Permit Application Status

PRRES20204325


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204325
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 12/31/2020 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 01/06/2021 12:00 AM by username 'Patrick Schonfeldt'.
11/16/2020
11/20/2020
05/16/2021
07/16/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/24/2020 11/20/2020
Kim Brennan
Lot elevations
Corrective Action Required
11/20/2020

Existing and finish elevations at all property corners must be provided on the plot plan. Please provide elevations for the north, rear corner of the lot
Residential Plan Review Approved 11/24/2020 11/20/2020
Kim Brennan
Plot Plan Review Rejected 11/18/2020 11/17/2020
Kim Brennan
Lot elevations
Corrective Action Required
11/17/2020

Existing and finish elevations at all property corners must be provided on the plot plan. Please provide elevations for the north, rear corner of the lot
Residential Plan Review Approved 11/18/2020 11/16/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,356.07 $1,356.07 Paid 11/20/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/20/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/20/2020
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 11/20/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 11/20/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 11/20/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 11/20/2020
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 05/06/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/12/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 12/21/2020 (2:30) 12/21/2020 12/21/2020
Misc
Corrective Action Required
12/21/2020
-FOOTING SET ON COMPACTED FILL - SUBMIT ENGINEER REPORT(S)
Footing Inspection - Residential Failed - Stop Work 12/31/2020
Misc
Corrective Action Required
12/21/2020
-FOOTING SET ON COMPACTED FILL - SUBMIT ENGINEER REPORT(S) -FOOTING POURED WITHOUT APPROVAL ON COMPACTED FILL - NO ENGINEER REPORT(S) SUBMITTED - STOP WORK ISSUED
Footing Inspection - Residential Passed 01/06/2021
Misc
Resolved
01/06/2021
Underslab Plumbing Inspection - Residential Failed 1/15/2021 1/15/2021 01/15/2021
Misc
Corrective Action Required
01/15/2021
-INSTALL INTERIOR DRAIN TILE
Sewer Service Inspection - R Passed 1/15/2021 (1:00) 1/15/2021 01/15/2021
Water Service Inspection - R Passed 1/19/2021 (10:45) 1/19/2021 01/19/2021
Underslab Plumbing Inspection - Residential Passed 1/20/2021 1/20/2021 01/20/2021
Misc
Resolved
01/20/2021
Erosion Control Inspection Residential Failed 01/20/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/20/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -INSTALL SILT FENCE AT FRONT OF LOT
Electrical Service Inspection Failed 3/26/2021 3/26/2021 03/26/2021
Misc
Corrective Action Required
03/26/2021
-Color code/label GEC at service panel
Gas Service Inspection - Residential Passed 3/26/2021 3/26/2021 03/26/2021
All Rough Inspection - Residential Failed 3/26/2021 3/26/2021 03/26/2021
Misc
Corrective Action Required
03/26/2021
-Unable to inspect and verify embedded straps in concrete and PFH nail pattern for garage portal due to siding cover -Seal all top and bottom plate penetrations -Seal all through floor penetrations -Fireblock all tub and shower traps -Anchor bolts required within 12” of plate break in garage and basement -complete furred down in garage -Fireblock rim joist penetrations in garage -H2.5 truss hold downs at all trusses throughout -security blocking at exterior doors -Fireblock HVAC chase at pantry -Header off at joist with hanger at HVAC box out in pantry, joist supported by non load bearing wall -Snow blocking at pantry and 2nd floor -Secure all vertical DWV 2” or less at mid point -secure gas flex line at fireplace -All truss bracing per plans -All truss hangers per plans -3” SCH steel column at W10x17 steel beam in garage per plans -LIB bracing all locations per plans -(2) 2x4 jack studs at garage/owner entry doors per plans -(2) 2x12 header at 1st floor sliding door per plans -see bedroom #5 1st floor, address over notched (2)2x10 rim for covered porch, no connection of intersecting braced wall corner to top plate -(4)2x4 stud packs at all girder truss bearing ends per plans -Fireblock HVAC chase master bed -Master bath tub/DWV install,complete DWV -Color code/label GEC at service panel -Anchor all SCH steel columns to floor in basement -B vent at furnace requires 1” clearance from combustibles, secure NM off B vent -Add triple joist hanger to (3) 2x10 at stair rim, currently supported by non load bearing stair wall -W10x39 steel beam to be supported at bearing end by (6) 2x6 stud pack per plans basement -deck ledger attachment to house per code -(2) bolts at rim/post connection per code at deck -bolt inner ply of rim to ledger and add angel clip to outer ply at deck -full height 6x6 cedar posts at covered deck per plans
Electrical Service Inspection Passed 4/9/2021 4/9/2021 04/09/2021
Misc
Resolved
04/09/2021
-Color code/label GEC at service panel
All Rough Inspection - Residential Failed 4/19/2021 4/19/2021 04/19/2021
Misc
Corrective Action Required
03/26/2021
