Summary
PRRES20210592
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
02/12/2021
02/22/2021
08/15/2021
06/13/2022
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
SCOTT@NEWMARKHONESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/24/2021 02/22/2021
Kim Brennan
Basement egress
Corrective Action Required
02/22/2021

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
City infrustructure
Corrective Action Required
02/22/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. Please show manhole located in the rear of the lot
Residential Plan Review Approved 02/24/2021 02/22/2021
Kim Brennan
12 Detail required separation between garage and living area including door
Corrective Action Required
02/22/2021

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) Does not specify self-closing
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
02/22/2021

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Plot Plan Review Rejected 02/17/2021 02/16/2021
Kim Brennan
Basement egress
Corrective Action Required
02/16/2021

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
City infrustructure
Corrective Action Required
02/16/2021

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. Please show manhole located in the rear of the lot
Residential Plan Review Rejected 02/17/2021 02/16/2021
Kim Brennan
12 Detail required separation between garage and living area including door
Corrective Action Required
02/12/2021

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) Does not specify self-closing
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
02/16/2021

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,249.22 $1,249.22 Paid 02/22/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/22/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/22/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 02/22/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 02/22/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 02/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/07/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 3/1/2021 (8:30) 3/1/2021 03/01/2021
Misc
Informational
03/01/2021
- NO PLANS ON SITE -
Footing Inspection - Residential Passed 3/1/2021 03/01/2021
Misc
Informational
03/01/2021
- UFER SE CORNER FOUNDATION WALL -
Underslab Plumbing Inspection - Residential Failed 4/13/2021 4/13/2021 04/13/2021
R506.2.5 Interior Underslab Drains
Corrective Action Required
04/13/2021
CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Misc
Corrective Action Required
04/13/2021
- COMPLETE UNDERSLAB PLUMBING - - COMPLETE UNDERSLAB INTERIOR DRAIN TILE -
Underslab Plumbing Inspection - Residential Passed 4/15/2021 4/15/2021 04/15/2021
R506.2.5 Interior Underslab Drains
Resolved
04/15/2021
Misc
Resolved
04/15/2021
All Rough Inspection - Residential Failed 6/23/2021 6/23/2021 06/23/2021
Misc
Corrective Action Required
06/23/2021
: PORTAL FRAME ONLY : NAIL OFF HOLD DOWNS FASTEN TOP PLATE TO HEADER WITH TWO ROWS 16D SINFERS 3" O.C. FASTEN SHEATHING TO HEADER, STUDS BLOCKING IN 3" GRID PATTERN
Piers/Caissons Inspection - Residential Failed 6/29/2021 (8:00) 6/29/2021 06/29/2021
Misc
Corrective Action Required
06/29/2021
Pier holes are completely full of water
Piers/Caissons Inspection - Residential Passed 7/7/2021 (8:00) 7/7/2021 07/07/2021
Misc
Resolved
07/07/2021
(2) 24 X 36
Sewer Service Inspection - R Passed 7/12/2021 7/12/2021 07/12/2021
Water Service Inspection - R Passed 7/26/2021 07/26/2021
Electrical Service Inspection Passed 8/12/2021 8/12/2021 08/12/2021
Gas Service Inspection - Residential Passed 8/12/2021 8/12/2021 08/12/2021
All Rough Inspection - Residential Failed 8/12/2021 8/12/2021 08/12/2021
Misc
Corrective Action Required
06/23/2021
: PORTAL FRAME ONLY : NAIL OFF HOLD DOWNS FASTEN TOP PLATE TO HEADER WITH TWO ROWS 16D SINKERS 3" O.C. FASTEN SHEATHING TO HEADER, STUDS BLOCKING IN 3" GRID PATTERN
Miscellaneous Correction
Corrective Action Required
08/12/2021
PFH portal frame garage panel splice shall be blocked and occur within 24" of mid height Per plan S4.0 detail 1 Provide anchor bolt within 12" of plate break garage Tighten anchor bolts throughout house Nail LIBs throughout Provide CS-PF braced wall method dining area per plan S4.1 detail 1 Fire block furr downs at fireplace Fire block at ceiling joist At master bed/bath/ closet Seal upward penetration master vanity Solid block & nail per code sheathing breaks owners closet & office Seal upward penetrations basements stairs Provide joist hanger & nail dbl hanger above basement tub Seal upward penetrations bed #2 closet Seal upward penetration DWV bed #2 Provide vertical fire blocking every 10' basement furr out Seal penetrations bed #3 /bath Vent all bath exhaust to daylight Provide anchor bolt end of plate patio door Nail exterior wall sheathing per code
