Permit Application Status

PRRES20210350


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210350
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ENGINEERED ROOF SYSTEM - covered patio
01/26/2021
01/28/2021
11/09/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/28/2021 01/26/2021
Brandon Kalwei
Residential Plan Review Approved 01/28/2021 01/26/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,408.69 $1,408.69 Paid 01/28/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 01/28/2021
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 01/28/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/28/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/28/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/28/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/28/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/20/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $100.00 $100.00 Paid 10/20/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/10/2021 (10:30) 3/10/2021 03/10/2021
Underslab Plumbing Inspection - Residential Passed 4/14/2021 4/14/2021 04/14/2021
All Rough Inspection - Residential Failed 5/27/2021 5/27/2021 05/27/2021
Misc
Corrective Action Required
05/27/2021
**APRROVED TRUSS PLANS/DRAWINGS REQ ON SITE IF BEING INSPECTED WITH GARAGE PORTAL** 5/27/21 GARAGE PORTAL INSPECTION -HEADER TO JACK STUD STRAPS REQUIRED, SEE TABLE R602.10.6.4 -FASTEN TOP PLATE TO HEADER WITH TWO ROWS 16D NAILS AT 3" O.C.
Piers/Caissons Inspection - Residential Passed 6/1/2021 (8:30) 6/1/2021 06/01/2021
All Rough Inspection - Residential Not Ready 7/7/2021 7/7/2021 07/07/2021
Misc
Corrective Action Required
05/27/2021
**NO CITY APPROVED PLANS ON SITE AT TIME OF INSPECTION**
All Rough Inspection - Residential Failed 7/8/2021 7/8/2021 07/08/2021
Misc
Corrective Action Required
07/07/2021
-Fireblock box outs for DWV in garage -Solid block between joists in garage above beam- lateral restraint -Fireblock all tub and shower traps -Add stud shoe to over notched stud for pex at bathroom garage wall -Fireblock around DWV and HVAC at fridge dbl wall kitchen -Fireblock chases at great room windows -Fireblock vertical to horizontal at great room window chases -Connect gas line at fireplace -Dbl joist hanger above kitchen breakfast lvl connection -Fireblock deadspace dining room front windows -Seal all through floor and bottom plate penetrations -Truss hold downs at front porch and covered deck along breakfast wall -All truss hangers per plans -All truss bracing per plans -(2) 1 3/4” x 11 1/4” lvl header corner to corner with CS-PF design including nail pattern per plans at great room windows -Insulate 1st and then solid block at cantilevers -LIB bracing all locations per plans - see garage, 2nd floor bed #2 closet -(2) 1 3/4” x 9 1/4” lvl at dining room above cantilever garage per plans -Solid block at panel splices exterior braced north wall at foyer/stairs, nail exterior sheathing per wall design in plans -Shim 2X6 studs for bearing of front covered porch beam at stair wall, studs cut short of beam -strap 2x6 to 2x4 top plates at top 2nd floor stairs -12” oc nailing at all abutting and intersecting braced wall corners -Protection plate at DWV bottom plate master water closet -(4) 2x4 or 2x6 stud packs at all girder truss bearing ends per plans -Fireblock all tub and shower traps
Electrical Service Inspection Passed 7/8/2021 7/8/2021 07/08/2021
All Rough Inspection - Residential Failed 7/21/2021 7/21/2021 07/21/2021
Misc
Corrective Action Required
07/08/2021
-Fireblock chases at great room windows see right side above HVAV and DWV -Protection required of flex gas line at fireplace entrance also secure gas line at fireplace -land electrical to box hanging from ceiling at dining room windows and foyer -All truss hangers per plans-see garage -CS-PF design including nail pattern per plans at great room windows -strap 2x6 to 2x4 top plates at top 2nd floor stairs -see above foyer side as well
All Rough Inspection - Residential Passed 7/26/2021 7/26/2021 07/26/2021
Misc
Resolved
07/26/2021
Sewer Service Inspection - R Passed 8/19/2021 (10:30) 8/19/2021 08/19/2021
Water Service Inspection - R Passed 8/20/2021 (9:00) 8/20/2021 08/20/2021
Erosion Control Inspection Residential Failed 8/20/2021 8/20/2021 08/20/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/20/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Gas Service Inspection - Residential Failed 9/9/2021 9/9/2021 09/09/2021
Misc
Corrective Action Required
09/09/2021
GAS PRESSURE AT 5 PSI, MUST MAINTAIN 10 PSI FOR TEST
Gas Service Inspection - Residential Passed 9/10/2021 9/10/2021 09/10/2021
Misc
Resolved
09/10/2021
Sidewalk Inspection Passed 9/10/2021 9/10/2021 09/10/2021
Misc
Informational
09/10/2021
On Thursday September 10, 2021 I performed a sidewalk inspection and pass the subgrade to pour concrete
Driveway Inspection Passed 9/10/2021 9/10/2021 09/10/2021
Misc
Informational
09/10/2021
On Friday September 10, 2021 I performed a driveway inspection and pass the subgrade to pour concrete
Erosion Control Inspection Residential Passed 10/20/2021 10/20/2021
Misc
Resolved
10/20/2021
Plot Plan Inspection Passed 10/20/2021 10/20/2021
Occupancy Inspection - Codes Residential Failed 10/20/2021 10/20/2021 10/20/2021
Misc
Corrective Action Required
10/20/2021
-guard rail required at front stoop more than 30” from grade -obtain lawn irrigation permit -pay all fees before next inspection. -finish electrical above fireplace and add spark ring -security screws at back door two for each hinge and strike plate. -self closing door at garage -open electrical (garage ceiling) -add support for handrail at basement -complete front exterior lighting
Occupancy Inspection - Codes Residential Full C of O 11/9/2021 11/9/2021 11/09/2021
Misc
Resolved
11/09/2021
Documents & Images
Date Uploaded File Type Document Name
01/26/2021 Application Form APPLICATION
01/26/2021 RR #65 - TRUSS LAYOUT
01/26/2021 LOT 65 FINAL
01/26/2021 210212
01/26/2021 RR #65 - Charleston - Mediterranean - Sheets- signed
01/26/2021 Approved Plans APPROVED PLANS
01/26/2021 Approved Plans APPROVED TRUSS DRAWINGS
01/26/2021 Approved Plans APPROVED TRUSS LAYOUT
01/26/2021 Plot Plan APPROVED PLOT PLAN
01/28/2021 Receipt Receipt for transaction:2021-000444
01/28/2021 Letter DS Building Permit
03/10/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter INSPECTION SUMMARY
05/27/2021 Letter INSPECTION SUMMARY
06/01/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/20/2021 RR65 great room LVL engineer letter
07/21/2021 Letter INSPECTION SUMMARY
07/26/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
10/20/2021 Letter INSPECTION SUMMARY
10/20/2021 Letter INSPECTION SUMMARY
10/20/2021 Letter INSPECTION SUMMARY
10/20/2021 Receipt Receipt for transaction:2021-008124
10/25/2021 RR65 sprinkler permit
11/09/2021 Letter Field Certificate of Occupancy
11/09/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: