Summary
PRRES20204561
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
12/02/2020
12/15/2020
06/30/2022
06/21/2022
Locations
Contacts
GALE HOMES II INC, Address:400 SW LONGVIEW BLVD, Unit 109, Phone:(816) 761-9292  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
MC ELECTRICAL SERVICES INC, Address:1502 N VANSANT RD, Phone:(816) 392-3970  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
MFAULKNER@GALECOMMUNITIES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/17/2020 12/15/2020
Kim Brennan
Residential Plan Review Approved 12/17/2020 12/15/2020
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
12/15/2020

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) No egress location shown for Juliana's Suite
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
12/15/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) No smoke detector shown in owner's suite
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
12/15/2020

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
Misc
Corrective Action Required
12/15/2020

The address shows 2925 NW Audubon but should show 211 NW Carson Drive.
Plot Plan Review Approved 12/04/2020 12/15/2020
Kim Brennan
Basement elevation
Corrective Action Required
12/03/2020

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) The master drainage plan calls for a standard basement on this lot; not a walkout/walkup.
As-graded plot plan
Corrective Action Required
12/03/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Rejected 12/04/2020 12/02/2020
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
12/02/2020

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) No egress location shown for Juliana's Suite
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
12/02/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) No smoke detector shown in owner's suite
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
12/02/2020

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
Misc
Corrective Action Required
12/03/2020

