Permit Application Status

PRRES20210754


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210754
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
02/24/2021
02/25/2021
08/23/2021
12/03/2021
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
CORY@JFECONSTRUCTION.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/01/2021 02/25/2021
Kim Brennan
Deck location
Corrective Action Required
02/25/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
02/25/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. Per the revised MDP, no MLO's are shown for the front left or front right elevations
Residential Plan Review Approved 03/01/2021 02/25/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
02/25/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) Not shown in unfinished basement
Plot Plan Review Rejected 02/26/2021 02/24/2021
Kim Brennan
Deck location
Corrective Action Required
02/24/2021

Deck location, with dimensions to property lines must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
02/24/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. Per the revised MDP, no MLO's are shown for the front left or front right elevations
Planning Review (RES) Rejected 02/26/2021 02/24/2021
Shannon McGuire
Miscellaneous Correction
Corrective Action Required
02/24/2021

Please label all exterior material for the proposed building.
Residential Plan Review Rejected 02/26/2021 02/24/2021
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
02/24/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) Not shown in unfinished basement
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,761.65 $1,761.65 Paid 02/25/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/25/2021
Right of Way Permit Fee $80.00 $80.00 Paid 02/25/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 02/25/2021
Water Meter Fee $455.54 $455.54 Paid 02/25/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 02/25/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 3/9/2021 (1:30) 3/9/2021 03/09/2021
Misc
Corrective Action Required
03/09/2021
- ALL REINFORCEMENT SHALL BE LAPPED A MIN OF 24" AT ENDS SPLICES AND AROUND CORNERS ( NEAR UFER 16") - -CHAIR UP #4 AT STEPDOWN FRONT OF GARAGE NEAR FRONT STOOP - - UFER NORTH FOUNDATION WALL BEHIND GARAGE -
Footing Inspection - Residential Passed 3/10/2021 (8:00) 3/9/2021 03/09/2021
Misc
Resolved
03/09/2021
- PROVIDE ADDRESS - - UFER NORTH FOUNDATION WALL BEHIND GARAGE -
Underslab Plumbing Inspection - Residential Passed 3/22/2021 03/22/2021
Sewer Service Inspection - R Passed 3/26/2021 (11:00) 3/26/2021 03/26/2021
Water Service Inspection - R Passed 3/31/2021 (10:45) 3/31/2021 03/31/2021
Piers/Caissons Inspection - Residential Passed 4/19/2021 04/19/2021
Misc
Informational
04/19/2021
- 3RD PARTY PIERS BY KEVIN MILLER @ APEX SIGNED & SEALED BY CLAYTON HESS - (3) 24 X 36
All Rough Inspection - Residential Partial 5/3/2021 5/3/2021 05/03/2021
Misc
Informational
05/03/2021
PFH GARAGE PORTAL FRAMING ONLY HOLDDOWNS, NAILING PATTERN OK TO COVER EXTERIOR
Gas Service Inspection - Residential Failed 6/30/2021 6/30/2021 06/30/2021
Misc
Corrective Action Required
06/30/2021
PROVIDE MIN 10 PSI FOR 15 MINUTES
Electrical Service Inspection Failed 6/30/2021 6/30/2021 06/30/2021
Misc
Corrective Action Required
06/30/2021
IDENTIFY UFER GROUND ( GREEN TAPE )
All Rough Inspection - Residential Failed 6/30/2021 6/30/2021 06/30/2021
Misc
Informational
05/03/2021
PFH GARAGE PORTAL FRAMING ONLY HOLDDOWNS, NAILING PATTERN OK TO COVER EXTERIOR
Misc
Corrective Action Required
06/30/2021
Provide anchor bolt within 12" of plate break rear wall basement Tighten anchor bolts basement Seal exterior &'upward penetrations south basement wall Seal upward penetrations above cooktop Seal return air bores at cooktops Seal top plate penetrations at coffee bar Provide CS-PF at SGD at deck per plan Double rafter to align w/ fire place on deck per pl Support pex master shower Solid block & nail sheathing per code garage at front porch Seal top plate penetration bed #3
Electrical Service Inspection Passed 7/8/2021 7/8/2021 07/08/2021
Misc
Resolved
07/08/2021
Gas Service Inspection - Residential Passed 7/8/2021 7/8/2021 07/08/2021
Misc
Resolved
07/08/2021
PROVIDE MIN 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Passed 7/8/2021 7/8/2021 07/08/2021
Misc
Informational
06/30/2021
PFH GARAGE PORTAL FRAMING ONLY HOLDDOWNS, NAILING PATTERN OK TO COVER EXTERIOR
Misc
Resolved
07/08/2021
Driveway Inspection Partial 8/11/2021 8/11/2021 08/11/2021
Misc
Informational
08/11/2021
Forms were placed and aggregate was present and compacted. Driveway is 33 feet wide. RP 8-11-21
Driveway Inspection Passed 8/20/2021 8/20/2021 08/20/2021
Misc
Informational
08/11/2021
Forms were placed and aggregate was present and compacted. Driveway is 33 feet wide. RP 8-11-21
Misc
Informational
08/20/2021
Finished driveway meets LS specs. RP 8-20-21
Occupancy Inspection - Codes Residential Failed 11/18/2021 11/18/2021 11/18/2021
Miscellaneous Correction
Corrective Action Required
11/18/2021
- Erosion control, swaddles in front and gravel in street - obtain a sprinkler permit and back flow certification - Final grading and sod - 36” splash blocks or finish pop ups - master bath, light 4’ from tub. Minimum 8’ -water hammer preventer for dishwasher - lock and secondary lock for sliding door -vent against expansion tank on water heater - M1502.4.5.1 Dryer vent length max 35’ you have 21’ straight with 4 x 90s =41’
Piers/Caissons Inspection - Residential Passed 12/3/2021 12/03/2021
Misc
Informational
12/03/2021
3rd party inspection
Erosion Control Inspection Residential Passed 12/3/2021 12/03/2021
Plot Plan Inspection Passed 12/3/2021 12/03/2021
Occupancy Inspection - Codes Residential Full C of O 12/3/2021 12/3/2021 12/03/2021
Miscellaneous Correction
Resolved
12/03/2021
- Erosion control, swaddles in front and gravel in street - obtain a sprinkler permit and back flow certification - Final grading and sod - 36” splash blocks or finish pop ups - master bath, light 4’ from tub. Minimum 8’ -water hammer preventer for dishwasher - lock and secondary lock for sliding door -vent against expansion tank on water heater - M1502.4.5.1 Dryer vent length max 35’ you have 21’ straight with 4 x 90s =41’
Documents & Images
Date Uploaded File Type Document Name
02/24/2021 Application Form Permit Application
02/24/2021 Application Form License Tax Form
02/24/2021 Letter Codes Residential Plan Review
02/24/2021 Plot Plan Approved Plot Plan
02/25/2021 Approved Plans Approved Drawings
02/25/2021 Receipt Receipt for transaction:2021-000920
02/25/2021 Letter DS Building Permit
03/09/2021 Letter INSPECTION SUMMARY
03/09/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter INSPECTION SUMMARY
03/31/2021 Letter INSPECTION SUMMARY
04/18/2021 Final_2021_04_13_GBSlab_LSMO_Concrete Design
04/19/2021 Letter INSPECTION SUMMARY
05/03/2021 Letter INSPECTION SUMMARY
06/30/2021 Letter INSPECTION SUMMARY
06/30/2021 Letter INSPECTION SUMMARY
06/30/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
08/11/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
11/18/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter Field Certificate of Occupancy
12/03/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home