Summary
PRRES20211438
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
03/30/2021
03/31/2021
03/04/2022
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
LOREN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 04/02/2021 03/31/2021
Shannon McGuire
Plot Plan Review Approved 04/01/2021 03/31/2021
Kim Brennan
Residential Plan Review Approved 04/01/2021 03/31/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $959.79 $959.79 Paid 03/31/2021
Right of Way Permit Fee $80.00 $80.00 Paid 03/31/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/31/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 03/31/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 03/31/2021
Water Meter Fee $455.54 $455.54 Paid 03/31/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 01/13/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/28/2021 5/28/2021 05/28/2021
Underslab Plumbing Inspection - Residential Passed 6/22/2021 6/22/2021 06/22/2021
All Rough Inspection - Residential Partial 8/9/2021 8/9/2021 08/09/2021
Misc
Informational
08/09/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Sewer Service Inspection - R Passed 8/31/2021 (8:00) 8/31/2021 08/31/2021
Water Service Inspection - R Passed 8/31/2021 8/31/2021 08/31/2021
Erosion Control Inspection Residential Failed 8/31/2021 8/31/2021 08/31/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/31/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Not Ready 9/28/2021 9/28/2021 09/28/2021
Misc
Informational
08/09/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
09/28/2021
INSPECTION DENIED CITY APPROVED TRUSS PLANS ARE REQUIRED ON SITE WITH HOUSE PLANS FOR INSPECTION
All Rough Inspection - Residential Failed 9/30/2021 9/30/2021 09/30/2021
Misc
Informational
09/28/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
09/28/2021
-Anchor bolts required within 12” of plate break at garage -Protection plates at all NM within 1 1/4” end of stud-see garage -Add stud shoe at stud bored for SER cable garage -Seal all top plate penetrations - see garage -Secure all vertical DWV 2” or less at mid point -secure gas flex line at fireplace -Address damaged trusses above garage entry and pantry (4) trusses T10A, T11, T10B and (2) trusses at foyer/great room T7 and T8 -Engineer letter required from truss manufacturer -Truss hanger per plans dbl truss girder master bedroom -seal unused top plate penetration at great room, front bath -missing stud master water closet wall, 16” oc per plans -(1) ply of dbl girder truss not supported by wall along foyer/great room/master bed entry at bearing end, truss H2.5 hold downs required for girder -Truss H2.5 clip required at hip truss master bedroom -Exterior bracing CS-PF design per plans at dining room sliding glass door -Truss H2.5 hold downs required at covered porch trusses -Rafter ties or H2.5 clips at covered porch rafters per plans -Anchor all SCH 40 columns to floor in basement -Min (1) receptacle required at unfinished basement and must be within 25’ of furnace -Nail exterior sheathing per plans
Electrical Service Inspection Passed 9/30/2021 9/30/2021 09/30/2021
Gas Service Inspection - Residential Passed 9/30/2021 9/30/2021 09/30/2021
All Rough Inspection - Residential Failed 10/13/2021 10/13/2021 10/13/2021
Misc
Informational
09/30/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
09/30/2021
-Anchor bolts required within 12” of plate break at garage -see sgl car garage East side at door -Add stud shoe at stud bored for SER cable garage - nail stud shoe complete -Address damaged trusses above garage entry and pantry (4) trusses T10A, T11, T10B and (2) trusses at foyer/great room T7 and T8 -Engineer letter required from truss manufacturer -Exterior bracing CS-PF design per plans at dining room sliding glass door -nail sheathing per plans -Rafter ties or H2.5 clips at covered porch rafters per plans -rafter ties are installed in the bottom third of the rafter, see R802.5.2 -Nail exterior sheathing per plans
All Rough Inspection - Residential Passed 10/18/2021 10/18/2021 10/18/2021
Misc
Resolved
10/18/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Resolved
10/18/2021
Driveway Inspection Passed 11/9/2021 11/9/2021 11/09/2021
Misc
Informational
11/09/2021
On Tuesday, 11-09-2021. A drive approach inspection was completed and passed for concrete placement.
Sidewalk Inspection Passed 11/9/2021 11/9/2021 11/09/2021
Misc
Informational
11/09/2021
On Tuesday, 11-09-2021. A sidewalk inspection was completed and placed for concrete placement.
Piers/Caissons Inspection - Residential Passed 1/5/2022 01/05/2022
Misc
Informational
01/05/2022
addressed in 3rd party footing inspection report.
Occupancy Inspection - Codes Residential Failed 1/5/2022 1/5/2022 01/05/2022
Misc
Corrective Action Required
01/05/2022
-anti siphon device set screw sheered off -final grade and sod -splash block and sump pump discharge to be 36” from foundation -check water meter at time of final grade and sod
Occupancy Inspection - Codes Residential Temporary C of O 1/11/2022 1/11/2022 01/11/2022
Misc
Corrective Action Required
01/05/2022
-resolve outstanding inspection fee before final c of o -final grade and sod -splash block and sump pump discharge to be 36” from foundation -check water meter at time of final grade and sod **OK FOR TCO - TCO EXPIRES 3/11/22**
Plot Plan Inspection Passed 3/4/2022 03/04/2022
Occupancy Inspection - Codes Residential Full C of O 3/4/2022 3/4/2022 03/04/2022
Misc
Resolved
03/04/2022
-resolve outstanding inspection fee before final c of o -final grade and sod -splash block and sump pump discharge to be 36” from foundation -check water meter at time of final grade and sod **OK FOR TCO - TCO EXPIRES 3/11/22**
Documents & Images
Date Uploaded File Type Document Name
03/30/2021 Application Form Permit Application and License Tax Form
03/31/2021 Approved Plans Approved Drawings
03/31/2021 Approved Plans Approved Truss Layout
03/31/2021 Approved Plans Approved Truss Package
03/31/2021 Plot Plan Approved Plot Plan
03/31/2021 Receipt Receipt for transaction:2021-001640
03/31/2021 Letter DS Building Permit
05/28/2021 Lot 92 Hawthorn Ridge Footing inspection
05/28/2021 Letter INSPECTION SUMMARY
06/22/2021 Letter INSPECTION SUMMARY
08/09/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
08/31/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
10/12/2021 Approved Plans Approved Truss Revisions
10/13/2021 Letter INSPECTION SUMMARY
10/18/2021 Letter INSPECTION SUMMARY
11/09/2021 Letter INSPECTION SUMMARY
11/09/2021 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/05/2022 Letter INSPECTION SUMMARY
01/11/2022 Letter Codes Temporary Certificate of Occupancy
01/13/2022 Receipt Receipt for transaction:2022-000240
03/04/2022 Letter Codes Final Certificate of Occupancy
03/04/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home