Permit Application Status

PRRES20204198


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204198
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - UNFINISHED BASEMENT - COVERED DECK
11/06/2020
11/19/2020
05/10/2021
06/27/2022
Locations
Contacts
ROESER HOMES LLC, Address:11415 STRANG LINE RD, Phone:(913) 220-7477  
MELISSA@ROESERHOMES.COM  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
ELECTRICAL INVESTMENTS, Address:8014 REEDER ST, Phone:(816) 210-1597  
MORGAN MILLER PLUMBING, Address:13911 NORBY RD, Phone:(816) 765-4843  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 11/23/2020 11/19/2020
Dylan Eppert
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
11/19/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) PLEASE LABEL THE FOLLOWING SQUARE FOOTAGES: 1. UNFINISHED BASEMENT 2. GARAGE 3. COVERED DECK
18 Identify type of roof/truss package (if used) complete with layout, comp
Corrective Action Required
11/19/2020

Identify type of roof/truss package (if used) complete with layout, component design, fastening details, blocking and sheathing requirements. (IRC Section 802.10) DEFERRED I HAVE RECEIVED THE TRUSS LAYOUT BUT STILL NEED THE TRUSS PACKAGE WITH THE SPEC SHEETS THAT ARE STAMED BY A DESIGN PROFESSIONAL.
Plot Plan Review Approved 11/23/2020 11/19/2020
Dylan Eppert
Sidewalks
Corrective Action Required
11/19/2020

Sidewalks with dimensions must be provided on the plot plan. PLAT SHOWS 5' SIDEWALK NOT 4' PLEASE REVISE.
Drainage swales
Corrective Action Required
11/19/2020

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide
Basement opening elevations
Corrective Action Required
11/19/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Plot Plan Review Rejected 11/10/2020 11/11/2020
Dylan Eppert
Sidewalks
Corrective Action Required
11/11/2020

Sidewalks with dimensions must be provided on the plot plan. PLAT SHOWS 5' SIDEWALK NOT 4' PLEASE REVISE.
Drainage swales
Corrective Action Required
11/11/2020

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide
Basement opening elevations
Corrective Action Required
11/11/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Residential Plan Review Rejected 11/10/2020 11/11/2020
Dylan Eppert
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
11/11/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) PLEASE LABEL THE FOLLOWING SQUARE FOOTAGES: 1. UNFINISHED BASEMENT 2. GARAGE 3. COVERED DECK
18 Identify type of roof/truss package (if used) complete with layout, comp
Corrective Action Required
11/11/2020

