Summary
PRRES20212323
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT -
05/07/2021
05/24/2021
11/07/2021
09/30/2023
Locations
Contacts
H & R CONSTRUCTION LLC, Address:1200 S POWELL RD STE A, Phone:(816) 229-4853  
Josh Ward, Address:5403 W. 40 Highway , Phone:(816) 229-4853  
JOSH@HOUSEANDRENNER.COM  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $360.00 $360.00 Paid 05/24/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/24/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/24/2021
9110078-Valuation Fee New Single Family $1,089.37 $1,089.37 Paid 05/24/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 05/24/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 05/24/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/23/2023
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/23/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/26/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/4/2021 6/4/2021 06/04/2021
Misc
Informational
06/04/2021
3rd party inspection: approved by David Ainsworth on 6-2-21
Erosion Control Inspection Residential Failed 6/7/2021 6/7/2021 06/07/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/07/2021
**6-7-21 -DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL REQUIRED TO BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -EROSION CONTROL IS REQUIRED TO BE MAINTAINED THROUGHT THE JOB. RESTORE SILT FENCE AT PERIMETER OF LOT AND CLEAN DEBRIS FROM THE STREET
Erosion Control Inspection Residential Not Ready 6/10/2021 6/10/2021 06/10/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/07/2021
**6-7-21 -DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL REQUIRED TO BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -EROSION CONTROL IS REQUIRED TO BE MAINTAINED THROUGHT THE JOB. RESTORE SILT FENCE AT PERIMETER OF LOT AND CLEAN DEBRIS FROM THE STREET
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/10/2021
**6-9-21 -FEE ACCESSED- -RESTORE DAMAGED AND PROVIDE ADEQUATE EROSION CONTROL METHODS AT PERIMETER OF LOT AND AROUND ALL STOCK PILES -CLEAN TRASH FROM LOT -EROSION CONTROL REQUIRES CONSTANT ATTENTION THROUGHOUT THE PROJECT EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 6/22/2021 6/22/2021 06/22/2021
Misc
Corrective Action Required
06/22/2021
-Post address
Water Service Inspection - R Passed 8/20/2021 (1:00) 8/20/2021 08/20/2021
Erosion Control Inspection Residential Failed 8/23/2021 08/23/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/10/2021
**8-23-21 -DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL REQUIRED TO BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -EROSION CONTROL IS REQUIRED TO BE MAINTAINED THROUGHT THE JOB. RESTORE SILT FENCE AT PERIMETER OF LOT AND CLEAN DEBRIS FROM THE STREET -POST ADDRESS
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/23/2021
**6-9-21 -FEE ACCESSED- -RESTORE DAMAGED AND PROVIDE ADEQUATE EROSION CONTROL METHODS AT PERIMETER OF LOT AND AROUND ALL STOCK PILES -CLEAN TRASH FROM LOT -EROSION CONTROL REQUIRES CONSTANT ATTENTION THROUGHOUT THE PROJECT EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 10/7/2021 10/7/2021 10/07/2021
Misc
Corrective Action Required
10/07/2021
-Provide city approved, stamped plans on site for inspection
All Rough Inspection - Residential Failed 10/11/2021 10/11/2021 10/11/2021
Misc
Corrective Action Required
10/07/2021
-Nail all exterior sheathing per code -Complete portal frame nailing pattern, anchor bolts, washer, etc. at PFH -Unable to verify nailing pattern at exterior braced walls bed 3 -Nail all corner and intersecting wall studs per code -Finish lookouts in garage -Provide lateral restraint at ends of LVL beam in garage -Solid block and nail horizontal seams at single car bay sheathing -Address sheathing not nailed to top plate west exterior wall, master bed north, bed 3 East -Seal upward penetration at garage/laundry -Provide proper slope at vent lines in attic -Nail rafter to joist connections per code -Solid block and nail sheathing seams at master bed header -Missing ceiling joist at great room -Joist hanger at lvl/kitchen -Correct mis-installed joist hanger at lvl great room -Strap top plates at exterior corner bed 3 where top plates don’t overlap -Seal upward penetration East wall bed 2 -Block and nail seam above window bed 2 -Complete vent for fireplace -Address bed 2 exterior corners not tied together at top plate -LIB throughout -Double lvl at covered patio -(2) 2x6 at master bed beam under beam -Seal joist space penetrations in return air near bath -Identify white insulated conductors as current carrying conductors at both ends ac circuit -Bond metallic gas line before first connection of csst -Seal gaps in fireblocking behind basement shower -FB vertical 10’ oc max at furout walls -FB beam webs in finished walls -Seal gaps at ceiling fireblocking at basement bath -FB soffit line at steel column by stairs -Block between joist above beam at southeast basement
Gas Service Inspection - Residential Failed 10/11/2021 10/11/2021
Misc
Corrective Action Required
10/11/2021
-Bond metallic gas line before 1st csst connection
Electrical Service Inspection Failed 10/11/2021 10/11/2021
Misc
Corrective Action Required
10/11/2021
-Identify white insulated conductors as current carrying conductors at both ends ac circuit -Bond metallic gas line before first connection of csst
Gas Service Inspection - Residential Passed 10/14/2021 10/14/2021 10/14/2021
Misc
Resolved
10/14/2021
-Bond metallic gas line before 1st csst connection
Electrical Service Inspection Passed 10/14/2021 10/14/2021 10/14/2021
Misc
Resolved
10/14/2021
-Identify white insulated conductors as current carrying conductors at both ends ac circuit -Bond metallic gas line before first connection of csst
All Rough Inspection - Residential Failed 10/14/2021 10/14/2021 10/14/2021
Misc
Corrective Action Required
10/11/2021
-Finish lookouts in garage -Solid block and nail horizontal seams at single car bay sheathing and nail -Address sheathing not nailed to top plate west exterior wall, master bed north, bed 3 East -Provide proper slope at vent lines in attic -Solid block and nail sheathing seams at master bed header 2 -Block and nail seam above window bed 2 -Seal joist space penetrations in return air
All Rough Inspection - Residential Passed 10/18/2021 10/18/2021 10/18/2021
Misc
Resolved
10/18/2021
-Address sheathing not nailed to top plate west exterior wall, master bed north, bed 3 East -Provide proper slope at vent lines in attic -Solid block and nail sheathing seams at master bed header 2
Sewer Service Inspection - R Not Ready 11/5/2021 (8:00) 11/5/2021 11/05/2021
Driveway Inspection Passed 1/18/2022 1/18/2022 01/18/2022
Misc
Informational
01/18/2022
On Tuesday. 1-18-2021. I performed a driveway inspection and passed driveway for concrete placement.
