Permit Application Status

PRRES20210149


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210149
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSSES - COVERED DECK
01/11/2021
01/12/2021
09/30/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 01/13/2021 01/12/2021
Brandon Kalwei
Plot Plan Review Approved 01/13/2021 01/11/2021
Brandon Kalwei
Residential Plan Review Approved 01/13/2021 01/11/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,075.37 $1,075.37 Paid 01/12/2021
8331507-Sewer Connection Fee $450.00 $450.00 Paid 01/12/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/12/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/12/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/12/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/17/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Partial 2/4/2021 02/04/2021
Misc
Partial Correction
02/04/2021
- PROVIDE ADDRESS - - UPLOAD ENGINEERS SOIL REPORT TO PERMIT - - UFER FOUNDATION WALL REAR GARAGE -
Sewer Service Inspection - R Passed 3/3/2021 (9:15) 3/3/2021 03/03/2021
Water Service Inspection - R Passed 3/5/2021 (8:00) 3/5/2021 03/05/2021
Misc
Corrective Action Required
03/05/2021
- PROVIDE CORRECT ADDRESS -
Underslab Plumbing Inspection - Residential Failed 3/11/2021 3/11/2021 03/11/2021
R506.2.5 Interior Underslab Drains
Corrective Action Required
03/11/2021
- CONNECT INTERIOR DRAIN TILE TO SUMP - CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Erosion Control Inspection Residential Failed 3/12/2021 03/12/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/12/2021
- MAINTAIN SILT FENCE - DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 3/12/2021 3/12/2021 03/12/2021
R506.2.5 Interior Underslab Drains
Resolved
03/12/2021
- CONNECT INTERIOR DRAIN TILE TO SUMP - CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Piers/Caissons Inspection - Residential Passed 5/10/2021 (8:45) 5/10/2021 05/10/2021
Misc
Informational
05/10/2021
(2) 24 X 36 W/ (4) # 4 VERT BARS
Erosion Control Inspection Residential Failed 5/12/2021 05/12/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/12/2021
- MAINTAIN SILT FENCE - DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/12/2021
STREET CLEAN UP REQUIRED MAINTAIN SILT FENCE MAINTAIN GRAVEL FILTER
All Rough Inspection - Residential Failed 5/12/2021 5/12/2021 05/12/2021
Miscellaneous Correction
Corrective Action Required
05/12/2021
Upload Sub grade report for footing to permit Provide solid blocking at sheathing breaks & nail per code above front door & landing Fire block gaps in dead space entry closet Seal upward penetration (low volt ) near range Provide shield at box for microwave Fire block behind header at refrigerator range side Seal upward penetrations HVAC chase owners entry Header off cut ceiling joist pantry Provide solid security blocking deck door Seal DWV chase near patio door Provide stud shoes over bored studs at fireplace Seal upward & exterior penetrations garage front door side Tighten anchor bolts garage Tyvek tape nail penetrations at garage portal framing Provide SQ washer 5/8 anchor bolt PFH portal framing per plan Fasten top plate to header with two rows 16d sinkers at 3" OC per plan PFH portal framing Provide 1 roof vent covered deck per plan Expose TJC37 hangers covered deck Schedule Gas & Electric service inspections if ready
Gas Service Inspection - Residential Passed 5/20/2021 5/20/2021 05/20/2021
Electrical Service Inspection Passed 5/20/2021 5/20/2021 05/20/2021
All Rough Inspection - Residential Failed 5/20/2021 5/20/2021 05/20/2021
Miscellaneous Correction
Corrective Action Required
05/12/2021
Seal upward penetration (low volt ) near range (Seal at top plate to seal floor joist cavity) Fire block behind header at refrigerator range side Seal dead space entry closet at joist
All Rough Inspection - Residential Passed 5/24/2021 5/24/2021 05/24/2021
Miscellaneous Correction
Resolved
