Permit Application Status

PRRES20210252


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210252
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
01/19/2021
01/29/2021
07/20/2021
12/09/2022
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
TRUMARKHOMES.MARK@GMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/27/2021 01/25/2021
Kim Brennan
Residential Plan Review Approved 01/27/2021 01/25/2021
Kim Brennan
03 Two (2) plot plans
Corrective Action Required
01/25/2021

No plot plan uploaded
07 Identify emergency escape openings from bedrooms
Corrective Action Required
01/25/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) Not shown in office/bedroom 2.
Plot Plan Review Approved 01/21/2021 01/22/2021
Kim Brennan
Basement opening elevations
Corrective Action Required
01/21/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. Does not reflect the MDP
Basement elevation
Corrective Action Required
01/21/2021

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.)
As-graded plot plan
Corrective Action Required
01/21/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Basement egress
Corrective Action Required
01/21/2021

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Plot Plan Review Rejected 01/25/2021 01/21/2021
Kim Brennan
Residential Plan Review Rejected 01/25/2021 01/21/2021
Kim Brennan
03 Two (2) plot plans
Corrective Action Required
01/21/2021

No plot plan uploaded
07 Identify emergency escape openings from bedrooms
Corrective Action Required
01/21/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) Not shown in office/bedroom 2.
Residential Plan Review Rejected 01/21/2021 01/20/2021
Kim Brennan
03 Two (2) plot plans
Corrective Action Required
01/19/2021

