspection - Residential Passed 3/8/2022 3/8/2022 03/08/2022
Misc
Resolved
03/08/2022
Piers/Caissons Inspection - Residential Passed 3/8/2022 (10:15) 3/8/2022 03/08/2022
Misc
Resolved
03/08/2022
Erosion Control Inspection Residential Partial 3/8/2022 3/8/2022 03/08/2022
Misc
Corrective Action Required
02/24/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Driveway Inspection Passed 5/19/2022 5/19/2022 05/19/2022
Misc
Informational
05/19/2022
On Thursday 5-19-2022. I performed and passed a driveway inspection for concrete placement.
Suspended Slab Inspection Passed 05/27/2022
Misc
Informational
05/27/2022
APPROVED PER DAVID P AINSWORTH 10/4/21
Occupancy Inspection - Codes Residential Failed 5/27/2022 5/27/2022 05/27/2022
Misc
Corrective Action Required
05/27/2022
-submit as graded plot plans for review and approval -final sidewalk inspection required, contact development services to schedule -final grade and sod -gutters and downspouts -splash blocks -cover plates at kitchen outlets -GFCI protection required at dishwasher receptacle -install light fixture under stairs at sump pump or cover box -wet bar dishwasher requires GFCI protection
Sidewalk Inspection Passed 6/1/2022 6/1/2022 06/01/2022
Misc
Informational
06/01/2022
On Wednesday 6/1/2022 I conducted a post-pour inspection and the sidewalk is in compliance.
Occupancy Inspection - Codes Residential Temporary C of O 6/1/2022 6/1/2022 06/01/2022
Misc
Corrective Action Required
05/27/2022
-submit as graded plot plans for review and approval -final grade and sod -splash blocks **OK FOR TCO, TCO EXPIRES 6/30/22**
Erosion Control Inspection Residential Partial 06/01/2022
Misc
Corrective Action Required
03/08/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Plot Plan Inspection Passed 6/10/2022 06/10/2022
Erosion Control Inspection Residential Passed 06/16/2022
Misc
Resolved
06/16/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Full C of O 6/16/2022 6/16/2022 06/16/2022
Misc
Resolved
06/16/2022
Documents & Images
Date Uploaded File Type Document Name
06/03/2021 Application Form APPLICATION
06/04/2021 Permit Codes Residential Plan Review
06/07/2021 Approved Plans APPROVED PLANS
06/07/2021 Permit Codes Residential Plan Review
06/29/2021 Permit DS Building Permit
06/29/2021 Receipt Receipt for transaction:2021-005125
08/06/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
09/20/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
01/14/2022 Letter INSPECTION SUMMARY
01/14/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
02/24/2022 Letter INSPECTION SUMMARY
02/24/2022 Letter INSPECTION SUMMARY
02/24/2022 528 SE David Rd LSMO Cobey Creek Lot 7 3rd Party Suspended Slab Inspection 10-4-21
02/28/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
02/28/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
03/08/2022 Letter INSPECTION SUMMARY
05/19/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
06/01/2022 Letter Codes Temporary Certificate of Occupancy
06/01/2022 Letter INSPECTION SUMMARY
06/09/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
06/16/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter Field Certificate of Occupancy
06/16/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home