Summary
PRRES20204953
Building Permit - Residential
Certificate of Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
12/29/2020
12/30/2020
12/22/2023
Locations
Contacts
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
JPROBERTS23@HOTMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/04/2021 12/30/2020
Brandon Kalwei
Residential Plan Review Approved 01/04/2021 12/30/2020
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,047.21 $1,047.21 Paid 12/30/2020
$1,077.12
Right of Way Permit Fee $80.00 $80.00 Paid 12/30/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/29/2020
$1,077.12
New Longview Road and Bridge Escrow $1,077.12 $1,077.12 Paid 12/30/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 12/30/2020
Water Meter Fee $455.54 $455.54 Paid 12/30/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 12/30/2020
Not Ready Inspection Fee $50.00 $50.00 Paid 10/15/2021
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 02/04/2021
Misc
Corrective Action Required
02/04/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Miscellaneous Inspection Failed 02/04/2021
Misc
Corrective Action Required
02/04/2021
Post site address
Footing Inspection - Residential Failed 2/4/2021 02/04/2021
Misc
Corrective Action Required
02/04/2021
Provide third-party inspection report within 48 hours
Footing Inspection - Residential Passed 2/8/2021 02/08/2021
Misc
Resolved
02/08/2021
Provide third-party inspection report within 48 hours
Erosion Control Inspection Residential Passed 03/05/2021
Misc
Resolved
03/05/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Miscellaneous Inspection Passed 03/05/2021
Misc
Resolved
03/05/2021
Post site address
Underslab Plumbing Inspection - Residential Passed 3/5/2021 3/5/2021 03/05/2021
All Rough Inspection - Residential Partial 5/4/2021 5/4/2021 05/04/2021
Misc
Informational
05/04/2021
Portal frame approved Ok to cover underside of covered porch
Sewer Service Inspection - R Passed 5/26/2021 05/26/2021
Water Service Inspection - R Passed 5/28/2021 (11:15) 5/28/2021 05/28/2021
All Rough Inspection - Residential Not Ready 7/7/2021 7/7/2021 07/07/2021
Misc
Corrective Action Required
05/04/2021
Portal frame approved Ok to cover underside of covered porch
Misc
Corrective Action Required
07/07/2021
no erosion control , over grown vegetation. silt fence, gravel, strawl waddles over the curb. install approved silt fence and clean the street.
Electrical Service Inspection Passed 7/8/2021 07/08/2021
Gas Service Inspection - Residential Passed 7/8/2021 07/08/2021
All Rough Inspection - Residential Failed 7/8/2021 7/8/2021 07/08/2021
Misc
Resolved
07/08/2021
Portal frame approved Ok to cover underside of covered porch
Misc
Corrective Action Required
07/07/2021
Cut Joist rear basement at 3 inch DWV. - anchor bearing walls in basement around stairs. -Fire stop landing from stud wall both sides. Protect Romax at beam post first floor. - Provide engineers report on full burn of I-beam on 2 x 6 wall stairwell. -Seal gas line through floor at fireplace. - Solid block/ fire stop each side of heat chase heat chase in pantry, solid block not loose insulation. -Strap tall wall on east side of garage at top plate level @ garage separation wall. -Strap tall wall at top plate intersections at stairs over landing. - terminate Romex top of master bedroom ceiling at vault. - protection for Romex at master bedroom wall at double stud. - Vent master bath fan. -Strap top plates bedroom 3 south wall ,less than 24 inches lap. - Support Valley front bedroom west corner to LVL, LVL unsupported to double LVL ceiling header. -Fur out laundry drain in front closet second floor, install nail protection were required. -Provide fall in plumbing vent attic, needs to fall back to drain. -Install rafter ties in lower third of rafter span over front bedroom from LVL to front wall. -Revised plans or engineer vaulted ceiling in master bedroom. Provide details on rafter span with additional ceiling load. 2x6. Do not cover.
All Rough Inspection - Residential Failed 7/14/2021 7/14/2021 07/14/2021
Misc
Corrective Action Required
07/08/2021
- Provide engineers report on full burn of I-beam on 2 x 6 wall stairwell. -Strap tall wall on east side of garage at top plate level @ garage separation wall. -Strap tall wall at top plate intersections at stairs over landing. **strap walls at top plates left to right (side to side) not up and down. Corners where top plates to not over lap. use Simpson strap and connect top plates , strap at corner intersections. -Strap top plates bedroom 3 south wall ,less than 24 inches lap. -Fur out laundry drain in front closet second floor, install nail protection were required.* now fire stop top from attic. -Install rafter ties in lower third of rafter span over front bedroom from LVL to front wall. -Revised plans or engineer vaulted ceiling in master bedroom. Provide details on rafter span with additional ceiling load. 2x6. Do not cover.
