Permit Application Status

PRRES20212524


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212524
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK - SUSPENDED SLAB
05/18/2021
06/09/2021
11/14/2021
11/22/2022
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
HIGGINBOTHAM.BRIAN@YAHOO.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,005.75 $1,005.75 Paid 06/09/2021
Right of Way Permit Fee $80.00 $80.00 Paid 06/09/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/09/2021
8331504-EFHB Middle Big Creek, Full $468.72 $468.72 Paid 06/09/2021
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/09/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 06/09/2021
Water Meter Fee $455.54 $455.54 Paid 06/09/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 12/30/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 12/30/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 12/30/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/1/2021 (3:00) 7/1/2021 07/01/2021
Underslab Plumbing Inspection - Residential Passed 8/6/2021 8/6/2021 08/06/2021
Sewer Service Inspection - R Passed 8/24/2021 08/24/2021
Water Service Inspection - R Passed 8/30/2021 (10:15) 8/30/2021 08/30/2021
Gas Service Inspection - Residential Failed 11/16/2021 11/16/2021 11/16/2021
Misc
Corrective Action Required
11/16/2021
GAS LINE BOND REQUIRED
All Rough Inspection - Residential Not Ready 12/16/2021 12/16/2021 12/16/2021
Misc
Corrective Action Required
12/16/2021
INSPECTION DENIED EROSION CONTROL REQUIRED ON LOT CLEAN ALL MUD AND GRAVEL FROM STREET FEE ADDED
Erosion Control Inspection Residential Failed 12/16/2021 12/16/2021 12/16/2021
Misc
Corrective Action Required
12/16/2021
INSPECTION DENIED EROSION CONTROL REQUIRED ON LOT CLEAN ALL MUD AND GRAVEL FROM STREET
All Rough Inspection - Residential Not Ready 12/21/2021 12/21/2021 12/21/2021
Misc
Corrective Action Required
12/16/2021
INSPECTION DENIED 12/21 - EROSION CONTROL REQUIRED ON LOT CLEAN ALL MUD AND GRAVEL FROM STREET FEE ADDED
Erosion Control Inspection Residential Failed 12/21/2021 12/21/2021 12/21/2021
Misc
Corrective Action Required
12/16/2021
INSPECTION DENIED 12/21/21 -EROSION CONTROL REQUIRED ON LOT CLEAN ALL MUD AND GRAVEL FROM STREET
All Rough Inspection - Residential Not Ready 12/27/2021 12/27/2021 12/27/2021
Misc
Corrective Action Required
12/21/2021
INSPECTION DENIED CITY STAMPED PLANS REQUIRED ON SITE FOR INSPECTION (3) NOT READY FEES
Electrical Service Inspection Passed 12/28/2021 12/28/2021 12/28/2021
Gas Service Inspection - Residential Passed 12/28/2021 12/28/2021 12/28/2021
Misc
Resolved
12/28/2021
Piers/Caissons Inspection - Residential Failed 12/28/2021 12/28/2021 12/28/2021
Misc
Corrective Action Required
12/28/2021
NO INSPECTION PERFORMED ON COVERED DECK PIERS, SUBMIT ENGINEER LETTER
All Rough Inspection - Residential Failed 12/28/2021 12/28/2021 12/28/2021
Misc
Corrective Action Required
12/27/2021
-Anchor bolts required within 12” of plate breaks at garage and basement -Anchor bolt garage PFH, 5/8” bolt with 2”x2”x 3/16” plate washer -PFH portal design single car garage per plans -Bolt bottom plate between dbl/sgl car garage -Rafter/ceiling joist/top plate connection per code- have engineer address rafters landing on blocks and smart siding above ceiling joist, rafters landing on blocks above top plate, have engineer address hips landing on blocks and not top plate -Fireblock at bottom plate steel beam garage -provide structural straps at all interior load bearing walls and all exterior walls bored 50% or more, strap should be 16 ga, 1 1/2” wide and extend 6” passed both side of opening with (4) 10D nails each side of strap -provide bocca protection plate at DWV garage wall, plate must protect at plate and either 2” below top plate or 2” above bottom plate -provide protection plate at pex bottom plate kitchen fridge -solid block between studs at cripple wall above lvl kitchen/great room per plans -fireblock between studs at great room fireplace lid, open to attic space above -provide joist hanger at dbl joist ceiling box out foyer -fireblock master shower soffit ends -add security blocking at master bed door and breakfast door to deck -CS-PF wall bracing at breakfast windows per plans, see detail A4 -purlins not less than 45 degree angle -Ensure proper slope all DWV vents span across tops of ceiling joists in attic space -complete electrical at suspended slab basement -no inspection performed suspended slab -add joist hangers at sgl to dbl joist connection at fireplace cantilever basement -provide joist hangers at joist to dbl joist connection, both sides stair wall at basement -2x4 laid flat at furred downs, connect to ceiling joists above to support the ceiling load -provide bocca protection plate at top plate wet bar -solid block between joists at cantilevers -Have engineer update plans to reflect change of fireplace locations with cantilever -Unable to inspect nail pattern at exterior sheathing with siding cover -Nail exterior sheathing per plans -No pier inspection performed at covered deck, submit engineer letter
