Permit Application Status

PRRES20210596


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210596
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - UNFINISHED BASEMENT - COVERED PATIO
02/12/2021
02/18/2021
04/14/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/17/2021 02/16/2021
Brandon Kalwei
Residential Plan Review Approved 02/17/2021 02/16/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/18/2021
9110078-Valuation Fee New Single Family $1,070.52 $1,070.52 Paid 02/18/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/18/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 02/18/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/18/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/18/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/17/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 4/12/2021 (1:00) 4/12/2021 04/12/2021
Misc
Corrective Action Required
04/12/2021
Not per city approved plans
Footing Inspection - Residential Passed 4/23/2021 04/23/2021
Misc
Resolved
04/23/2021
Not per city approved plans
Misc
Informational
04/23/2021
3RD PARTY FOOTING BY COLBY SHAW @ RES SIGNED & SEALED BY BRADLEY HUXOL UFER LOCATED REAR GARAGE WALL NEAR NE CORNER
Erosion Control Inspection Residential Failed 5/26/2021 05/26/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/26/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE CLEAN GRAVEL FROM STREET
Underslab Plumbing Inspection - Residential Passed 5/26/2021 5/26/2021 05/26/2021
Erosion Control Inspection Residential Failed 9/2/2021 09/02/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/26/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE CLEAN GRAVEL FROM STREET
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/02/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN GUTTER BUDDY AT CURB INLET & REMOVE SEDIMENT BUILD UP -
Electrical Service Inspection Passed 9/2/2021 9/2/2021 09/02/2021
Gas Service Inspection - Residential Failed 9/2/2021 9/2/2021 09/02/2021
Miscellaneous Correction
Corrective Action Required
09/02/2021
PROVIDE MIN 10 PSI FOR 10 MINUTES ONLY 4 PSI
All Rough Inspection - Residential Failed 9/2/2021 9/2/2021 09/02/2021
Miscellaneous Correction
Corrective Action Required
09/02/2021
Tighten anchor bolts garage Provide CS-PF nailing at SGD per plan Seal fire blocking above fireplace Provide boca plate ice maker line Provide H2.5 or truss lock screws covered patio trusses Provide nails in LTHJA26 hanger bed 1 closet &. Single car garage Provide LUS24 hangers per truss plans at M3 trusses Provide solid blocking at sheathing break & nail per code left of kitchen window Nail exterior wall sheathing corner at kitchen sink & bed #1 near window & dining ='throughput Provide min 4 studs below each girder truss bearing point per roof plan Strap cut top plate bed #2 interior load bearing wall Nail LIBs per code Seal exterior penetrations bed #3 closet Complete pyro-guard to top plate bed #3, at HVAC line set & garage Provide joist hangers above service panel
All Rough Inspection - Residential Failed 9/9/2021 9/9/2021 09/09/2021
Miscellaneous Correction
Corrective Action Required
09/02/2021
-Seal fire blocking above fireplace-SEAL GAPS -Provide LUS24 hangers per truss plans at M3 trusses-MASTER BATH WC -Provide solid blocking at sheathing break & nail per code left of kitchen window-BOT COMPLETE -Nail exterior wall sheathing corner at kitchen sink & bed #1 near window & dining ='throughout-DINING NOT DONE, KITCHEN/BED ONE NAILS NOT IN FRAMING,GARAGE INCOMPLETE, ETC.-SEE PLANS FOR ALL BRACED WALL LOCATIONS AND COMPLETE NAILING PATTERN -Provide min 4 studs below each girder truss bearing point per roof plan-GARAGE WALL -Strap cut top plate bed #2 interior load bearing wall -BOTH SIDES -Seal exterior penetrations bed #3 closet -Complete pyro-guard to top plate bed #3, at HVAC line set & garage-NOT COMPLETE
Gas Service Inspection - Residential Passed 9/9/2021 9/9/2021 09/09/2021
Miscellaneous Correction
Resolved
09/09/2021
PROVIDE MIN 10 PSI FOR 10 MINUTES ONLY 4 PSI
Sewer Service Inspection - R Passed 9/14/2021 09/14/2021
Water Service Inspection - R Passed 9/16/2021 (8:45) 9/16/2021 09/16/2021
Erosion Control Inspection Residential Failed 9/16/2021 09/16/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/02/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE CLEAN GRAVEL FROM STREET
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/02/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN GUTTER BUDDY AT CURB INLET & REMOVE SEDIMENT BUILD UP -
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/16/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - MAINTAIN SILT FENCE - - REMOVE TRASH & SEDIMENT BUILD UP AT CURB INLET -
All Rough Inspection - Residential Not Ready 9/16/2021 9/16/2021 09/16/2021
Miscellaneous Correction
