Permit Application Status

PRRES20211893


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211893
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINSIHED BASEMENT - RETAINING WALL PERMIT
04/20/2021
04/23/2021
02/01/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/26/2021 04/22/2021
Brandon Kalwei
Residential Plan Review Approved 04/26/2021 04/22/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,267.87 $1,267.87 Paid 04/23/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 04/23/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/23/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/23/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/23/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/23/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 5/17/2021 05/17/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/17/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - SOIL STOCKPILES SHOULD NOT BE LOCATED NEAR THE STREET, STORM INLETS, LOT ACCESS, OR ADJACENT PROPERTY LINES. ALL STOCKPILES MUST EITHER BE STABILIZED, COVERED, OR HAVE ESC AND BMPs INSTALLED AROUND BASE OF THE PILE -
Footing Inspection - Residential Passed 5/17/2021 05/17/2021
Misc
Informational
05/17/2021
3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED IN CENTER OF EAST (REAR) GARAGE FOUNDATION WALL
Underslab Plumbing Inspection - Residential Passed 6/24/2021 6/24/2021 06/24/2021
All Rough Inspection - Residential Partial 7/22/2021 7/22/2021 07/22/2021
Misc
Informational
07/22/2021
: PFH GARAGE PORTAL FRAMING ONLY : OK TO COVER
All Rough Inspection - Residential Partial 9/22/2021 9/22/2021 09/22/2021
Misc
Informational
07/22/2021
: PFH GARAGE PORTAL FRAMING ONLY : OK TO COVER
Misc
Corrective Action Required
09/22/2021
2ND TRIP ALL ROUGH PORCH & PATIO ONLY OK TO COVER PORCH & PATIO
Sewer Service Inspection - R Passed 9/27/2021 (10:45) 9/27/2021 09/27/2021
Water Service Inspection - R Passed 9/28/2021 (11:15) 9/28/2021 09/28/2021
All Rough Inspection - Residential Failed 9/28/2021 9/28/2021 09/28/2021
Misc
Informational
09/22/2021
: PFH GARAGE PORTAL FRAMING ONLY : OK TO COVER
Misc
Corrective Action Required
09/22/2021
2ND TRIP ALL ROUGH PORCH & PATIO ONLY OK TO COVER PORCH & PATIO
Miscellaneous Correction
Corrective Action Required
09/28/2021
Seal upward penetration bed 2 closet Anchor bolts garage shall be in middle 1/3 the width of plate Tighten 5/8 anchor bolts garage portal Tighten anchor bolts garage Provide anchor bolt single car garage Seal upward penetration kitchen Seal fire block dead space bed # 5 Provide anchor bolts SCH 40 columns basement All wall outlets at garage to be 20 amp
All Rough Inspection - Residential Passed 10/6/2021 10/6/2021 10/06/2021
Misc
Informational
09/28/2021
: PFH GARAGE PORTAL FRAMING ONLY : OK TO COVER
Misc
Informational
10/06/2021
2ND TRIP ALL ROUGH PORCH & PATIO ONLY OK TO COVER PORCH & PATIO
Miscellaneous Correction
Resolved
10/06/2021
Gas Service Inspection - Residential Passed 10/6/2021 10/06/2021
Electrical Service Inspection Passed 10/6/2021 10/06/2021
Erosion Control Inspection Residential Failed 10/6/2021 10/06/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/17/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - SOIL STOCKPILES SHOULD NOT BE LOCATED NEAR THE STREET, STORM INLETS, LOT ACCESS, OR ADJACENT PROPERTY LINES. ALL STOCKPILES MUST EITHER BE STABILIZED, COVERED, OR HAVE ESC AND BMPs INSTALLED AROUND BASE OF THE PILE -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/06/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN GRAVEL FILTER AT DRIVEWAY - - CLEAN STREET & GUTTERS -
Driveway Inspection Partial 10/14/2021 10/14/2021 10/14/2021
Misc
Informational
10/14/2021
10-14-21 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 10/22/2021 10/22/2021 10/18/2021
Misc
Informational
10/14/2021
10-14-21 AN forms are in place and aggregate is present and compacted
Misc
Informational
10/18/2021
Driveway looks good and has expansion joints at curb and right of way. No sidewalk
Retaining Wall Inspection Passed 1/4/2022 01/04/2022
Plot Plan Inspection Passed 1/4/2022 01/04/2022
Occupancy Inspection - Codes Residential Failed 1/4/2022 1/4/2022 01/04/2022
Miscellaneous Correction
Corrective Action Required
01/04/2022
Garage requires 3 GFCI receptacles for 3 car garage Complete open GFCI box in garage Provide deadbolt self closing door Provide listed fixture or cover plate entry top of stairs ( open box) Repair broken window middle bedroom Provide handrail basement stairs Provide listed fixture or cover plate patio Provide flood light back yard open box soffit covered patio Land sewer tracer wire in a box at grade Provide splash blocks Sump shall discharge 36" from foundation wall Seal top of meter can, low volt exterior penetrations Provide 6" clearance wood siding to grade GFCI at AC condenser not working
Occupancy Inspection - Codes Residential Failed 1/18/2022 1/18/2022 01/18/2022
Miscellaneous Correction
Corrective Action Required
01/04/2022
Provide handrail basement stairs Provide listed fixture or cover plate patio Provide flood light back yard open box soffit covered patio Land sewer tracer wire in a box at grade Provide 6" clearance wood siding to grade
Occupancy Inspection - Codes Residential Full C of O 2/1/2022 2/1/2022 02/01/2022
Miscellaneous Correction
Resolved
02/01/2022
Documents & Images
Date Uploaded File Type Document Name
04/20/2021 Application Form APPLICATION
04/21/2021 LOT 62 FINAL
04/21/2021 W2 #62 - TRUSS LAYOUT
04/21/2021 W2 #62 - Riverside - Modern Farmhouse - F14x14C - Sheets- signed
04/21/2021 62 WOODSIDE RIDGE RETAINING WALL CALCULATION
04/21/2021 62 WOODISDE RIDGE RETAINING WALL CONSTRUCTION DRAWING
04/21/2021 W2 #62 - Retaining wall scope of work
04/21/2021 2704168 RF SEALS 04152021
04/22/2021 Approved Plans APPROVED PLANS
04/22/2021 Approved Plans APPROVED TRUSS DRAWINGS
04/22/2021 Approved Plans APPROVED TRUSS LAYOUT
04/22/2021 Plot Plan APPROVED PLOT PLAN
04/22/2021 62 WOODSIDE RIDGE RETAINING WALL DESIGN PACKAGE
04/22/2021 Approved Plans approved retaining wall drawings
04/23/2021 Receipt Receipt for transaction:2021-002181
04/23/2021 Letter DS Building Permit
05/17/2021 Lot 62 Woodside Ridge footing inspection
05/17/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
06/24/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
09/29/2021 103 NW Joshua drRWCALC Retaining wall
09/29/2021 103 NW Joshua driveRW1_1 Retaining wall
09/29/2021 Approved Plans approved retaining wall drawings
09/29/2021 Letter RETAINING WALL CALCS.
10/06/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/18/2021 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/04/2022 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
02/01/2022 Letter Field Certificate of Occupancy
02/01/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home