Sidewalk Inspection Passed 1/18/2022 01/18/2022
Occupancy Inspection - Codes Residential Failed 1/23/2023 1/23/2023 01/23/2023
Misc
Corrective Action Required
01/23/2023
-address pending pier inspection -address pending sewer inspection -provide as graded plot plan -pay all fees -provide lawn irrigation permit -set screw sheered off at water anti syphon device -address siding from grade at west side of home -stairs at rear patio greater than 3/8 difference in rise
Plot Plan Inspection Passed 1/24/2023 01/24/2023
Sewer Service Inspection - R Passed 01/25/2023
Occupancy Inspection - Codes Residential Ready for Temp CO 1/26/2023 1/26/2023 01/26/2023
Misc
Corrective Action Required
01/23/2023
-address siding from grade at west side of home
Occupancy Inspection - Codes Residential Ready for Temp CO 8/3/2023 08/03/2023
Misc
Corrective Action Required
01/26/2023
-address siding from grade at west side of home
Occupancy Inspection - Codes Residential Ready for Temp CO 9/5/2023 09/05/2023
Misc
Corrective Action Required
08/03/2023
-address siding from grade at west side of home
Miscellaneous Correction
Corrective Action Required
09/05/2023
-address siding from grade at west side of home -pay all fees associated with permit if any 09/05/23 KBEARD
Occupancy Inspection - Codes Residential Full C of O 09/30/2023
Misc
Resolved
09/30/2023
-address siding from grade at west side of home
Miscellaneous Correction
Resolved
09/30/2023
-address siding from grade at west side of home -pay all fees associated with permit if any 09/05/23 KBEARD
Documents & Images
Date Uploaded File Type Document Name
05/07/2021 28 Cobey Creek Staked
05/07/2021 2021_04_23_Lot 28 Cobey Creek_Permit Set_Sealed_Lees Summit
05/10/2021 2021_04_23_Lot 28 Cobey Creek_Permit Set_Sealed_Lees Summit
05/10/2021 28 Cobey Creek Revised MBOE
05/11/2021 CC28 Permit App 5_11_21
05/11/2021 Permit Codes Residential Plan Review
05/19/2021 2021_04_23_Lot 28 Cobey Creek_Permit Set_Sealed_Lees Summit
05/19/2021 28 Cobey Creek Revised
05/20/2021 Plot Plan APPROVED PLOT PLAN
05/20/2021 Approved Plans APPROVED PLANS
05/20/2021 Permit Codes Residential Plan Review
05/24/2021 Permit DS Building Permit
05/24/2021 Receipt Receipt for transaction:2021-003448
06/03/2021 Garys Fndn 532 SE Carter Rd Greenwood Mo Cobey Creek Lot 28 3rd Party Footing Inspection Report 6-2-21
06/04/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter INSPECTION SUMMARY
06/10/2021 Letter INSPECTION SUMMARY
06/22/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/11/2021 Letter INSPECTION SUMMARY
10/11/2021 Letter INSPECTION SUMMARY
10/11/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/18/2021 Letter INSPECTION SUMMARY
11/05/2021 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
01/23/2023 Letter INSPECTION SUMMARY
01/23/2023 28 Cobey Creek As Graded Plot plan
01/23/2023 Receipt Receipt for transaction:2023-000418
01/23/2023 Plot Plan APPROVED AS GRADED PLOT PLAN
01/24/2023 Letter INSPECTION SUMMARY
01/25/2023 Final_2023_01_24_PostPour DPier_LSMO_Pat Cochran Concrete
01/25/2023 Final_2023_01_24_PostPour DPier_LSMO_Pat Cochran Concrete
01/25/2023 Letter INSPECTION SUMMARY
01/25/2023 532 Carter Sewer
01/26/2023 Certificate/License Codes Temporary Certificate of Occupancy
01/26/2023 Receipt Receipt for transaction:2023-000529
09/30/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home