Summary
PRRES20204527
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
12/01/2020
12/07/2020
05/31/2021
08/10/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/09/2020 12/07/2020
Kim Brennan
Lot elevations
Corrective Action Required
12/07/2020

Existing and finish elevations at all property corners must be provided on the plot plan. Please provide this elevation for the south/east corner of the lot.
Residential Plan Review Approved 12/09/2020 12/07/2020
Kim Brennan
Plot Plan Review Rejected 12/03/2020 12/02/2020
Kim Brennan
Lot elevations
Corrective Action Required
12/02/2020

Existing and finish elevations at all property corners must be provided on the plot plan. Please provide this elevation for the south/east corner of the lot.
Residential Plan Review Approved 12/03/2020 12/01/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $998.60 $998.60 Paid 12/07/2020
Right of Way Permit Fee $80.00 $80.00 Paid 12/07/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/07/2020
8331507-Sewer Connection Fee $360.00 $360.00 Paid 12/07/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 12/07/2020
Water Meter Fee $455.54 $455.54 Paid 12/07/2020
Not Ready Inspection Fee $50.00 $50.00 Paid 05/10/2021
3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 05/10/2021
3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 05/10/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 2/24/2021 2/24/2021 02/24/2021
Misc
Corrective Action Required
02/24/2021
-UNABLE TO INSPECT ALL DWV DUE TO MUD WATER COVER, PUMP OUT WATER OR SCHEDULE WHEN CONDITIONS ALLOW
Footing Inspection - Residential Failed 2/24/2021 2/24/2021 02/24/2021
Misc
Corrective Action Required
02/24/2021
- FOOTING PERFORMED WITHOUT INSPECTION -SUBMIT ENGINEER REPORT
Underslab Plumbing Inspection - Residential Failed 2/26/2021 2/26/2021 02/26/2021
Misc
Corrective Action Required
02/24/2021
-UNABLE TO INSPECT ALL DWV DUE TO MUD WATER COVER, PUMP OUT WATER OR SCHEDULE WHEN CONDITIONS ALLOW 2/26/21-BASEMENT COVERED WITH TARPS UNABLE TO SEE ANY DWV, UNCOVER BASEMENT AND RESCHEDULE INSPECTION
Underslab Plumbing Inspection - Residential Passed 3/2/2021 3/2/2021 03/02/2021
Misc
Resolved
03/02/2021
All Rough Inspection - Residential Failed 4/22/2021 4/22/2021 04/22/2021
Misc
Corrective Action Required
04/22/2021
-H2.5 hold downs or approved truss structural screws at all truss ends throughout -Fireblock at chase in garage, seal all gaps at fireplace material -Truss hold downs at all hip trusses -12” oc nailing at all abutting and intersecting wall corners (braced wall panels) -Fireblock dead space at master bed hall/shower -see (3) 2x4 jack studs between window units at master bed, kitchen, living room, front bed, all cut short from header -seal gas line floor penetration at fireplace -support front covered porch beams at garage and front bedroom -2x4s cut short at rear covered porch beams support at living room windows, replace or shim with approved shims -Fireblock all tub/shower traps -seal unused top plate penetration at west wall, rear bed -LIB bracing, all locations per plans -attic access at garage per plans -CS-PF per plans at dining room and living room windows, extend braced wall panel to interior edge of wall at dining room -(4) 2x4 stud packs at all girder truss bearing ends per plans -All truss hangers per plans -All truss lateral bracing per plans -Land all NM to boxes at basement landing -Address sump pump and AC line bored through joist less than 2” from end of joist at SE corner basement -Joist hangers required at joist to stair rim connection, over 4’ -Nail all straps embedded in concrete at garage portal -Allow for inspection of nail pattern at garage PFH -Nail all exterior sheathing per plans,6” edge, 12” field -Flashing at garage door trim
All Rough Inspection - Residential Not Ready 4/26/2021 4/26/2021 04/26/2021
Misc
Corrective Action Required
04/22/2021
4/26/21 - NOT READY FOR INSPECTION, TRADES HAD JUST ARRIVED ON SITE TO BEGIN WORKING ON CORRECTIONS AT TIME OF INSPECTION. RESCHEDULE WHEN COMPLETE -H2.5 hold downs or approved truss structural screws at all truss ends throughout -Fireblock at chase in garage, seal all gaps at fireplace material -Truss hold downs at all hip trusses -12” oc nailing at all abutting and intersecting wall corners (braced wall panels) -Fireblock dead space at master bed hall/shower -see (3) 2x4 jack studs between window units at master bed, kitchen, living room, front bed, all cut short from header -seal gas line floor penetration at fireplace -support front covered porch beams at garage and front bedroom -2x4s cut short at rear covered porch beams support at living room windows, replace or shim with approved shims -Fireblock all tub/shower traps -seal unused top plate penetration at west wall, rear bed -LIB bracing, all locations per plans -attic access at garage per plans -CS-PF per plans at dining room and living room windows, extend braced wall panel to interior edge of wall at dining room -(4) 2x4 stud packs at all girder truss bearing ends per plans -All truss hangers per plans -All truss lateral bracing per plans -Land all NM to boxes at basement landing -Address sump pump and AC line bored through joist less than 2” from end of joist at SE corner basement -Joist hangers required at joist to stair rim connection, over 4’ -Nail all straps embedded in concrete at garage portal -Allow for inspection of nail pattern at garage PFH -Nail all exterior sheathing per plans,6” edge, 12” field -Flashing at garage door trim