05/24/2021
Driveway Inspection Not Ready 6/4/2021 6/4/2021 06/04/2021
Misc
Corrective Action Required
06/04/2021
Approach was not ready. Call in a new inspection when it is ready. RP 6-4-21
Driveway Inspection Partial 6/4/2021 6/4/2021 06/04/2021
Misc
Corrective Action Required
06/04/2021
Approach was not ready. Call in a new inspection when it is ready. RP 6-4-21
Misc
Informational
06/04/2021
Forms were placed and aggregate was present and compacted. RP 6-4-21
Driveway Inspection Passed 6/11/2021 6/11/2021 06/11/2021
Misc
Corrective Action Required
06/04/2021
Approach was not ready. Call in a new inspection when it is ready. RP 6-4-21
Misc
Informational
06/04/2021
Forms were placed and aggregate was present and compacted. RP 6-4-21
Misc
Informational
06/11/2021
Finished driveway meets LS and ADA specs. RP 6-11-21
Sidewalk Inspection Partial 7/21/2021 7/21/2021 07/21/2021
Misc
Informational
07/21/2021
Forms were placed and aggregate was present and compacted. RP 7-21-21
Sidewalk Inspection Passed 7/30/2021 7/30/2021 07/30/2021
Misc
Informational
07/21/2021
Forms were placed and aggregate was present and compacted. RP 7-21-21
Misc
Informational
07/30/2021
Finished sidewalk meets LS and ADA specs. RP 7-30-21
Occupancy Inspection - Codes Residential Failed 8/11/2021 8/11/2021 08/11/2021
Miscellaneous Correction
Corrective Action Required
08/10/2021
PROVIDE ENGINEER'S SOIL REPORT FOOTING PARTIAL PASS PAY OUTSTANDING FEES PROVIDE FINAL GRADE PROVIDE SOD & DOWNSPOUTS LOWER WATER METER PIT LID TO GRADE, 14" TO 18" TOP OF METER TO LID SUMP PUMP SHALL DISCHARGE 36" FROM FOUNDATION PROVIDE TWO 3" SCREWS IN EACH EXTERIOR HINGE PROVIDE COVER PLATE RECETACLE IN FOYER PROVIDE BOX AT GRADE FOR SEWER TRACER WIRE PROVIDE GUARDRAIL FRONT PORCH OVER 30" TO GRADE SEAL EXTERIOR PENETRATIONS NEAR METER CAN, GAS METER SEAL TOP OF METER CAN, AC DISCONNECT, EXTERIOR LIGHT FIXTURES PROVIDE THROUGH BOLTS DECK BEAM TO POST AT STAIRS
Plot Plan Inspection Passed 9/14/2021 09/14/2021
Footing Inspection - Residential Passed 9/14/2021 09/14/2021
Misc
Resolved
09/14/2021
- UFER FOUNDATION WALL REAR GARAGE -
Occupancy Inspection - Codes Residential Temporary C of O 9/14/2021 9/14/2021 09/14/2021
Miscellaneous Correction
Corrective Action Required
08/11/2021
PAY OUTSTANDING FEES LOWER WATER METER PIT LID TO GRADE, 14" TO 18" TOP OF METER TO LID
Occupancy Inspection - Codes Residential Failed 9/20/2021 9/20/2021 09/20/2021
Miscellaneous Correction
Corrective Action Required
09/14/2021
LOWER WATER METER PIT LID TO GRADE, 14" TO 18" TOP OF METER TO LID
Occupancy Inspection - Codes Residential Full C of O 9/30/2021 9/30/2021 09/30/2021
Miscellaneous Correction
Resolved
09/30/2021
Documents & Images
Date Uploaded File Type Document Name
01/11/2021 Application Form APPLICATION
01/11/2021 Approved Plans APPROVED TRUSS LAYOUT
01/11/2021 Approved Plans APPROVED TRUSS DRAWINGS
01/11/2021 Plot Plan APPROVED PLOT PLAN
01/12/2021 Approved Plans APPROVED PLANS
01/12/2021 Receipt Receipt for transaction:2021-000161
01/12/2021 Letter DS Building Permit
02/04/2021 Letter INSPECTION SUMMARY
03/03/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/12/2021 Letter INSPECTION SUMMARY
03/12/2021 Letter INSPECTION SUMMARY
05/10/2021 Letter INSPECTION SUMMARY
05/10/2021 Letter INSPECTION SUMMARY
05/12/2021 Letter INSPECTION SUMMARY
05/12/2021 Letter INSPECTION SUMMARY
05/18/2021 W2 #45 - Palmer - Prairie - A3 GN1_0 S3_1 revision- signed (002)
05/20/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter INSPECTION SUMMARY
06/11/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
08/11/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter Codes Temporary Certificate of Occupancy
09/17/2021 Receipt Receipt for transaction:2021-007390
09/28/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter Field Certificate of Occupancy
10/06/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home