All Rough Inspection - Residential Not Ready 8/26/2021 8/26/2021 08/26/2021
Misc
Corrective Action Required
08/12/2021
: PORTAL FRAME ONLY : NAIL OFF HOLD DOWNS FASTEN TOP PLATE TO HEADER WITH TWO ROWS 16D SINKERS 3" O.C. FASTEN SHEATHING TO HEADER, STUDS BLOCKING IN 3" GRID PATTERN
Miscellaneous Correction
Corrective Action Required
08/12/2021
PFH portal frame garage panel splice shall be blocked and occur within 24" of mid height Per plan S4.0 detail 1 Tighten anchor bolts throughout house Provide CS-PF braced wall method dining area per plan S4.1 detail 1 Fire block at ceiling joist At master bed/bath/ closet Seal upward penetration master vanity Solid block & nail per code sheathing breaks owners closet & office Provide vertical fire blocking every 10' basement furr out Seal penetrations bed #3 /bath Provide anchor bolt end of plate patio door Nail exterior wall sheathing per code : House has been insulated unable to verify work is complete :
All Rough Inspection - Residential Passed 8/27/2021 8/27/2021 08/27/2021
Misc
Resolved
08/27/2021
: PORTAL FRAME ONLY : OK TO COVER
Miscellaneous Correction
Resolved
08/27/2021
Driveway Inspection Partial 9/23/2021 9/23/2021 09/23/2021
Misc
Informational
09/23/2021
Forms are in places and aggregate is present and compacted. Had worker adjust the form to reach the 1.5% slope. Ready to concrete
Sidewalk Inspection Partial 9/23/2021 9/23/2021 09/23/2021
Misc
Informational
09/23/2021
Forms are in places and aggregate is present and compacted. Had worker adjust the form to reach the 1.5% slope. Ready to concrete
Driveway Inspection Passed 10/1/2021 10/1/2021 10/01/2021
Misc
Informational
09/23/2021
Forms are in places and aggregate is present and compacted. Had worker adjust the form to reach the 1.5% slope. Ready to concrete
Misc
Informational
10/01/2021
Driveway looks good with expansion joints at curb and right of way. Also meets all ADA specs
Sidewalk Inspection Passed 10/1/2021 10/1/2021 10/01/2021
Misc
Informational
09/23/2021
Forms are in places and aggregate is present and compacted. Had worker adjust the form to reach the 1.5% slope. Ready to concrete
Misc
Informational
10/01/2021
Sidewalk looks good and meets all ADA specs
Occupancy Inspection - Codes Residential Failed 12/8/2021 12/8/2021 12/08/2021
Miscellaneous Correction
Corrective Action Required
12/08/2021
Provide sod & splash blocks Seal top exterior light fixtures Provide gutters & downspouts Land conductors in a box or listed fixture right of cooktop Install ceiling fan or cover plate NW bedroom Complete backsplash & cover plates wet bar basement Seal top AC disconnect Land sewer tracer wire in a box at grade
Occupancy Inspection - Codes Residential Temporary C of O 12/16/2021 12/16/2021 12/16/2021
Miscellaneous Correction
Corrective Action Required
12/08/2021
Provide sod & splash blocks Seal top exterior light fixtures Provide gutters & downspouts OBTAIN LAWN IRRIGATION PERMIT SUBMIT BACK-FLOW CERTIFICATION : TCO EXPIRES 01/17/2022 :
Plot Plan Inspection Passed 1/21/2022 01/21/2022
Occupancy Inspection - Codes Residential Temporary C of O 1/21/2022 01/21/2022
Miscellaneous Correction
Corrective Action Required
12/16/2021
OBTAIN LAWN IRRIGATION PERMIT SUBMIT BACK-FLOW CERTIFICATION
Occupancy Inspection - Codes Residential Full C of O 6/13/2022 6/13/2022 06/13/2022
Miscellaneous Correction
Resolved
06/13/2022
Documents & Images
Date Uploaded File Type Document Name
02/12/2021 Application Form Permit Application and License Tax Form
02/16/2021 Letter Codes Residential Plan Review
02/22/2021 Approved Plans Approved Drawings
02/22/2021 Plot Plan Approved Plot Plan
02/22/2021 Receipt Receipt for transaction:2021-000813
02/22/2021 Letter DS Building Permit
03/01/2021 Letter INSPECTION SUMMARY
03/01/2021 Letter INSPECTION SUMMARY
04/13/2021 Letter INSPECTION SUMMARY
04/13/2021 Letter INSPECTION SUMMARY
04/15/2021 Letter INSPECTION SUMMARY
06/23/2021 Letter INSPECTION SUMMARY
06/29/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
12/07/2021 Receipt Receipt for transaction:2021-009166
12/08/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter Codes Temporary Certificate of Occupancy
01/21/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter Codes Temporary Certificate of Occupancy
06/13/2022 Letter Field Certificate of Occupancy
06/13/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home