Summary
PRRES20210625
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - COVERED PATIO
02/16/2021
02/18/2021
05/16/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/19/2021 02/17/2021
Brandon Kalwei
Residential Plan Review Approved 02/19/2021 02/17/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $875.22 $875.22 Paid 02/18/2021
8331507-Sewer Connection Fee $390.00 $390.00 Paid 02/18/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/18/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/18/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/18/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/18/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 04/28/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/11/2021 05/11/2021
Misc
Informational
05/11/2021
3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED CENTER RIGHT OF NORTH (REAR) GARAGE FOUNDATION WALL
Erosion Control Inspection Residential Failed 5/27/2021 05/27/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/27/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
Underslab Plumbing Inspection - Residential Passed 5/27/2021 5/27/2021 05/27/2021
All Rough Inspection - Residential Failed 8/31/2021 8/31/2021 08/31/2021
Miscellaneous Correction
Corrective Action Required
08/31/2021
: PFH Garage portal frame only FAIL : PFH garage portal frame Sheet S2.0 detail 12 Spliced edges in exterior wall sheathing shall occur over and be nailed to common blocking within middle 24" of wall one row of 3" OC nailing is required in each panel edge Fasten top plate to header with two rows of 16d sinker nails at 3" OC Anchor bolts shall be in middle 1/3 the width of plate Nail exterior wall sheathing per plan Sheet S1.0 ( no staples) Covers patio covered unable to verify trusses or hangers expose for inspection Covered porch covered unable to verify trusses or hangers expose for inspection
Sewer Service Inspection - R Passed 9/13/2021 09/13/2021
Water Service Inspection - R Passed 9/14/2021 (1:30) 9/14/2021 09/14/2021
Gas Service Inspection - Residential Passed 10/25/2021 10/25/2021 10/25/2021
Electrical Service Inspection Failed 11/3/2021 11/3/2021 11/03/2021
Miscellaneous Correction
Corrective Action Required
11/03/2021
IDENTIFY UFER GROUND AR SERVICE PANEL ( GREEN TAPE )
All Rough Inspection - Residential Failed 11/3/2021 11/3/2021 11/03/2021
Miscellaneous Correction
Corrective Action Required
08/31/2021
: PFH Garage portal frame only FAIL : PFH garage portal frame Sheet S2.0 detail 12 Anchor bolts shall be in middle 1/3 the width of plate
Miscellaneous Correction
Corrective Action Required
11/03/2021
Provide LUS24 hangers girder truss B1 garage per truss plans Provide 4 stud pack at girder truss bearing points throughput per roof plan Nail studs at intersecting wall corners per plan Provide 5/8!anchor bolt in middle 1/3 the width of plate PFH portal frame garage Tighten anchor bolts garage Provide anchor bolt end of plate east wall garage Solid block soffit top plate to roof deck & seal gaps west garage wall Furr out HVAC ducts in garage to allow for insulation Provide LUS24 hanger truss D1 bed 2 per truss plans Provide H2.5s @ dbl girder truss corner dining/great room Strap top plate SW corner bed 2 no plate overlap Seal fire blocking dead space next to refrigerator & above Seal upward penetration bottom plate kitchen Provide CS-PF nailing pattern & straps SGD & dining room windows Fire block fireplace Solid block & nail shearing breaks both sides fireplace Strap top plate master bedroom near tub Strap top plate corner master closet no plate overlap Seal duct between furnace & foundation wall Provide anchor bolts SCH 40 columns basement
Electrical Service Inspection Passed 11/17/2021 11/17/2021 11/17/2021
Miscellaneous Correction
Resolved
11/17/2021
All Rough Inspection - Residential Not Ready 11/17/2021 11/17/2021 11/17/2021
Miscellaneous Correction
Resolved
11/17/2021
Miscellaneous Correction
Corrective Action Required
11/03/2021
Provide LUS24 hanger girder truss B1 garage per truss plans ( east wall near front porch ) Provide 4 stud pack at girder truss bearing points throughput per roof plan ( west garage wall ) Nail studs at intersecting wall corners per plan ( bed # 2 near front porch ) Provide CS-PF nailing pattern SGD & dining room windows 3" GRID PATTERN ( 2018 IRC FIGURE R602.10.6.4 )
All Rough Inspection - Residential Passed 11/18/2021 11/18/2021 11/18/2021
Miscellaneous Correction
Resolved
11/18/2021
Driveway Inspection Partial 12/15/2021 12/15/2021
Misc
Informational
12/15/2021
Forms were placed and aggregate was present and compacted. RP 12-15-21
Driveway Inspection Passed 12/22/2021 12/22/2021 12/22/2021
Misc
Informational
12/15/2021
Forms were placed and aggregate was present and compacted. RP 12-15-21
Misc
Informational
12/22/2021
Driveway meets LS specs. 12/22/21 ES
Piers/Caissons Inspection - Residential Passed 4/11/2022 04/11/2022
Misc
Informational
04/11/2022
3rd party on footing inspection
Erosion Control Inspection Residential Failed 4/11/2022 04/11/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/27/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER CLEAN STREET
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/11/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL MAINTAIN SILT FENCE UNTIL SOD COMPLETE CLEAN STREET
Occupancy Inspection - Codes Residential Failed 4/11/2022 4/11/2022 04/11/2022
Miscellaneous Correction
Corrective Action Required
04/11/2022
Provide final grade Provide sod Remove dust covers smoke detector Provide clamp at AC whip Sump shall discharge 36" from foundation Sewer tracer wire shall be in a box at grade level
Plot Plan Inspection Passed 4/28/2022 04/28/2022
Occupancy Inspection - Codes Residential Temporary C of O 4/28/2022 4/28/2022 04/28/2022
Miscellaneous Correction
Corrective Action Required
04/11/2022
PAY NOT READY FEE OBTAIN LAWN IRRIGATION PERMIT & SUBMIT BACK FLOW CERTIFICATION :TCO EXPIRES 5/27/22 :
Occupancy Inspection - Codes Residential Full C of O 5/16/2022 5/16/2022 05/16/2022
Miscellaneous Correction
Resolved
05/16/2022
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home