PRRES20211772
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT
04/14/2021
04/20/2021
01/21/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/16/2021 04/20/2021
Brandon Kalwei
Residential Plan Review Approved 04/16/2021 04/20/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $989.15 $989.15 Paid 04/20/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 04/20/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/20/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/20/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/20/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/20/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/17/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/17/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/17/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/17/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 01/05/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/14/2021 06/14/2021
Misc
Informational
06/14/2021
3RD PARTY FOOTING BY COLBY SHAW @ EVERSTEAD SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED CENTER OF REAR GARAGE WALL
Underslab Plumbing Inspection - Residential Passed 6/15/2021 6/15/2021 06/15/2021
All Rough Inspection - Residential Failed 9/10/2021 9/10/2021 09/10/2021
Miscellaneous Correction
Corrective Action Required
09/10/2021
: PFH PORTAL FRAMING ONLY : CITY APPROVED PLANS SHOW PFH @ SINGLE GARAGE DOOR ALSO, PLANS ON SITE DID NOT HAVE PAGE A4.0 WITH THIS DETAIL
Sewer Service Inspection - R Passed 9/17/2021 9/17/2021 09/17/2021
Electrical Service Inspection Passed 9/21/2021 9/21/2021 09/21/2021
Gas Service Inspection - Residential Passed 9/21/2021 9/21/2021 09/21/2021
All Rough Inspection - Residential Failed 9/21/2021 9/21/2021 09/21/2021
Miscellaneous Correction
Corrective Action Required
09/10/2021
**PROVIDE MIN 3/4” GRAVEL ST LOT ENTRANCE -Nail siding to sill plates per code -Frame and anchor 3rd garage PFH per detail -Complete b-vent chase and Fb as required -Protect dryer duct at top wall plate -Nail all CSPF walls sheathing per plan detail -Replace damaged cable to master bedroom light switch -Nail together the girder truss above rear dining per truss detail -Provide full support for rear porch roof beam at shelf/exterior wall -Brace interior walls per plan -Strap wall top plates lapped less than 24” at rear bedroom -Install hanger for truss connections to girder above front bedroom -Anchor basement columns -Provide ladder on site. Sill plates shall be anchored to foundation wall per code **DO NOT INSULATE
Water Service Inspection - R Passed 9/23/2021 (8:45) 9/23/2021 09/23/2021
All Rough Inspection - Residential Not Ready 9/29/2021 9/29/2021 09/29/2021
Miscellaneous Correction
Corrective Action Required
09/21/2021
**PROVIDE MIN 3/4” GRAVEL ST LOT ENTRANCE -Nail siding to sill plates per code -Frame and anchor 3rd garage PFH per detail -Complete b-vent chase and Fb as required -Protect dryer duct at top wall plate -Nail all CSPF walls sheathing per plan detail -Nail together the girder truss above rear dining per truss detail -Provide ladder on site. Sill plates shall be anchored to foundation wall per code **DO NOT INSULATE
All Rough Inspection - Residential Failed 10/1/2021 10/1/2021 10/01/2021
Miscellaneous Correction
Corrective Action Required
09/29/2021
-Frame and anchor 3rd garage PFH per detail ( ADDRESS MISSING 4200 LB HOLDDOWN DEVICES EMBEDDED INTO CONCRETE AND NAILED TO FRAMING PER PLAN S2.0 DETAIL 12 ) **DO NOT INSULATE
All Rough Inspection - Residential Not Ready 10/6/2021 10/6/2021 10/06/2021
Miscellaneous Correction
Corrective Action Required
10/01/2021
-Frame and anchor 3rd garage PFH per detail ( ADDRESS MISSING 4200 LB HOLDDOWN DEVICES EMBEDDED INTO CONCRETE AND NAILED TO FRAMING PER PLAN S2.0 DETAIL 12 ) - PROVIDE ENGINEER LETTER FOR HOLDDOWNS THAT NEED NUT & WASHER - : OK TO INSULATE LEAVE SINGLE CAR GARAGE PORTAL FRAME EXPOSED FOR INSPECTION OF HOLDDOWNS :
All Rough Inspection - Residential Not Ready 10/11/2021 10/11/2021 10/11/2021
Miscellaneous Correction
Corrective Action Required
10/06/2021
-Frame and anchor 3rd garage PFH per detail - INSTALL HDUS-SDS2.5 PER MANUFACTURES SPECIFICATIONS - ( ADDRESS MISSING 4200 LB HOLDDOWN DEVICES EMBEDDED INTO CONCRETE AND NAILED TO FRAMING PER PLAN S2.0 DETAIL 12 ) - HOLDDOWNS THAT NEED NUT & WASHER - : OK TO INSULATE LEAVE SINGLE CAR GARAGE PORTAL FRAME EXPOSED FOR INSPECTION OF HOLDDOWNS :
All Rough Inspection - Residential Not Ready 10/14/2021 10/14/2021 10/14/2021
Miscellaneous Correction
Corrective Action Required
10/11/2021