All Rough Inspection - Residential Failed 4/27/2021 4/27/2021 04/27/2021
Misc
Corrective Action Required
04/26/2021
-(4) 2x4 stud packs at all girder truss bearing ends per plans -Address sump pump and AC line bored through joist less than 2” from end of joist at SE corner basement -Joist hangers required at joist to stair rim connection, over 4’ -Nail all exterior sheathing per plans,6” edge, 12” field -see south side of house
All Rough Inspection - Residential Failed 4/28/2021 4/28/2021 04/28/2021
Misc
Corrective Action Required
04/27/2021
-Address sump pump and AC line bored through joist less than 2” from end of joist at SE corner basement, follow repairs per engineer letter instructions **OK TO INSULATE**
All Rough Inspection - Residential Failed 4/29/2021 4/29/2021 04/29/2021
Misc
Corrective Action Required
04/28/2021
-Address sump pump and AC line bored through joist less than 2” from end of joist at SE corner basement, follow repairs per engineer letter instructions -INSTALL SIMPSON STRONG DRIVE SD CONNECTOR SCREWS ON CTS218 STRAPS PER ENGINEER LETTER- **OK TO INSULATE**
All Rough Inspection - Residential Passed 4/30/2021 4/30/2021 04/30/2021
Misc
Resolved
04/30/2021
Gas Service Inspection - Residential Passed 5/5/2021 5/5/2021 05/05/2021
Electrical Service Inspection Passed 5/5/2021 5/5/2021 05/05/2021
Sewer Service Inspection - R Passed 5/26/2021 05/26/2021
Erosion Control Inspection Residential Failed 5/26/2021 5/26/2021 05/26/2021
Misc
Resolved
05/26/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/26/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Water Service Inspection - R Passed 5/28/2021 (8:30) 5/28/2021 05/28/2021
Driveway Inspection Partial 6/4/2021 6/4/2021 06/04/2021
Misc
Informational
06/04/2021
6/4/21- 6in depth, told Bob to place expansion on the curb line, tool or expansion on the 11ft easement line and to use KCCMB Mix. Driveway is good to pour.
Driveway Inspection Passed 6/8/2021 6/8/2021 06/08/2021
Misc
Informational
06/04/2021
6/4/21- 6in depth, told Bob to place expansion on the curb line, tool or expansion on the 11ft easement line and to use KCCMB Mix. Driveway is good to pour.
Misc
Informational
06/08/2021
6/8/21- Driveway has been poured, expansion joint on the curb and 11ft easement.
Footing Inspection - Residential Passed 06/25/2021
Misc
Resolved
06/25/2021
Occupancy Inspection - Codes Residential Failed 6/25/2021 6/25/2021 06/25/2021
Misc
Corrective Action Required
06/25/2021
-Address numbers on house must contrast against background color -Final grade and sod -Splash blocks at all downspout and sump pump locations, min 36” discharge from foundation -seal all penetrations in siding, seal along top of AC disconnect and meter can -Install cover plate floor receptacle at front entry -Install receptacle/cover plate at fireplace, no setback allowed with box at combustible material, move box or add spark ring -cover plates all switches and receptacles -Open ceiling penetrations throughout -GFCI protection required at laundry washer circuit -support garage stair landing at foundation wall -Hot water heater must be operational
Occupancy Inspection - Codes Residential Temporary C of O 7/27/2021 7/27/2021 07/27/2021
Misc
Corrective Action Required
06/25/2021
-Install extension at sump pump discharge -set sewer tracer to box and set box at grade -Ensure 6” of fall from foundation within first 10’ around perimeter of foundation, foundation has negative slope on east side of house and along retaining wall **OK FOR TCO - TCO EXPIRES 8/13/21**
Plot Plan Inspection Passed 8/10/2021 8/10/2021 08/10/2021
Erosion Control Inspection Residential Passed 8/10/2021 8/10/2021 08/10/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/10/2021
Occupancy Inspection - Codes Residential Full C of O 8/10/2021 8/10/2021 08/10/2021
Misc
Resolved
08/10/2021
Documents & Images
Date Uploaded File Type Document Name
12/01/2020 Application Form Permit Application and License Tax Form
12/01/2020 Approved Plans Approved Drawings
12/02/2020 Approved Plans Approved Truss Layout
12/02/2020 Approved Plans Approved Truss Package
12/02/2020 Letter Codes Residential Plan Review
12/07/2020 Plot Plan Approved Plot Plan
12/07/2020 Receipt Receipt for transaction:2020-007883
12/07/2020 Letter DS Building Permit
02/24/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
02/26/2021 Letter INSPECTION SUMMARY
02/26/2021 Lot 23 Hawthorne Ridge footing
03/02/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
04/26/2021 Letter INSPECTION SUMMARY
04/27/2021 Letter INSPECTION SUMMARY
04/27/2021 23 Hawthorne Ridge Floor Joist Holes Letter
04/28/2021 Letter INSPECTION SUMMARY
04/29/2021 Letter INSPECTION SUMMARY
04/30/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/10/2021 Receipt Receipt for transaction:2021-002778
05/26/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
05/28/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter Codes Temporary Certificate of Occupancy
08/10/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter Field Certificate of Occupancy
08/10/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home