All Rough Inspection - Residential Failed 7/15/2021 7/15/2021 07/15/2021
Misc
Corrective Action Required
07/14/2021
- Provide engineers report on full burn of I-beam on 2 x 6 wall stairwell. -Strap tall wall on east side of garage at top plate level @ garage separation wall. -Strap tall wall at top plate intersections at stairs over landing. **strap walls at top plates left to right (side to side) not up and down. Corners where top plates to not over lap. use Simpson strap and connect top plates , strap at corner intersections. -Strap top plates bedroom 3 south wall ,less than 24 inches lap. -Fur out laundry drain in front closet second floor, install nail protection were required.* now fire stop top from attic. -Install rafter ties in lower third of rafter span over front bedroom from LVL to front wall. -Revised plans or engineer vaulted ceiling in master bedroom. Provide details on rafter span with additional ceiling load. 2x6. Do not cover.
All Rough Inspection - Residential Failed 7/19/2021 7/19/2021 07/19/2021
Misc
Corrective Action Required
07/15/2021
-Strap top plates bedroom 3,less than 24 inches lap. -seal top plate penetration at 2nd floor laundry DWV, fireblock DWV chase at closet -Install rafter ties in lower third of rafter span over front bedroom from LVL to front wall.
All Rough Inspection - Residential Passed 7/20/2021 7/20/2021 07/20/2021
Misc
Resolved
07/20/2021
Sidewalk Inspection Passed 9/29/2021 9/29/2021 09/29/2021
Misc
Informational
09/29/2021
On Wednesday, 9-29-2021. I performed a sidewalk inspection that passed and is ready for concrete placement.
Occupancy Inspection - Codes Residential Failed 10/15/2021 10/15/2021 10/15/2021
Miscellaneous Correction
Corrective Action Required
10/15/2021
Pay outstanding fees Obtain lawn irrigation permit & Submit back-flow certification Plot plan shows manhole cover front at sidewalk Driveway inspection pending Provide final grade Provide sod, splash blocks Provide strike plate front door Seal top exterior light fixtures Seal top of meter can, ac disconnect Provide clamp at ax whip Provide non combustible surface at fireplace Provide secondary lock SGD Test button on smokes won't trip circuit breaker Provide self closing & self latching door garage to dwelling Sump shall discharge 36" from foundation Provide box extensions for receptacle & switch boxes recessed more than 1/4" behind kitchen countertop backsplash
Occupancy Inspection - Codes Residential Temporary C of O 10/22/2021 10/22/2021 10/22/2021
Miscellaneous Correction
Corrective Action Required
10/15/2021
Pay outstanding fees Driveway inspection pending Provide final grade Provide sod, splash blocks
Driveway Inspection Passed 12/22/2023
Misc
Informational
12/22/2023
12-22-23 Dustin A, DW is not connected to public street and is private.
Plot Plan Inspection Passed 12/22/2023 12/22/2023
Occupancy Inspection - Codes Residential Full C of O 12/22/2023 12/22/2023 12/22/2023
Miscellaneous Correction
Resolved
12/22/2023
Documents & Images
Date Uploaded File Type Document Name
12/30/2020 Application Form APPLICATION
12/30/2020 Plot Plan APPROVED PLOT PLAN
12/30/2020 Application Form excise tax
12/30/2020 Approved Plans APPROVED PLANS
12/30/2020 Receipt Receipt for transaction:2020-008272
12/30/2020 Letter DS Building Permit
02/04/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/08/2021 104 Pergola Park Subgrade
02/08/2021 Lot 104 Pergola Park Footing Inspection
02/08/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
05/04/2021 Letter INSPECTION SUMMARY
05/04/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
05/28/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/08/2021 Letter INSPECTION SUMMARY
07/14/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
07/18/2021 3217 SW Mary Rough-In Inspection
07/19/2021 Letter INSPECTION SUMMARY
09/29/2021 Letter INSPECTION SUMMARY
10/15/2021 Receipt Receipt for transaction:2021-008025
10/15/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter Codes Temporary Certificate of Occupancy
03/11/2022 Letter Codes 140 Day Letter
12/22/2023 Letter INSPECTION SUMMARY
12/22/2023 Letter INSPECTION SUMMARY
12/22/2023 Letter Field Certificate of Occupancy
12/22/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home