-Frame and anchor 3rd garage PFH per detail - INSTALL HDUS-SDS2.5 PER MANUFACTURES SPECIFICATIONS - ( ADDRESS MISSING 4200 LB HOLDDOWN DEVICES EMBEDDED INTO CONCRETE AND NAILED TO FRAMING PER PLAN S2.0 DETAIL 12 ) - HOLDDOWNS THAT NEED NUT & WASHER - : OK TO INSULATE LEAVE SINGLE CAR GARAGE PORTAL FRAME EXPOSED FOR INSPECTION OF HOLDDOWNS :
Misc
Corrective Action Required
10/14/2021
*10-14-21 HOLD DOWNS AT GARAGE PORTAL STILL DO NOT HAVE NUTS ON THEM. THIS IS THE 7th ALL ROUGH INSPECTION -NOT READY FEE ASSESSED AGAIN
All Rough Inspection - Residential Passed 10/18/2021 10/18/2021 10/18/2021
Miscellaneous Correction
Resolved
10/18/2021
Misc
Resolved
10/18/2021
Driveway Inspection Partial 11/3/2021 11/3/2021 11/03/2021
Misc
Informational
11/03/2021
Driveway is framed up and has aggregate in place and compacted. Meets LS and ADA specs. 11/3 ES
Sidewalk Inspection Partial 11/8/2021 11/8/2021 11/08/2021
Misc
Informational
11/08/2021
Sidewalk is framed in, has aggregate in place and compacted. Meets LS and ADA spec. 11/8 ES
Sidewalk Inspection Passed 11/12/2021 11/12/2021 11/12/2021
Misc
Informational
11/08/2021
Sidewalk is framed in, has aggregate in place and compacted. Meets LS and ADA spec. 11/8 ES
Misc
Informational
11/12/2021
Sidewalk meets LS and ADA spec. 11/12 ES
Driveway Inspection Failed 11/12/2021 11/12/2021 11/12/2021
Misc
Informational
11/03/2021
Driveway is framed up and has aggregate in place and compacted. Meets LS and ADA specs. 11/3 ES
Misc
Corrective Action Required
11/12/2021
Driveway approach is out of tolerance through the 5’ sidewalk lane and doesn’t meet LS/ADA spec. Need to remove and replace. 11/12 ES
Plot Plan Inspection Passed 1/3/2022 01/03/2022
Occupancy Inspection - Codes Residential Failed 1/3/2022 1/3/2022 01/03/2022
Miscellaneous Correction
Corrective Action Required
01/03/2022
Driveway inspection still pending Pay outstanding fees Obtain lawn irrigation permit & submit back-flow certification Cap DWV stub outs basement Complete drain master shower Repair drywall at self closing garage door Insulate floor joist cavities at foundation and seal plate ( exterior thermal envelope) Seal top of exterior light fixtures garage Provide guardrail at patio where over 30" to grade Seal gas line near meter can, top of meter can, ac disconnect Sump pump shall discharge 36" from foundation wall
Occupancy Inspection - Codes Residential Failed 1/6/2022 1/6/2022 01/06/2022
Miscellaneous Correction
Corrective Action Required
01/03/2022
Driveway inspection still pending Obtain lawn irrigation permit & submit back-flow certification Insulate floor joist cavities at foundation and sole plate ( exterior thermal envelope)
Occupancy Inspection - Codes Residential Temporary C of O 1/11/2022 1/11/2022 01/11/2022
Miscellaneous Correction
Corrective Action Required
01/06/2022
Driveway inspection still pending
Driveway Inspection Passed 1/21/2022 1/21/2022 01/21/2022
Misc
Informational
11/12/2021
Driveway is framed up and has aggregate in place and compacted. Meets LS and ADA specs. 11/3 ES
Misc
Corrective Action Required
11/12/2021
Driveway approach is out of tolerance through the 5’ sidewalk lane and doesn’t meet LS/ADA spec. Need to remove and replace. 11/12 ES
Misc
Informational
01/21/2022
New approach meets LS and ADA specs. RP 1-21-22
Occupancy Inspection - Codes Residential Full C of O 1/21/2022 01/21/2022
Miscellaneous Correction
Resolved
01/21/2022
Documents & Images
Date Uploaded File Type Document Name
04/14/2021 Application Form APPLICATION
04/14/2021 87 WOODSIDE RIDGE ROOF LAYOUT
04/14/2021 W0 #87 - Sheffield - Mediterranean - Sheets- signed
04/14/2021 210361
04/14/2021 Application Form APPROVED PLANS
04/14/2021 Application Form APPROVED TRUSS DRAWINGS
04/14/2021 Application Form APPROVED TRUSS LAYOUT
04/20/2021 LOT 87 FINAL
04/20/2021 Plot Plan APPROVED PLOT PLAN
04/20/2021 Receipt Receipt for transaction:2021-002073
04/20/2021 Letter DS Building Permit
06/10/2021 Lot 87 Woodside Ridge Footing Inspection
06/10/2021 87 Woodside Ridge Subgrade
06/14/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/08/2021 87 Woodside Ridge PFH holdown device letter
10/11/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/17/2021 Receipt Receipt for transaction:2021-008037
10/18/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/12/2021 Letter INSPECTION SUMMARY
11/12/2021 Letter INSPECTION SUMMARY
01/03/2022 Letter INSPECTION SUMMARY
01/03/2022 Letter INSPECTION SUMMARY
01/05/2022 Receipt Receipt for transaction:2022-000081
01/06/2022 Letter INSPECTION SUMMARY
01/10/2022 314 NW Ambersham Dr Backflow
01/11/2022 Letter Codes Temporary Certificate of Occupancy
01/21/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter Field Certificate of Occupancy
01/21/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home