The address shows 2925 NW Audubon but should show 211 NW Carson Drive.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,931.29 $1,931.29 Paid 12/15/2020
Right of Way Permit Fee $80.00 $80.00 Paid 12/15/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/15/2020
8331507-Sewer Connection Fee $810.00 $810.00 Paid 12/15/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 12/15/2020
Water Meter Fee $455.54 $455.54 Paid 12/15/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/5/2021 (10:30) 2/5/2021 02/05/2021
Sewer Service Inspection - R Passed 3/26/2021 (1:00) 3/26/2021 03/26/2021
Water Service Inspection - R Partial 3/26/2021 (1:00) 3/26/2021 03/26/2021
Misc
Informational
03/26/2021
Partial water approval from structure to metallic connection customer side of meter
Water Service Inspection - R Passed 3/29/2021 (11:15) 3/29/2021 03/29/2021
Misc
Resolved
03/29/2021
Partial water approval from structure to metallic connection customer side of meter
Underslab Plumbing Inspection - Residential Passed 3/30/2021 3/30/2021 03/30/2021
Gas Service Inspection - Residential Failed 10/13/2021 10/13/2021 10/13/2021
Misc
Corrective Action Required
10/13/2021
-Bond gas line before first CSST connection
Electrical Service Inspection Failed 10/13/2021 10/13/2021 10/13/2021
Misc
Corrective Action Required
10/13/2021
-Complete sub panel -Use rebar clamps listed for use with copper at Ufer -Remove bonding screws from panels
All Rough Inspection - Residential Failed 10/13/2021 10/13/2021 10/13/2021
Miscellaneous Correction
Corrective Action Required
10/13/2021
-Unable to inspect and approve covered PFH nailing pattern and braced wall patnels at front -Double bottom plate, studs not connected to plate at PFH, Nail top plate to header per code, straps not nailed etc. COMPLETE PFH per code both bays -Anchor bolts within 12” of plate break -Solid block and nail sheathing seams throughout -Strap top plates at exterior walls garage/ master not overlapping 24” -Address rafters landing on blocks -Bottom plate to be same size minimum of studs at garage/ bath -Connect bath exhaust fans -Seal plate penetrations at bath -Seal upward penetrations at elevator -Plate penetration at hallway/kitchen -Joist hangers guest suite -Plate penetrations top plate guest suit bath -Plate penetration at guest closet -Seal penetrations throughout -Protection plate at nm by sliding glass door -Protection plate at nm master shower -Complete fireplace gas piping -Address rafters not connected to joists at living room -Ledger connection and hangers at decks -(2) 1/2" through bolts at all post to beam connections -(4) 2x4 at beam in dining -Address walls not full height per plan -Bond metallic gas line before first connection of csst -Identify white current carrying conductors as current carrying conductors at both points of termination -Complete sub panel -Remove bonding screws at panels -FB soffit line at columns-FB beam webs in finished spaces -Protection plate at nm NE basement corner by window and under East window -FB soffit line at hallway/ guest bed, laundry Install missing windows -FB vertical 10’ oc in East bed -FB ceilling line at bath -Address top cord on I joist cut for step down -Use rebar clamps listed for use with copper at ufer
Gas Service Inspection - Residential Passed 11/2/2021 11/2/2021 11/02/2021
Misc
Resolved
11/02/2021
Electrical Service Inspection Passed 11/2/2021 11/2/2021 11/02/2021
Misc
Resolved
11/02/2021
All Rough Inspection - Residential Failed 11/2/2021 11/2/2021 11/02/2021
Miscellaneous Correction
Corrective Action Required
10/13/2021
-Solid block and nail sheathing /-Bottom plate to be same size minimum of studs at garage/ bath /-Connect bath exhaust fans -/Seal upward penetrations at elevator -(2) 1/2" through bolts at all post to beam connections Install missing windows
All Rough Inspection - Residential Passed 11/3/2021 11/3/2021 11/03/2021
Miscellaneous Correction
Resolved
11/03/2021
-Solid block and nail sheathing /-Bottom plate to be same size minimum of studs at garage/ bath /-Connect bath exhaust fans -/Seal upward penetrations at elevator -(2) 1/2" through bolts at all post to beam connections Install missing windows
Driveway Inspection Partial 11/15/2021 11/15/2021
Misc
Informational
11/15/2021
Driveway was framed up with aggregate in place and compacted. 11/15 ES
Sidewalk Inspection Partial 11/16/2021
Misc
Informational
11/16/2021
Sidewalk was framed up with aggregate in place and compacted. Left note for north end around storm box being right at or just out of tolerance.. 11/15 ES
Sidewalk Inspection Passed 11/24/2021 11/24/2021
Misc
Informational
11/24/2021
Sidewalk was framed up with aggregate in place and compacted. Left note for north end near storm box being slightly out of tolerance for ADA. 11/15 ES
Misc
Informational
11/24/2021
Misc
Informational
11/24/2021
Sidewalk meets LS and ADA spec. 11/24 ES
Driveway Inspection Passed 11/24/2021 11/24/2021 11/24/2021
Misc
Informational
11/15/2021
Driveway was framed up with aggregate in place and compacted. 11/15 ES
Misc
Informational
11/24/2021
Driveway meets LS and ADA spec. 11/24 ES
Erosion Control Inspection Residential Failed 6/1/2022 06/01/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/01/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Plot Plan Inspection Passed 6/15/2022 06/15/2022
Deck Final Inspection - Residential Failed 6/15/2022 06/15/2022
Miscellaneous Correction
Corrective Action Required
06/15/2022
- nail off joist hangers deck - support CSST gas line to code
Piers/Caissons Inspection - Residential Passed 6/15/2022 06/15/2022
Miscellaneous Correction
Informational
06/15/2022
Piers poured at time of footing, on plans.
Occupancy Inspection - Codes Residential Failed 6/15/2022 6/15/2022 06/15/2022
Miscellaneous Correction
Corrective Action Required
06/15/2022
- Label non gfci outlets - Provide security screws in door - Nail off deck joist hangers - Support CSST gas line under deck. - Provide handrail for stairs from basement to pool - guard rail required if level change over 30” by pool and steps ( I Have confirmed this)
Erosion Control Inspection Residential Passed 6/15/2022 06/15/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/15/2022
Deck Final Inspection - Residential Passed 06/21/2022
Miscellaneous Correction
Resolved
06/21/2022
Occupancy Inspection - Codes Residential Full C of O 6/21/2022 6/21/2022 06/21/2022
Miscellaneous Correction
Resolved
06/21/2022
Documents & Images
Date Uploaded File Type Document Name
12/02/2020 Application Form Permit Application
12/02/2020 Application Form License Tax Form
12/03/2020 Letter Codes Residential Plan Review
12/04/2020 Plot Plan Approved Plot Plan
12/04/2020 Letter Letter from Engineer for basement
12/15/2020 Approved Plans Approved Drawings
12/15/2020 Receipt Receipt for transaction:2020-008024
12/15/2020 Letter DS Building Permit
01/26/2021 Final_2021_01_22_SiteObv_LSMO_Gale Homes
02/05/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
10/13/2021 Letter INSPECTION SUMMARY
10/14/2021 2021_10_14 Gale Homes_Lot 1479 Winterset Valley_Permit Sets_sealed
11/02/2021 DW FRAMING REPORT McBride 211 NW Carson
11/02/2021 Letter INSPECTION SUMMARY
11/02/2021 Letter INSPECTION SUMMARY
11/02/2021 Letter INSPECTION SUMMARY
11/03/2021 Letter INSPECTION SUMMARY
11/15/2021 Letter INSPECTION SUMMARY
11/16/2021 Letter INSPECTION SUMMARY
11/16/2021 Letter INSPECTION SUMMARY
11/24/2021 Letter INSPECTION SUMMARY
11/24/2021 Letter INSPECTION SUMMARY
05/23/2022 Letter Codes 180 Day Letter
06/01/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/15/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter INSPECTION SUMMARY
06/21/2022 Letter Codes Final Certificate of Occupancy
06/21/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home