Corrective Action Required
09/09/2021
-Provide solid blocking at sheathing break & nail per code left of kitchen window-BOT COMPLETE -Nail exterior wall sheathing corner at kitchen sink & bed #1 near window & dining ='throughout-DINING NOT DONE, KITCHEN/BED ONE NAILS NOT IN FRAMING,GARAGE INCOMPLETE, ETC.-SEE PLANS FOR ALL BRACED WALL LOCATIONS AND COMPLETE NAILING PATTERN
All Rough Inspection - Residential Failed 9/21/2021 9/21/2021 09/21/2021
Miscellaneous Correction
Corrective Action Required
09/16/2021
-Nail exterior wall sheathing corner at kitchen sink & bed #1 near window & dining **Please nail exterior wall sheathing to sill plates throughout w/ 8d@6” oc **OK TO ROCK
All Rough Inspection - Residential Passed 9/23/2021 9/23/2021 09/23/2021
Miscellaneous Correction
Resolved
09/23/2021
-Nail exterior wall sheathing corner at kitchen sink & bed #1 near window & dining **Please nail exterior wall sheathing to sill plates throughout w/ 8d@6” oc **OK TO ROCK
Erosion Control Inspection Residential Failed 10/7/2021 10/07/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/16/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. MAINTAIN SILT FENCE CLEAN GRAVEL FROM STREET
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/16/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN GUTTER BUDDY AT CURB INLET & REMOVE SEDIMENT BUILD UP -
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/16/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - MAINTAIN SILT FENCE - - REMOVE TRASH & SEDIMENT BUILD UP AT CURB INLET -
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
10/07/2021
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Driveway Inspection Partial 10/15/2021 10/15/2021 10/14/2021
Misc
Informational
10/14/2021
10-14-21 AN forms are in place and aggregate is present and compacted . Informed contractor that some spots were not deep enough for the 6” of concrete.
Driveway Inspection Passed 10/22/2021 10/22/2021 10/19/2021
Misc
Informational
10/14/2021
10-14-21 AN forms are in place and aggregate is present and compacted . Informed contractor that some spots were not deep enough for the 6” of concrete.
Misc
Informational
10/19/2021
Driveway looks good and has expansion joints at curb and right of way. No sidewalk
Occupancy Inspection - Codes Residential Failed 1/12/2022 1/12/2022 01/12/2022
Misc
Resolved
01/12/2022
Misc
Corrective Action Required
01/12/2022
- as graded plot plan - Address grade in back - Spark ring required at floor outlet near stairs - Provide code complaint Hand rail in garage - Sump discharge 27” above grade - Final grading and sod - Submit back flow certification - Pay all fees - Provide splash blocks
Occupancy Inspection - Codes Residential Temporary C of O 1/18/2022 1/18/2022 01/18/2022
Misc
Corrective Action Required
01/12/2022
- as graded plot plan - Address grade in back - Sump discharge 27” above grade - Final grading and sod - Submit back flow certification - Provide splash blocks
Occupancy Inspection - Codes Residential Temporary C of O 3/18/2022 03/18/2022
Misc
Corrective Action Required
01/18/2022
- as graded plot plan - Address grade in back - Sump discharge 27” above grade - Final grading and sod - Provide splash blocks : TCO EXPIRES 4/15/22 :
Plot Plan Inspection Passed 4/14/2022 04/14/2022
Occupancy Inspection - Codes Residential Full C of O 4/15/2022 4/14/2022 04/14/2022
Misc
Resolved
04/14/2022
Documents & Images
Date Uploaded File Type Document Name
02/12/2021 Application Form W1 #42 - Permit App
02/12/2021 42 WOODSIDE RIDGE ROOF LAYOUT
02/12/2021 W1 #42 - Florence - Mediterranean - Sheets- signed
02/12/2021 LOT 42 FINAL
02/12/2021 2630568 RF SEALS 02052021
02/16/2021 Approved Plans APPROVED PLANS
02/16/2021 Approved Plans APPROVED TRUSS DRAWINGS
02/16/2021 Approved Plans APPROVED TRUSS LAYOUT
02/18/2021 Receipt Receipt for transaction:2021-000779
02/18/2021 Letter DS Building Permit
03/01/2021 Scope of Work Statement - W1 #42
03/01/2021 W1 #42 - Revised Florence - Mediterranean - Sheets- signed
03/01/2021 Approved Plans APPROVED PLANS
04/12/2021 Letter INSPECTION SUMMARY
04/23/2021 W1-42 Woodside Ridge Footing Inspection
04/23/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
09/02/2021 Letter INSPECTION SUMMARY
09/09/2021 Letter INSPECTION SUMMARY
09/09/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
09/21/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
10/19/2021 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/17/2022 Receipt Receipt for transaction:2022-000284
01/18/2022 Letter Codes Temporary Certificate of Occupancy
03/18/2022 Letter Codes Temporary Certificate of Occupancy
04/13/2022 Plot Plan APPROVED PLOT PLAN
04/14/2022 Letter INSPECTION SUMMARY
04/14/2022 Letter Field Certificate of Occupancy
04/14/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: