Permit Application Status

PRRES20211584


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211584
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT
04/06/2021
04/07/2021
01/06/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/08/2021 04/06/2021
Brandon Kalwei
Residential Plan Review Approved 04/08/2021 04/06/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,500.03 $1,500.03 Paid 04/07/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 04/07/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/07/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/07/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/07/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/07/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/22/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 12/22/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/29/2021 04/29/2021
Misc
Informational
04/29/2021
UFER FOUNDATION WALL REAR OF GARAGE
Underslab Plumbing Inspection - Residential Passed 6/10/2021 6/10/2021 06/10/2021
All Rough Inspection - Residential Partial 7/9/2021 7/12/2021 07/12/2021
Misc
Informational
07/12/2021
-7/12/21 OK TO COVER GARAGE PORTAL AND COVERED PORCH
Sewer Service Inspection - R Passed 7/28/2021 (8:30) 7/28/2021 07/28/2021
Water Service Inspection - R Passed 7/29/2021 (11:30) 7/29/2021 07/29/2021
All Rough Inspection - Residential Failed 9/21/2021 9/21/2021 09/21/2021
Misc
Informational
07/12/2021
-7/12/21 OK TO COVER GARAGE PORTAL AND COVERED PORCH
Miscellaneous Correction
Corrective Action Required
09/21/2021
-PROVIDE CITY APPROVED, STAMPED PLANS FOR INSPECTION
All Rough Inspection - Residential Failed 9/22/2021 9/22/2021 09/22/2021
Misc
Informational
09/21/2021
-7/12/21 OK TO COVER GARAGE PORTAL AND COVERED PORCH
Miscellaneous Correction
Corrective Action Required
09/21/2021
-PROVIDE CITY APPROVED, STAMPED PLANS FOR INSPECTION
Miscellaneous Correction
Corrective Action Required
09/22/2021
Fire block both dead space master bed/closet Seal gap at double top plate master shower Provide 4 studs at GT bearing point closet near laundry Provide mid point support vertical DWV 2" & smaller Seal fire blocking HVAC chase laundry Seal fire blocking dead space bed #2 Replace stud bed #2 closet Seal upward penetrations at fireplace Seal fire blocking above fireplace Fire block & seal both dead spaces in great room Complete HVAC in chase near SGD Provide joist hanger at (4) LVLs bath #4 Fire blocking at soffit bath #4 Seal upward penetration bath #4 Seal top of furr out at shower bath #4 Fire block / insulate DWV bath # 4 /garage Address notched joist bath #4 Complete HVAC in chase bath #4 Nail studs at intersecting wall corners per code Double every other joist per plan garage chase at 20 min door Fire block / insulate DWV Nail LIBs throughput Provide protection plate sump discharge stair landing Provide joist hangers basement near stairs Nail off joist hanger at LVL near stairs Address triple floor joist at missing cantilever under fireplace Identify ufer ground with green tape both ends Nail exterior wall sheathing per code
All Rough Inspection - Residential Not Ready 9/28/2021 9/28/2021 09/28/2021
Misc
Informational
09/22/2021
-7/12/21 OK TO COVER GARAGE PORTAL AND COVERED PORCH
Miscellaneous Correction
Resolved
09/28/2021
-PROVIDE CITY APPROVED, STAMPED PLANS FOR INSPECTION
Miscellaneous Correction
Corrective Action Required
09/22/2021
Fire block & seal both dead spaces in great room ( near SGD HVAC & DWV ) Fire block / insulate DWV bath # 4 /garage ( missed one near mud room ) Nail studs at intersecting wall corners per code Nail off joist hanger at LVL near stairs Nail exterior wall sheathing per code
All Rough Inspection - Residential Passed 9/29/2021 9/29/2021 09/29/2021
Misc
Informational
09/28/2021
-7/12/21 OK TO COVER GARAGE PORTAL AND COVERED PORCH
Miscellaneous Correction
Resolved
09/29/2021
Driveway Inspection Partial 10/7/2021 10/7/2021 10/07/2021
Misc
Informational
10/07/2021
10-7-21 10:48 AN Forms are in place and aggregate is present and compacted.
Driveway Inspection Passed 10/15/2021 10/15/2021 10/12/2021
Misc
Informational
10/07/2021
10-7-21 10:48 AN Forms are in place and aggregate is present and compacted.
Misc
Informational
10/12/2021
10-12-21 AN driveway looks good and has expansion joints at curb and right of way. No sidewalk
Electrical Service Inspection Passed 10/13/2021 10/13/2021 10/13/2021
Gas Service Inspection - Residential Passed 10/13/2021 10/13/2021 10/13/2021
Erosion Control Inspection Residential Failed 10/13/2021 10/13/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/13/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - CLEAN STREET -
Occupancy Inspection - Codes Residential Not Ready 12/13/2021 12/13/2021 12/13/2021
Misc
Corrective Action Required
12/13/2021
NO INSPECTION PROVIDE ADDRESS
Occupancy Inspection - Codes Residential Failed 12/14/2021 12/14/2021 12/14/2021
Misc
Corrective Action Required
12/13/2021
Pay not ready fees Driveway at 3rd car garage not per plot plan Handrail lower stairs basement shall be 34"-38" Complete gutters/downspouts at front stoop Provide splash blocks 36" from foundation Sump shall discharge 36" from foundation Seal top of meter can & ac disconnect
Plot Plan Inspection Passed 12/20/2021 12/20/2021
Occupancy Inspection - Codes Residential Temporary C of O 12/20/2021 12/20/2021 12/20/2021
Misc
Corrective Action Required
12/14/2021
Pay not ready fees Driveway at 3rd car garage not per plot plan Complete gutters/downspouts at front stoop Sump shall discharge 36" from foundation Land sewer tracer wire in a box at grade
Occupancy Inspection - Codes Residential Full C of O 1/6/2022 1/6/2022 01/06/2022
Misc
Resolved
01/06/2022
Documents & Images
Date Uploaded File Type Document Name
04/06/2021 Application Form APPLICATION
04/06/2021 116 WOODSIDE RIDGE TRUSS LAYOUT
04/06/2021 210328
04/06/2021 W0 #116 - Winchester - Modern Farmhouse - Sheets- signed
04/06/2021 LOT 116 FINAL
04/06/2021 Approved Plans APPROVED PLANS
04/06/2021 Approved Plans APPROVED TRUSS DRAWINGS
04/06/2021 Approved Plans APPROVED TRUSS LAYOUT
04/07/2021 Receipt Receipt for transaction:2021-001795
04/07/2021 Letter DS Building Permit
04/29/2021 Letter INSPECTION SUMMARY
04/29/2021 116 Woodside Ridge Subgrade
06/10/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
09/23/2021 Approved Plans APPROVED FLOOR JOIST REVISION
09/24/2021 116 Woodside Ridge notched floor joist letter
09/28/2021 Letter INSPECTION SUMMARY
09/29/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/12/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter Codes Temporary Certificate of Occupancy
12/22/2021 Receipt Receipt for transaction:2021-009441
12/29/2021 Plot Plan APPROVED AS GRADED PLOT PLAN
01/06/2022 Letter Codes Final Certificate of Occupancy
01/06/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home