No plot plan uploaded
07 Identify emergency escape openings from bedrooms
Corrective Action Required
01/19/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) Not shown in office/bedroom 2.
Planning Review (RES) Approved 01/22/2021 01/20/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,221.68 $1,221.68 Paid 01/29/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/29/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/29/2021
8331507-Sewer Connection Fee $540.00 $540.00 Paid 01/29/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/29/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/29/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/27/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Partial 3/8/2021 (1:00) 3/8/2021 03/08/2021
Misc
Corrective Action Required
03/08/2021
- SUMBIT ENGINEERS SOIL REPORT & REPOT ON 8" LIFT COMPACTION ON AB-3 -
Underslab Plumbing Inspection - Residential Passed 3/30/2021 3/30/2021 03/30/2021
Sewer Service Inspection - R Passed 4/1/2021 (9:30) 4/1/2021 04/01/2021
Water Service Inspection - R Passed 4/2/2021 (8:15) 4/2/2021 04/02/2021
Erosion Control Inspection Residential Failed 5/10/2021 05/10/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/10/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Piers/Caissons Inspection - Residential Failed 6/18/2021 6/18/2021 06/18/2021
Misc
Corrective Action Required
06/18/2021
PUMP WATER OUT OF DECK PIERS
Erosion Control Inspection Residential Failed 6/18/2021 06/18/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/10/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/18/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. : MAINTAIN SILT FENCE :
Piers/Caissons Inspection - Residential Passed 6/23/2021 06/23/2021
Misc
Resolved
06/23/2021
PUMP WATER OUT OF DECK PIERS (2) 18 x 36
Rough Framing Inspection - Residential Failed 7/12/2021 7/12/2021 07/12/2021
Misc
Corrective Action Required
07/12/2021
eyebrow and tyvek accross the front unable to see nail pattern
Gas Service Inspection - Residential Passed 8/12/2021 8/12/2021 08/12/2021
Electrical Service Inspection Failed 8/12/2021 8/12/2021 08/12/2021
Miscellaneous Correction
Corrective Action Required
08/12/2021
PROVIDE METER CAN W/ DISCONNECT
All Rough Inspection - Residential Failed 8/12/2021 8/12/2021 08/12/2021
Miscellaneous Correction
Corrective Action Required
08/12/2021
Address spliced hip & valley above master closet Provide CS-PF braced wall method at SGD deck Vent bath exhaust to daylight Seal upward penetration dining/great room Seal upward penetrations DWV butlers pante Provide splitter card doorbell chime Provide 1/2 anchor bolts at stair landing & where required by code Seal vertical to horizontal fire blocking at top plate furr out basement Provide vertical fire blocking every 10' basement furr out Provide solid security blocking patio door Insulate & block cantilever at fireplace Seal upward penetrations bath near patio door Solid block sheathing breaks SW corner basement Drop ceiling bed #4 closet at beam Seal DWV bed #3 behind tub Provide mid point support DWV 2" & smaller bed 3 behind tub Nail exterior wall sheathing per code
Electrical Service Inspection Not Ready 8/18/2021 8/18/2021 08/18/2021
Miscellaneous Correction
Corrective Action Required
08/12/2021
PROVIDE METER CAN W/ DISCONNECT
All Rough Inspection - Residential Failed 8/18/2021 8/18/2021 08/18/2021
Miscellaneous Correction
Corrective Action Required
08/12/2021
Address spliced hip & valley above master closet Provide CS-PF braced wall method at SGD deck Seal upward penetrations DWV butlers panty (no) Seal vertical to horizontal fire blocking at top plate furr out basement (!not done) Provide vertical fire blocking every 10' basement furr out ( seal @ bed # 3 ) Drop ceiling bed #4 closet at beam ( seal gap at soffit) Nail exterior wall sheathing per code
All Rough Inspection - Residential Failed 8/19/2021 8/19/2021 08/19/2021
Miscellaneous Correction
Corrective Action Required
08/18/2021
Address spliced hip & valley rafters
Sidewalk Inspection Partial 9/7/2021 9/7/2021 09/07/2021
Misc
Informational
09/07/2021
Forms were placed and aggregate was present and compacted. Need to clean the roadway before pouring. RP 9-7-21
Driveway Inspection Partial 9/7/2021 9/7/2021 09/07/2021
Misc
Informational
09/07/2021
Forms were placed and aggregate was present and compacted. Need to clean the roadway before pouring. RP 9-7-21
Driveway Inspection Passed 9/10/2021 9/10/2021 09/10/2021
Misc
Informational
09/07/2021
Forms were placed and aggregate was present and compacted. Need to clean the roadway before pouring. RP 9-7-21
Misc
Informational
09/10/2021
Finished driveway meets LS and ADA specs. RP 9-10-21
Sidewalk Inspection Passed 9/10/2021 9/10/2021 09/10/2021
Misc
Informational
09/07/2021
Forms were placed and aggregate was present and compacted. Need to clean the roadway before pouring. RP 9-7-21
