Permit Application Status

PRRES20212835


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212835
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
06/03/2021
06/09/2021
07/06/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
LOREN@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,302.74 $1,302.74 Paid 06/09/2021
Right of Way Permit Fee $80.00 $80.00 Paid 06/09/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/09/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/09/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 06/09/2021
Water Meter Fee $455.54 $455.54 Paid 06/09/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/30/2021 7/30/2021 07/30/2021
Misc
Informational
07/30/2021
APPROVED PER BRADLEY HUXOL 7/6/21
Underslab Plumbing Inspection - Residential Failed 8/9/2021 8/9/2021 08/09/2021
Misc
Corrective Action Required
08/09/2021
PROTECT UNDERSLAB PEX AT CONCRETE SLAB PENETRATION
Underslab Plumbing Inspection - Residential Passed 8/13/2021 8/13/2021 08/13/2021
Misc
Corrective Action Required
08/09/2021
PROTECT UNDERSLAB PEX AT CONCRETE SLAB PENETRATION
Sewer Service Inspection - R Passed 8/27/2021 (11:30) 8/27/2021 08/27/2021
Water Service Inspection - R Passed 8/31/2021 08/31/2021
Erosion Control Inspection Residential Failed 8/31/2021 8/31/2021 08/31/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/31/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 2/1/2022 2/1/2022 02/01/2022
Gas Service Inspection - Residential Passed 2/1/2022 2/1/2022 02/01/2022
All Rough Inspection - Residential Failed 2/1/2022 2/1/2022 02/01/2022
Misc
Corrective Action Required
02/01/2022
-address great room exterior wall not tied together with dining room exterior wall Seal top plate penetration bed room 2 -nail intsecting wall corner 12” O.C (SW master bedroom) -cs-pf per design and plans at all locations -exterior sheathing per plans -connect bath exhaust fan in master toilet -install and complete all exterior doors and windows -provide protection plate for service cable above secondary panel -steel column (E) to be 3.5” diameter per plans -interior wall stud spacing not to be more than 24”(north wall bar wall & north bed 4 wall) -joist hangers required at stair landing where bearing ends -provide fire blocking at furr down end in basement bed room bath -extend soild blocking one joist bay on either side of island above per plans -provide 3 #2 2x12 joists flush per plans basement unfinished area N side
All Rough Inspection - Residential Failed 3/1/2022 3/1/2022 03/01/2022
Misc
Corrective Action Required
02/01/2022
-Seal top plate penetration bed room 2 -cs-pf per design and plans at all locations see exterior -install and complete all exterior doors and windows -joist hangers required at stair landing where bearing ends did two still one needed Okay to insulate DO NOT COVER ANY ITEMS STILL NEEDING INSPECTION
All Rough Inspection - Residential Failed 3/15/2022 3/15/2022 03/15/2022
Misc
Corrective Action Required
03/01/2022
-cs-pf per design and plans at all locations see exterior Okay to insulate
All Rough Inspection - Residential Passed 3/23/2022 3/23/2022 03/23/2022
Misc
Resolved
03/23/2022
-cs-pf per design and plans at all locations see exterior Okay to insulate
Driveway Inspection Passed 4/4/2022 4/4/2022 04/04/2022
Misc
Informational
04/04/2022
On Monday 4-04-2022, I performed and passed the sub-grade and forms for concrete placement for the driveway.
Sidewalk Inspection Passed 4/4/2022 4/4/2022 04/04/2022
Misc
Informational
04/04/2022
On Monday 4-04-2022, I performed and passed the sidewalk forms and sub-grade for concrete placement.
Piers/Caissons Inspection - Residential Passed 6/3/2022 06/03/2022
Misc
Informational
06/03/2022
Third party inspection performed.
Occupancy Inspection - Codes Residential Temporary C of O 6/3/2022 6/3/2022 06/03/2022
Misc
Corrective Action Required
06/03/2022
TCO UNTIL 7/5/22 -Final grade and sod (submit as graded plot plan) -splash block and sump pump discharge to extend 36" from foundation -check water meter at time of final grade and sod
Plot Plan Inspection Passed 6/7/2022 06/07/2022
Occupancy Inspection - Codes Residential Failed 6/16/2022 6/16/2022 06/16/2022
Misc
Corrective Action Required
06/03/2022
TCO UNTIL 7/5/22 -address siding from ground at back of lot -Bring water meter to grade (must maintain 14"-18" from meter lid to ring lid.
Occupancy Inspection - Codes Residential Full C of O 7/6/2022 7/6/2022 07/06/2022
Misc
Resolved
07/06/2022
TCO UNTIL 7/5/22 -address siding from ground at back of lot -Bring water meter to grade (must maintain 14"-18" from meter lid to ring lid.
Erosion Control Inspection Residential Passed 7/6/2022 07/06/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/31/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Documents & Images
Date Uploaded File Type Document Name
06/03/2021 HT #158 - PERMIT APP
06/03/2021 Approved Plans Approved Drawings
06/03/2021 Approved Plans Approved Truss Layout
06/03/2021 Approved Plans Approved Truss Package
06/03/2021 Plot Plan Approved Plot Plan
06/09/2021 Permit Codes Residential Plan Review
06/09/2021 Permit DS Building Permit
06/09/2021 Receipt Receipt for transaction:2021-004203
07/30/2021 Lot 158 Hawthorne Ridge Footing Inspection
07/30/2021 Letter INSPECTION SUMMARY
08/09/2021 Letter INSPECTION SUMMARY
08/13/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
02/01/2022 Letter INSPECTION SUMMARY
02/01/2022 Letter INSPECTION SUMMARY
02/01/2022 Letter INSPECTION SUMMARY
03/01/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
03/23/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
04/04/2022 Letter INSPECTION SUMMARY
06/06/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
06/08/2022 Letter Codes Temporary Certificate of Occupancy
06/08/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/16/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
07/13/2022 Letter Codes Final Certificate of Occupancy
07/13/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home