Permit Application Status

PRRES20204976


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204976
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASMENT - COVERED DECK
12/30/2020
01/04/2021
10/07/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
PERMITTING@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/04/2021 12/30/2020
Brandon Kalwei
Residential Plan Review Approved 01/04/2021 12/30/2020
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $959.32 $959.32 Paid 01/04/2021
8331507-Sewer Connection Fee $360.00 $360.00 Paid 01/04/2021
Right of Way Permit Fee $80.00 $80.00 Paid 01/04/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/04/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 01/04/2021
Water Meter Fee $455.54 $455.54 Paid 01/04/2021
3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 08/11/2021
3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 08/11/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/25/2021 1/25/2021 01/25/2021
Underslab Plumbing Inspection - Residential Failed 3/22/2021 3/22/2021 03/22/2021
Misc
Corrective Action Required
03/22/2021
-SET SUMP PUMP INTERIOR DRAIN TILE
Underslab Plumbing Inspection - Residential Passed 3/23/2021 3/23/2021 03/23/2021
Misc
Resolved
03/23/2021
-SET SUMP PUMP INTERIOR DRAIN TILE
Electrical Service Inspection Failed 5/25/2021 5/25/2021 05/25/2021
Misc
Corrective Action Required
05/25/2021
-Color code GEC at service panel
All Rough Inspection - Residential Failed 5/25/2021 5/25/2021 05/25/2021
Misc
Corrective Action Required
05/25/2021
-Staple plans together in order -seal all top plate penetrations throughout -Jack tension straps at garage PFH, see table R602.10.6.4 -Garage PFH panel splices edges shall occur within middle 24” of wall mid height. One row 3” oc nailing required each edge of panel with blocking -Fireblock B vent chase at mud room -Security blocking at exterior doors -Fireblock dead space front bedroom closet -LIB bracing all locations per plans -Dining room window and basement windows exterior bracing method per plans: 15/32” osb with 24/0 span 8D nails at 6” edge 12” field. Install blocking at base, mid height and top of windows. Continuous sheathing over band joist with min lap 9 1/4”. At h sheathing with min 8D common nails at 3” oc at top and bottom of band/rim joist -Covered deck sliding door, master bed windows, basement sliding door exterior bracing design per plans CS-PF, strap, wood structural panel continuous over band joist with min lap 9 1/4”. Attach sheathing with 8D nails at 3” oc at top and bottom band joist -Min (4) 2x4 stud pack at all girder truss bearing ends per plans -Jack studs cut short at 1st floor windows, basement windows, replace or use approved shims where applicable -Complete gas line installation, no gas lines present at rough inspection -Fireblock vertical every 10’ between foundation/framing, seal all gaps/penetrations at fireblock material -Nail exterior sheathing per plans 6” edge 12” field -deck ledger attachment per code -proper dbl beam connection to house at deck -(2) 1/2” through bolts at each post/beam connection per code
Gas Service Inspection - Residential Passed 6/1/2021 6/1/2021 06/01/2021
All Rough Inspection - Residential Failed 6/1/2021 6/1/2021 06/01/2021
Misc
Corrective Action Required
05/25/2021
-seal all top plate penetrations throughout - see garage, basement -Fireblock B vent chase at mud room -LIB bracing all locations per plans -see bath#2 -seal gas line floor penetration at fireplace -Dining room window and basement windows exterior bracing method per plans: 15/32” osb with 24/0 span 8D nails at 6” edge 12” field. Install blocking at base, mid height and top of windows. Continuous sheathing over band joist with min lap 9 1/4”. At h sheathing with min 8D common nails at 3” oc at top and bottom of band/rim joist -basement sliding door exterior bracing design per plans CS-PF, strap, wood structural panel continuous over band joist with min lap 9 1/4”. Attach sheathing with 8D nails at 3” oc at top and bottom band joist -Jack studs cut short at basement bed windows, replace or use approved shims where applicable -deck ledger attachment per code -proper dbl beam connection to house at deck -(2) 1/2” through bolts at each post/beam connection per code
All Rough Inspection - Residential Failed 6/3/2021 6/3/2021 06/03/2021
Misc
Corrective Action Required
06/01/2021
-LIB bracing all locations per plans -see bath#2 -Dining room window and basement windows exterior bracing method per plans: 15/32” osb with 24/0 span 8D nails at 6” edge 12” field. Install blocking at base, mid height and top of windows. Continuous sheathing over band joist with min lap 9 1/4”. At h sheathing with min 8D common nails at 3” oc at top and bottom of band/rim joist -basement sliding door exterior bracing design per plans CS-PF, strap, wood structural panel continuous over band joist with min lap 9 1/4”. Attach sheathing with 8D nails at 3” oc at top and bottom band joist -Jack studs cut short at basement bed windows, replace or use approved shims where applicable -deck ledger attachment per code -proper dbl beam connection to house at deck -(2) 1/2” through bolts at each post/beam connection per code
Electrical Service Inspection Failed 6/3/2021 6/3/2021 06/03/2021
Misc
Corrective Action Required
05/25/2021
-Color code GEC at service panel
All Rough Inspection - Residential Passed 6/7/2021 6/7/2021 06/07/2021
Misc
Resolved
06/07/2021
Electrical Service Inspection Passed 6/9/2021 6/9/2021 06/09/2021
Misc
Resolved
06/09/2021
Sewer Service Inspection - R Passed 6/28/2021 (10:45) 6/28/2021 06/28/2021
Water Service Inspection - R Passed 6/29/2021 (11:30) 6/29/2021 06/29/2021
Driveway Inspection Partial 7/22/2021 7/22/2021 07/22/2021
Misc
Informational
07/22/2021
7/22/21 13:50 - Driveway has the correct depth of rock, correct depth for the concrete, and is carrying the correct % throughout the sidewalk.