-Seal all top plate penetrations - see kitchen exterior wall -land NM to boxes at 1st floor stair wall, removed for corrections -bed#5 1st floor ceiling - correct floor joist,pex removed for correction -All truss hangers per plans -see garage -(2) 2x4 jack studs at garage/owner entry doors per plans -see bedroom #5 1st floor, address over notched (2)2x10 rim for covered porch -cannot verify if over notched rim has been addressed due to oversprayed expansion foam cover -Land NM to box for jacuzzi tub, jacuzzi tub installed since last inspection -(4)2x4 stud packs at all girder truss bearing ends per plans - see girder at bath#2 2nd floor exterior wall -B vent at furnace requires 1” clearance from combustibles, secure NM off B vent -(2) bolts at each rim/post connection per code at deck -full height 6x6 cedar posts at covered deck per plans
All Rough Inspection - Residential Failed 4/28/2021 4/28/2021 04/28/2021
Misc
Corrective Action Required
04/19/2021
-see bedroom #5 1st floor, address over notched (2)2x10 rim for covered porch -cannot verify if over notched rim has been addressed due to oversprayed expansion foam cover **OK TO INSULATE**
All Rough Inspection - Residential Passed 4/29/2021 4/29/2021 04/28/2021
Misc
Resolved
04/28/2021
Driveway Inspection Failed 5/19/2021 05/20/2021
Misc
Informational
05/20/2021
The forms look good and is ready to pour except for the fact that it is raining and the subgrage is too wet to pour concrete. I am failiing because of rain.
Sidewalk Inspection Failed 5/19/2021 05/20/2021
Misc
Informational
05/20/2021
Everything is set up fine, rock is good and forms are good, Subgrade it too wet. Please call in another inspection when subgrade is dried out.
Misc
Informational
05/20/2021
Everything is set up fine, rock is good and forms are good, Subgrade it too wet. Please call in another inspection when subgrade is dried out.
Sidewalk Inspection Passed 5/21/2021 5/21/2021 05/24/2021
Driveway Inspection Passed 5/21/2021 5/21/2021 05/24/2021
Misc
Informational
05/20/2021
The forms look good and is ready to pour except for the fact that it is raining and the subgrage is too wet to pour concrete. I am failiing because of rain.
Occupancy Inspection - Codes Residential Failed 6/28/2021 6/28/2021 06/28/2021
Misc
Corrective Action Required
06/28/2021
-Final grade and sod -splash blocks at downspout and sump pump discharge, min 36" discharge from foundation -Install oven, no receptacle seen in cabinet -Interconnection required of all smoke detectors- see 2nd floor bedroom S side -cover plates required master bath vanity receptacles -security screws at basement walkout -clip off set screw head on anti siphon, see basement spigot at main water line
Occupancy Inspection - Codes Residential Not Ready 7/9/2021 7/9/2021 07/09/2021
Misc
Corrective Action Required
06/28/2021
-Final grade and sod -splash blocks at downspout and sump pump discharge, min 36" discharge from foundation -Built in ovens req for occ, receptacle in cabinet at reinspection with exposed NM -Interconnection required of all smoke detectors- see 2nd floor bedroom S side -cover plates required master bath vanity receptacles -security screws at basement walkout -clip off set screw head on anti siphon, see basement spigot at main water line **7/9/21 - INTERIOR ISSUES NOT ADDRESSED AT REINSPECTION, NOT READY FEE ADDED**
Occupancy Inspection - Codes Residential Temporary C of O 7/13/2021 7/13/2021 07/13/2021
Misc
Corrective Action Required
07/09/2021
-Final grade and sod -splash blocks at downspout and sump pump discharge, min 36" discharge from foundation **OK FOR TCO - TCO EXPIRES 7/28/21**
Occupancy Inspection - Codes Residential Failed 7/15/2021 7/15/2021 07/15/2021
Misc
Corrective Action Required
07/13/2021
-Obtain lawn irrigation system permit -splash blocks at downspout and sump pump discharge, min 36" discharge from foundation -Uncover manhole at rear corner of lot as shown on plot plan **OK FOR TCO - TCO EXPIRES 7/28/21**
Erosion Control Inspection Residential Passed 07/15/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/15/2021
Plot Plan Inspection Failed 7/15/2021 7/15/2021 07/15/2021
Misc
Corrective Action Required
07/15/2021
-Uncover manhole at rear corner of lot as shown on plot plan
Plot Plan Inspection Passed 7/16/2021 7/16/2021 07/16/2021
Misc
Resolved
07/16/2021
Occupancy Inspection - Codes Residential Full C of O 7/16/2021 7/16/2021 07/16/2021
Misc
Resolved
07/16/2021
Documents & Images
Date Uploaded File Type Document Name
11/16/2020 Application Form Permit Application and license tax form
11/16/2020 Approved Plans Approved Drawings
11/16/2020 Approved Plans Approved Truss Layout
11/16/2020 Approved Plans Approved Truss Package
11/17/2020 Letter Codes Residential Plan Review
11/20/2020 Plot Plan Approved Plot Plan
11/20/2020 Receipt Receipt for transaction:2020-007671
11/20/2020 Letter DS Building Permit
12/21/2020 Letter INSPECTION SUMMARY
12/31/2020 Letter Stop Work Order
12/31/2020 728AEE43-5D34-41CA-94C1-5123629D90EF.jpeg
12/31/2020 Letter Stop Work Order
01/06/2021 RR93 Footing Inspection
01/06/2021 Letter INSPECTION SUMMARY
01/15/2021 Letter INSPECTION SUMMARY
01/15/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter INSPECTION SUMMARY
04/09/2021 Letter INSPECTION SUMMARY
04/19/2021 Letter INSPECTION SUMMARY
04/28/2021 Letter INSPECTION SUMMARY
04/28/2021 RR93-Front porch beam notch letter
04/28/2021 Letter INSPECTION SUMMARY
05/06/2021 Receipt Receipt for transaction:2021-002629
05/20/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
06/28/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/12/2021 Receipt Receipt for transaction:2021-005535
07/13/2021 Letter Codes Temporary Certificate of Occupancy
07/15/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
07/16/2021 Letter INSPECTION SUMMARY
07/16/2021 Letter Field Certificate of Occupancy
07/16/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home