Piers/Caissons Inspection - Residential Passed 1/5/2022 1/5/2022 01/05/2022
Misc
Informational
01/05/2022
APPROVED PER CHAD M STREETER 11/18/21 & 1/3/22
Suspended Slab Inspection Passed 1/5/2022 1/5/2022 01/05/2022
Misc
Informational
01/05/2022
APPROVED PER CHAD M STREETER 11/18/21
All Rough Inspection - Residential Failed 1/24/2022 1/24/2022 01/24/2022
Misc
Corrective Action Required
12/28/2021
-provide structural straps at all interior load bearing walls and all exterior walls bored 50% or more, strap should be 16 ga, 1 1/2” wide and extend 6” passed both side of opening with (4) 10D nails each side of strap -see garage wall, master bath exterior wall -complete electrical at suspended slab storage basement -provide joist hangers at joist to dbl joist beam connection, stair wall at basement, see East wall
All Rough Inspection - Residential Passed 1/26/2022 1/26/2022 01/26/2022
Misc
Resolved
01/26/2022
Driveway Inspection Partial 4/1/2022 4/1/2022 04/01/2022
Misc
Informational
04/01/2022
On Friday 4.1.2022 I performed a driveway inspection and pass the subgrade to pour concrete
Sidewalk Inspection Partial 4/1/2022 4/1/2022 04/01/2022
Misc
Informational
04/01/2022
On Friday 4.1.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete
All Rough Inspection - Residential Passed 5/12/2022 05/12/2022
Misc
Informational
05/12/2022
ALL ROUGH COMPLETED ON 1/26/22, HOUSE NOT READY FOR OCCUPANCY INSPECTION
Occupancy Inspection - Codes Residential Failed 5/16/2022 5/16/2022 05/16/2022
Miscellaneous Correction
Corrective Action Required
05/16/2022
- final grading and sod - Splash blocks - Driveway inspection pending - Sidewalk inspection pending - Outlets at island not GFCI protected - Provide steps for Egress window - Provide spark rings at bar counter outlets - Missing switch plate near bar
Occupancy Inspection - Codes Residential Temporary C of O 5/18/2022 5/18/2022 05/18/2022
Miscellaneous Correction
Corrective Action Required
05/16/2022
TCO UNTIL 6/17/22 -guard rail at front stoop as required - final grading and sod - Splash blocks - Driveway inspection pending - Sidewalk inspection pending
Driveway Inspection Passed 5/17/2022 07/12/2022
Misc
Informational
04/01/2022
On Friday 4.1.2022 I performed a driveway inspection and pass the subgrade to pour concrete 7.12.2022 Driveway appears to in compliance
Sidewalk Inspection Passed 5/17/2022 07/12/2022
Misc
Informational
04/01/2022
On Friday 4.1.2022 I performed a sidewalk inspection and pass the subgrade to pour concrete 7.12.2022 Sidewalk appears to be in compliance
Erosion Control Inspection Residential Passed 11/2/2022 11/2/2022 11/02/2022
Misc
Resolved
11/02/2022
INSPECTION DENIED 12/21/21 -EROSION CONTROL REQUIRED ON LOT CLEAN ALL MUD AND GRAVEL FROM STREET
Plot Plan Inspection Passed 11/2/2022 11/2/2022 11/02/2022
Occupancy Inspection - Codes Residential Full C of O 11/2/2022 11/2/2022 11/02/2022
Miscellaneous Correction
Resolved
11/02/2022
Documents & Images
Date Uploaded File Type Document Name
05/18/2021 Application Form Permit Application
05/18/2021 Application Form License Tax Form
05/18/2021 1816 sw sage canyon KH-6105 (LOT 151) 5-10-2021
05/18/2021 Permit Codes Residential Plan Review
05/24/2021 Plot Plan Approved Plot Plan
06/09/2021 Approved Plans Approved Drawings
06/09/2021 Permit Codes Residential Plan Review
06/09/2021 Permit DS Building Permit
06/09/2021 Receipt Receipt for transaction:2021-004228
07/01/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
11/16/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
12/21/2021 Letter INSPECTION SUMMARY
12/27/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
12/30/2021 1816 SW Sage Canyon Rd_SUS STOOP & DECK PIER INSP_2021-11-18
12/30/2021 Receipt Receipt for transaction:2021-009587
01/04/2022 1816 SW Sage Canyon Rd_DECK PIER INSP_2022-01-03
01/05/2022 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/18/2022 1816 SW Sage Canyon Rd, Inspection comment items
01/19/2022 Approved Plans Approved Change of Fireplace
01/24/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter INSPECTION SUMMARY
01/26/2022 1817 SW SAGE CANYON RD FTG INSP
04/01/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
05/12/2022 Letter INSPECTION SUMMARY
05/16/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter Codes Temporary Certificate of Occupancy
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter INSPECTION SUMMARY
11/02/2022 Letter Codes Final Certificate of Occupancy
11/02/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home