Misc
Informational
09/10/2021
Finished sidewalk meets LS and ADA specs. RP 9-10-21
Electrical Service Inspection Passed 10/28/2021 10/28/2021 10/28/2021
Miscellaneous Correction
Resolved
10/28/2021
All Rough Inspection - Residential Passed 1/21/2022 01/21/2022
Miscellaneous Correction
Resolved
01/21/2022
Footing Inspection - Residential Failed 01/21/2022
Misc
Corrective Action Required
03/08/2021
- SUMBIT ENGINEERS SOIL REPORT & REPORT ON 8" LIFT COMPACTION ON AB-3 -
Occupancy Inspection - Codes Residential Failed 1/21/2022 1/21/2022 01/21/2022
Misc
Corrective Action Required
01/21/2022
- SUMBIT ENGINEERS SOIL REPORT & REPORT ON 8" LIFT COMPACTION ON AB-3 PER FOOTING INSPECTION
Misc
Corrective Action Required
01/21/2022
1-21-22 HOUSE NOT READY FOR OCCUPANCY INSPECTION, CORRECT THESE ITEMS BEFORE RE SCHEDULING -PROVIDE EROSION CONTROL AT PERIMETER AND CLEAN DEBRIS FROM STREET - SUMBIT ENGINEERS SOIL REPORT & REPORT ON 8" LIFT COMPACTION ON AB-3 PER FOOTING INSPECTION -PROVIDE SECURITY LIGHTING AT FRONT PORCH -COMPLETE ALL TRADES INSIDE
Erosion Control Inspection Residential Failed 01/21/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
01/21/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/18/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. : MAINTAIN SILT FENCE, CLEAN DEBRIS FROM SIDEWALK AND STREET
Footing Inspection - Residential Passed 1/24/2022 01/24/2022
Misc
Resolved
01/24/2022
- 3rd PARTY ENGINEERS SOIL REPORT & REPORT ON 8" LIFT COMPACTION ON AB-3 BY RES -
Occupancy Inspection - Codes Residential Temporary C of O 1/26/2022 1/26/2022 01/26/2022
Misc
Resolved
01/26/2022
- SUMBIT ENGINEERS SOIL REPORT & REPORT ON 8" LIFT COMPACTION ON AB-3 PER FOOTING INSPECTION
Misc
Resolved
01/26/2022
1-21-22 HOUSE NOT READY FOR OCCUPANCY INSPECTION, CORRECT THESE ITEMS BEFORE RE SCHEDULING -PROVIDE EROSION CONTROL AT PERIMETER AND CLEAN DEBRIS FROM STREET - SUMBIT ENGINEERS SOIL REPORT & REPORT ON 8" LIFT COMPACTION ON AB-3 PER FOOTING INSPECTION -PROVIDE SECURITY LIGHTING AT FRONT PORCH -COMPLETE ALL TRADES INSIDE
Misc
Corrective Action Required
01/26/2022
-final grade and sod -splash blocks and sump pump discharge to be 36” from foundation -check water meter at time of final grade and sod -2 1/2” through bolts at all post to beam connections
Rough Framing Inspection - Residential Passed 3/18/2022 03/18/2022
Misc
Corrective Action Required
07/12/2021
eyebrow and tyvek accross the front unable to see nail pattern
Occupancy Inspection - Codes Residential Temporary C of O 3/18/2022 03/18/2022
Misc
Corrective Action Required
01/26/2022
-final grade and sod -splash blocks and sump pump discharge to be 36” from foundation -check water meter at time of final grade and sod -2 1/2” through bolts at all post to beam connections - SUBMIT AS GRADED PLOT PLAN - : SOD STILL NOT COMPLETE EXTEND TCO UNTIL 4/15/22 : Michael Harkins 03/18/2022 11:14 AM
Erosion Control Inspection Residential Passed 06/29/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/29/2022
Plot Plan Inspection Passed 6/29/2022 06/29/2022
Occupancy Inspection - Codes Residential Failed 7/22/2022 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
Misc
Corrective Action Required
07/22/2022
- PAY FEE FOR IRRIGATION PERMIT
Occupancy Inspection - Codes Residential Full C of O 12/09/2022
Misc
Resolved
12/09/2022
- PAY FEE FOR IRRIGATION PERMIT
Documents & Images
Date Uploaded File Type Document Name
01/19/2021 Application Form Application and license tax form
01/20/2021 Letter Codes Residential Plan Review
01/21/2021 Letter Codes Residential Plan Review
01/22/2021 Plot Plan Approved Plot Plan
01/25/2021 Approved Plans Approved Drawings
01/29/2021 Receipt Receipt for transaction:2021-000477
01/29/2021 Letter DS Building Permit
03/08/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
04/02/2021 Letter INSPECTION SUMMARY
05/10/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
06/23/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/18/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
09/07/2021 Letter INSPECTION SUMMARY
09/07/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
10/28/2021 Letter INSPECTION SUMMARY
12/26/2021 trumark homes backflow test
12/27/2021 Receipt Receipt for transaction:2021-009476
01/21/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
01/23/2022 98 Woodside Ridge AB3 Inspection (1)
01/23/2022 98 Woodside Ridge-Subgrade (1)
01/24/2022 Letter INSPECTION SUMMARY
01/26/2022 Letter Codes Temporary Certificate of Occupancy
03/18/2022 Letter INSPECTION SUMMARY
03/18/2022 Letter Codes Temporary Certificate of Occupancy
06/28/2022 Plot Plan Approved As Graded Plot Plan
06/29/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
12/09/2022 Letter Codes Final Certificate of Occupancy
12/09/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home