Permit Application Status

PRRES20212482


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212482
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT
05/14/2021
05/14/2021
02/22/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $540.00 $540.00 Paid 05/14/2021
Right of Way Permit Fee $80.00 $80.00 Paid 05/14/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/14/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 05/14/2021
Water Meter Fee $455.54 $455.54 Paid 05/14/2021
Valuation Fee New Single Family $1,185.77 $1,185.77 Paid 05/14/2021
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/3/2021 06/03/2021
Underslab Plumbing Inspection - Residential Passed 7/7/2021 7/7/2021 07/07/2021
Sewer Service Inspection - R Passed 7/9/2021 (8:00) 7/9/2021 07/08/2021
Water Service Inspection - R Passed 7/9/2021 (1:00) 7/9/2021 07/09/2021
Erosion Control Inspection Residential Failed 7/9/2021 7/9/2021 07/09/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/09/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Failed 8/25/2021 8/25/2021 08/25/2021
Miscellaneous Correction
Informational
08/25/2021
*8-25-21 -Portal framing exterior ok to cover -Front porch trusses ok to cover
All Rough Inspection - Residential Failed 10/26/2021 10/26/2021
Miscellaneous Correction
Informational
08/25/2021
*8-25-21 -Portal framing exterior ok to cover -Front porch trusses ok to cover
Misc
Corrective Action Required
10/26/2021
-Fasten top plate to header with 16D sinker nails 3" o.c. at garage PFH -Fireblock all HVAC and plumbing chases and bump outs at garage wall -seal penetrations at fireblock garage wall -Fir down at garage ceiling HVAC to allow for insulation -Attic access garage sgl car bay per plans -support all DWV every 48” oc, traps not considered support -Address over bored floor joist above kitchen for DWV -seal all top and bottom plate penetrations throughout -overbored studs for DWV at 1st floor powder room, bearing wall -Fireblock 1st floor chase at great room -Top plate connection, 1st floor stair wall at great room exterior wall -Fir down for HVAC at great room windows -LIB bracing foyer wall per plans -Nail all LIB bracing straps at studs -Exterior bracing CS-PF at flex room wall per plans -Connect 2x6 to 2x4 top plates at 2nd floor stairs -Top plate connection required of exterior walls NW corner 2nd floor bedroom and SW wall at master bedroom -Fireblock between studs at 2nd floor bath#2 and bed #2 south wall line, will be open to attic space above -Dbl top plate requires 24” min offset between plate breaks - see 2nd floor bed#3 -stud missing 2nd floor laundry -complete duct at 2nd floor master bath exhaust -move low volt wire off b vent at furnace, 1” min clearance -Nail exterior sheathing per plans
Gas Service Inspection - Residential Failed 10/26/2021 10/26/2021 10/26/2021
Misc
Corrective Action Required
10/26/2021
Gas pressure at 0 psi, must maintain 10 psi for test
Electrical Service Inspection Failed 10/26/2021 10/26/2021 10/26/2021
Misc
Corrective Action Required
10/26/2021
-Use clamp as designed for separation at UFER -Identify UFER ground at points of termination
All Rough Inspection - Residential Passed 11/3/2021 11/3/2021 11/03/2021
Miscellaneous Correction
Resolved
11/03/2021
*8-25-21 -Portal framing exterior ok to cover -Front porch trusses ok to cover
Misc
Resolved
11/03/2021
Electrical Service Inspection Passed 11/9/2021 11/9/2021 11/09/2021
Misc
Resolved
11/09/2021
Gas Service Inspection - Residential Passed 11/11/2021 11/11/2021 11/11/2021
Misc
Resolved
11/11/2021
Gas pressure at 0 psi, must maintain 10 psi for test
Driveway Inspection Passed 12/01/2021
Misc
Informational
12/01/2021
On Tuesday, 11-30-2021. The contractor called me directly and requested the drive way inspection. I was passed to pour concrete. Contractor called in the inspection on today, 12-01-2021 and I have sign it off passing!
Sidewalk Inspection Passed 12/1/2021 12/1/2021 12/01/2021
Misc
Informational
12/01/2021
On Tuesday, 11-30-2021. The contractor called me directly and requested the sidewalk inspection but did not call the inspection in to the office. The sidewalk passed inspection and is being signed off passed.
Occupancy Inspection - Codes Residential Failed 1/18/2022 1/18/2022 01/18/2022
Misc
Corrective Action Required
01/18/2022
-Final grade and sod -check water meter and siding from ground at time of final grade and sod -handrail height in garage to comply with code section R311.7.8.1
Plot Plan Inspection Passed 2/22/2022 02/22/2022
Erosion Control Inspection Residential Passed 2/22/2022 02/22/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/22/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Full C of O 2/22/2022 2/22/2022 02/22/2022
Misc
Resolved
02/22/2022
-Final grade and sod -check water meter and siding from ground at time of final grade and sod -handrail height in garage to comply with code section R311.7.8.1
Documents & Images
Date Uploaded File Type Document Name
05/14/2021 108 HAWTHORNE RIDGE TRUSS LAYOUT
05/14/2021 H4 #108 - PERMIT APP
05/14/2021 210411
05/14/2021 H4 #108 - Winfield - Craftsman - F12x12 - Sheets- signed
05/14/2021 LOT 108 FINAL
05/14/2021 Approved Plans APPROVED PLANS
05/14/2021 Approved Plans APPROVED TRUSS DRAWINGS
05/14/2021 Approved Plans APPROVED TRUSS LAYOUT
05/14/2021 Plot Plan APPROVED PLOT PLAN
05/14/2021 Permit Codes Residential Plan Review
05/14/2021 Permit DS Building Permit
05/14/2021 Receipt Receipt for transaction:2021-003032
06/03/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
08/25/2021 Letter INSPECTION SUMMARY
10/26/2021 Letter INSPECTION SUMMARY
10/26/2021 Letter INSPECTION SUMMARY
10/26/2021 Letter INSPECTION SUMMARY
11/03/2021 108 Hawthorne Ridge Holes in Floor Joists Stud Top Plate Letter
11/03/2021 Letter INSPECTION SUMMARY
11/09/2021 Letter INSPECTION SUMMARY
11/11/2021 Letter INSPECTION SUMMARY
12/01/2021 Letter INSPECTION SUMMARY
12/01/2021 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter Codes Final Certificate of Occupancy
02/22/2022 Letter Field Certificate of Occupancy
02/22/2022 Letter INSPECTION SUMMARY
02/22/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home