Sidewalk Inspection Partial 7/22/2021 7/22/2021 07/22/2021
Misc
Informational
07/22/2021
7/22/21 13:56 - Sidewalk is the correct depth, correct depth of rock has been installed, 5ft off the back of the curb, and is carrying the correct % throughout.
Driveway Inspection Passed 7/28/2021 7/28/2021 07/28/2021
Misc
Informational
07/22/2021
7/22/21 13:50 - Driveway has the correct depth of rock, correct depth for the concrete, and is carrying the correct % throughout the sidewalk.
Misc
Informational
07/28/2021
7/28/21 14:40 - Driveway is carrying the correct % throughout, and has white cure on it.
Sidewalk Inspection Passed 7/28/2021 7/28/2021 07/28/2021
Misc
Informational
07/22/2021
7/22/21 13:56 - Sidewalk is the correct depth, correct depth of rock has been installed, 5ft off the back of the curb, and is carrying the correct % throughout.
Misc
Informational
07/28/2021
7/28/21 14:40 - Sidewalk is carrying the correct % throughout and has been white cured.
Occupancy Inspection - Codes Residential Failed 8/10/2021 8/10/2021 08/10/2021
Misc
Corrective Action Required
08/10/2021
-Resolve outstanding inspection fees before final c of o -Final grade and sod -splash blocks at downspouts and sump pump -complete stone/siding front of house -finished basement wet bar -install fixture or cover plate at ceiling box basement den -complete deck stairs at landing, 7 3/4” max rise -attic access required -Handrail required at garage stairs
Occupancy Inspection - Codes Residential Temporary C of O 8/18/2021 8/18/2021 08/18/2021
Misc
Corrective Action Required
08/10/2021
-sod -splash blocks at downspouts and sump pump -set sewer tracer to box and set to grade -obtain lawn irrigation system permit -set water meter lid to grade, maintain 14"-18" clearance from top of meter to top of lid **OK FOR TCO - TCO EXPIRES 9/1/21**
Occupancy Inspection - Codes Residential Failed 9/8/2021 9/8/2021 09/08/2021
Misc
Corrective Action Required
08/18/2021
-support sump pump discharge, heel and discharge line above grade -Uncover manhole MH21 as shown on plot plan at front of lot and raise to grade if necessary
Erosion Control Inspection Residential Passed 09/08/2021
Plot Plan Inspection Failed 09/08/2021
Misc
Corrective Action Required
09/08/2021
-Uncover manhole MH21 as shown on plot plan at front of lot and raise to grade if necessary
Occupancy Inspection - Codes Residential Full C of O 10/7/2021 10/7/2021 10/07/2021
Misc
Resolved
10/07/2021
Plot Plan Inspection Passed 10/7/2021 10/7/2021 10/07/2021
Misc
Resolved
10/07/2021
Documents & Images
Date Uploaded File Type Document Name
12/30/2020 Application Form APPLICATION
12/30/2020 Approved Plans APPROVED PLANS
12/30/2020 Approved Plans APPROVED TRUSS LAYOUT
12/30/2020 Approved Plans APPROVED TRUSS DRAWINGS
12/30/2020 Plot Plan APPROVED PLOT PLAN
01/04/2021 Receipt Receipt for transaction:2021-000007
01/04/2021 Letter DS Building Permit
01/21/2021 Lot 2 Hawthorn Ridge Footing Inspection
01/25/2021 Letter INSPECTION SUMMARY
02/02/2021 Lot 2 Hawthorn Ridge Wall Inspection
03/22/2021 Letter INSPECTION SUMMARY
03/23/2021 Letter INSPECTION SUMMARY
05/25/2021 Letter INSPECTION SUMMARY
05/25/2021 Letter INSPECTION SUMMARY
06/01/2021 Letter INSPECTION SUMMARY
06/01/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
06/07/2021 2 Hawthorne Ridge Braced wall panels letter
06/07/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/28/2021 Letter INSPECTION SUMMARY
06/29/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
07/28/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter INSPECTION SUMMARY
08/11/2021 Receipt Receipt for transaction:2021-006435
08/18/2021 Letter Codes Temporary Certificate of Occupancy
09/08/2021 Letter INSPECTION SUMMARY
09/08/2021 Letter INSPECTION SUMMARY
09/08/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter Field Certificate of Occupancy
10/07/2021 Letter Codes Final Certificate of Occupancy
10/07/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home