Permit Application Status

PRRES20210049


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210049
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - FLOOR JOISTS (DEFERRED) - COVERED DECK
01/05/2021
01/05/2021
07/04/2021
06/14/2022
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
PERMITTING@JFECONSTRUCTION.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/07/2021 01/05/2021
Brandon Kalwei
Residential Plan Review Approved 01/07/2021 01/05/2021
Brandon Kalwei
12 Detail required separation between garage and living area including door
Corrective Action Required
01/05/2021

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) details needed for garage door going into front foyer
Plot Plan Review Approved 01/07/2021 01/05/2021
Brandon Kalwei
Residential Plan Review Rejected 01/07/2021 01/05/2021
Brandon Kalwei
12 Detail required separation between garage and living area including door
Corrective Action Required
01/05/2021

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) details needed for garage door going into front foyer
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,770.44 $1,770.44 Paid 01/05/2021
8331507-Sewer Connection Fee $630.00 $630.00 Paid 01/05/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/05/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/05/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/05/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/05/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/14/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/3/2021 03/03/2021
Sewer Service Inspection - R Passed 3/24/2021 (11:30) 3/24/2021 03/24/2021
Water Service Inspection - R Partial 03/24/2021
Misc
Informational
03/24/2021
Partial water approval from structure to metallic connection customer side of meter
Water Service Inspection - R Passed 3/25/2021 (11:30) 3/25/2021 03/25/2021
Misc
Resolved
03/25/2021
Partial water approval from structure to metallic connection customer side of meter
Erosion Control Inspection Residential Failed 4/18/2022 04/09/2021
Misc
Corrective Action Required
04/09/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Underslab Plumbing Inspection - Residential Failed 4/9/2021 4/9/2021 04/09/2021
Misc
Corrective Action Required
04/09/2021
provide positive or neutral slope of interior underslab drain tile throughout
Underslab Electrical Inspection - Residential Passed 04/09/2021
Underslab Plumbing Inspection - Residential Passed 4/12/2021 4/12/2021 04/12/2021
Misc
Resolved
04/12/2021
provide positive or neutral slope of interior underslab drain tile throughout
Erosion Control Inspection Residential Failed 05/18/2021
Misc
Corrective Action Required
04/09/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
All Rough Inspection - Residential Failed 5/28/2021 5/28/2021 05/27/2021
Misc
Corrective Action Required
05/27/2021
Portal frame only -solid block panel splices and nail sheathing 3” oc to blocking
All Rough Inspection - Residential Partial 6/1/2021 6/1/2021 06/01/2021
Misc
Informational
06/01/2021
Portal frame approved
Gas Service Inspection - Residential Failed 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/22/2021
-No pressure
Electrical Service Inspection Passed 7/22/2021 7/22/2021 07/22/2021
All Rough Inspection - Residential Failed 7/22/2021 7/22/2021 07/22/2021
Misc
Resolved
07/22/2021
Portal frame approved
Misc
Corrective Action Required
07/22/2021
-Strap header and nail siding of dining CSPF walls per detail -Seal return air space at top plate of front bedroom -Loft windows larger than 9 sq. ft and located less than 18” above floor are required to be tempered glass **OK TO INSULATE
All Rough Inspection - Residential Failed 7/28/2021 7/28/2021 07/28/2021
Misc
Corrective Action Required
07/22/2021
-nail siding of dining CSPF walls per detail -Loft windows larger than 9 sq. ft and located less than 18” above floor are required to be tempered glass **OK TO INSULATE
Gas Service Inspection - Residential Not Ready 7/28/2021 7/28/2021 07/28/2021
Misc
Corrective Action Required
07/22/2021
-No pressure 7-28-21- still no pressure
All Rough Inspection - Residential Passed 7/30/2021 7/30/2021 07/30/2021
Misc
Resolved
07/30/2021
-nail siding of dining CSPF walls per detail -Loft windows larger than 9 sq. ft and located less than 18” above floor are required to be tempered glass **OK TO INSULATE
Gas Service Inspection - Residential Passed 7/30/2021 7/30/2021 07/30/2021
Misc
Resolved
07/30/2021
-No pressure 7-28-21- still no pressure
Driveway Inspection Partial 11/16/2021 11/16/2021
Misc
Informational
11/16/2021
Driveway is framed up and has aggregate in and compacted. 11/16 ES
Driveway Inspection Passed 11/24/2021 11/24/2021 11/24/2021
Misc
Informational
11/16/2021
Driveway is framed up and has aggregate in and compacted. 11/16 ES
Misc
Informational
11/24/2021
Driveway meets LS spec. 11/24 ES
Occupancy Inspection - Codes Residential Failed 1/10/2022 1/10/2022 01/10/2022
Miscellaneous Correction
Corrective Action Required
07/30/2021
-Loft windows larger than 9 sq. ft and located less than 18” above floor are required to be tempered glass
Misc
Corrective Action Required
01/10/2022
- Complete final grading and sod - Obtain splash blocks - lightning fixture with in 8’ on tub edge - Lock and secondary lock for sliding door to deck - 2@ 1/2” through bolts on each post to beam connections
Occupancy Inspection - Codes Residential Temporary C of O 1/13/2022 1/13/2022 01/13/2022
Miscellaneous Correction
Resolved
01/13/2022
Misc
Corrective Action Required
01/10/2022
- Complete final grading and sod
Piers/Caissons Inspection - Residential Passed 06/14/2022
Plot Plan Inspection Passed 06/14/2022
Erosion Control Inspection Residential Passed 6/14/2022 06/14/2022
Misc
Resolved
06/14/2022
Occupancy Inspection - Codes Residential Full C of O 6/14/2022 6/14/2022 06/14/2022
Misc
Resolved
06/14/2022
Documents & Images
Date Uploaded File Type Document Name
01/05/2021 Application Form APPLICATION
01/05/2021 Application Form excise tax
01/05/2021 Letter Codes Residential Plan Review
01/05/2021 Plot Plan APPROVED PLOT PLAN
01/05/2021 Approved Plans APPROVED PLANS
01/05/2021 Receipt Receipt for transaction:2021-000050
01/05/2021 Letter DS Building Permit
03/03/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/25/2021 Letter INSPECTION SUMMARY
04/09/2021 Letter INSPECTION SUMMARY
04/09/2021 Letter INSPECTION SUMMARY
04/09/2021 Letter INSPECTION SUMMARY
04/12/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/27/2021 Letter INSPECTION SUMMARY
06/01/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
11/16/2021 Letter INSPECTION SUMMARY
11/24/2021 Letter INSPECTION SUMMARY
01/10/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter Codes Temporary Certificate of Occupancy
06/02/2022 Letter Codes 140 Day Letter
06/14/2022 Receipt Receipt for transaction:2022-004632
06/14/2022 Letter Codes Final Certificate of Occupancy
06/14/2022 Letter Field Certificate of Occupancy
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home