Identify type of roof/truss package (if used) complete with layout, component design, fastening details, blocking and sheathing requirements. (IRC Section 802.10) DEFERRED I HAVE RECEIVED THE TRUSS LAYOUT BUT STILL NEED THE TRUSS PACKAGE WITH THE SPEC SHEETS THAT ARE STAMED BY A DESIGN PROFESSIONAL.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,565.44 $1,565.44 Paid 11/30/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/30/2020
8331507-Sewer Connection Fee $630.00 $630.00 Paid 11/30/2020
Water Meter Fee $455.54 $455.54 Paid 11/30/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 11/30/2020
Right of Way Permit Fee $80.00 $80.00 Paid 11/30/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 12/15/2020 (10:30) 12/15/2020 12/15/2020
Misc
Corrective Action Required
12/15/2020
Minimum 8” depth throughout per plan
Erosion Control Inspection Residential Failed 12/15/2020
Misc
Corrective Action Required
12/15/2020
-Establish erosion control methods with in two business days -provide building address -no further inspections until complete
Footing Inspection - Residential Passed 12/15/2020 (11:30) 12/15/2020 12/15/2020
Misc
Resolved
12/15/2020
Minimum 8” depth throughout per plan
Sewer Service Inspection - R Passed 1/20/2021 (1:00) 1/20/2021 01/20/2021
Water Service Inspection - R Passed 1/21/2021 (3:15) 1/21/2021 01/21/2021
Erosion Control Inspection Residential Failed 01/21/2021
Misc
Corrective Action Required
12/15/2020
Immediate Street clean up required
Erosion Control Inspection Residential Failed 01/26/2021
Misc
Resolved
01/26/2021
Immediate Street clean up required
Misc
Corrective Action Required
01/26/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days, re-establish at front curb line -provide and maintain gravel filter -no further inspections until issues are resolved
Underslab Plumbing Inspection - Residential Failed 1/26/2021 1/26/2021 01/26/2021
Misc
Corrective Action Required
01/26/2021
Connect interior underslab drain tile to sump pit
Underslab Plumbing Inspection - Residential Passed 2/1/2021 2/1/2021 02/01/2021
Misc
Resolved
02/01/2021
Connect interior underslab drain tile to sump pit
Erosion Control Inspection Residential Failed 2/1/2021 2/1/2021 02/01/2021
Misc
Corrective Action Required
01/26/2021
-Erosion control requires continuous maintenance. -Clean debris form storm inlet -Port a John not to be placed on top of storm inlet -Clean trash from site
Erosion Control Inspection Residential Failed 03/10/2021
Misc
Corrective Action Required
02/01/2021
-NO Erosion control -no further inspections until issues are resolved
Erosion Control Inspection Residential Failed 05/18/2021
Misc
Corrective Action Required
03/10/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -remove debris from stormwater inlet -no further inspections until issues are resolved
All Rough Inspection - Residential Failed 7/2/2021 7/2/2021 07/02/2021
Misc
Corrective Action Required
07/02/2021
portal ok, deck rafters and post columns covered. no inspecition.
All Rough Inspection - Residential Failed 7/27/2021 07/27/2021
Misc
Corrective Action Required
07/02/2021
portal ok, , address erosion control. cut over grown vegetation to max 10" in height , contain all trash and debris. Provide report from truss manufacture on screws holding down truss on covered deck. Screws are through the siding and not at the correct height and location through both tope plates.
All Rough Inspection - Residential Failed 8/6/2021 8/6/2021 08/06/2021
Misc
Corrective Action Required
07/27/2021
portal ok, Addresss the mart trim ledger supporting trusses.
All Rough Inspection - Residential Failed 8/30/2021 8/30/2021 08/30/2021
Misc
Corrective Action Required
08/06/2021
-Garage portal ok -Rear patio roof ok to cover
All Rough Inspection - Residential Failed 10/27/2021 10/27/2021 10/27/2021
Misc
Corrective Action Required
08/30/2021
-Garage portal ok -Rear patio roof ok to cover
Misc
Corrective Action Required
10/27/2021
-Maintain erosion control silt fence at front of lot, address before rescheduling reinspection -Fireblock between top plates at dbl wall at kitchen fridge/mud room -dbl floor joists all locations at kitchen per plans, also dbl joist has been cut for DWV -security blocking at front door -protect NM within 6’ of attic access 2nd floor -All Truss hangers per plans -Dbl top plates require 24” offset between plate breaks, also address top plate connection at corner intersection- 2nd floor East bedroom west corner -add joist hanger at sgl joist to header connection, right of furnace at basement
Electrical Service Inspection Passed 10/27/2021 10/27/2021 10/27/2021
Gas Service Inspection - Residential Passed 10/27/2021 10/27/2021 10/27/2021
Erosion Control Inspection Residential Failed 10/27/2021 10/27/2021 10/27/2021
Misc
Corrective Action Required
05/18/2021
-Maintain erosion control silt fence at front of lot NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL ADDRESSED
All Rough Inspection - Residential Failed 11/17/2021 11/17/2021 11/17/2021
Misc
Corrective Action Required
10/27/2021
-Garage portal ok -Rear patio roof ok to cover
Misc
Corrective Action Required
10/27/2021
-security blocking at front door -Dbl top plates require 24” offset between plate breaks, -2nd floor East bedroom west corner nail off
All Rough Inspection - Residential Passed 11/19/2021 11/19/2021
Misc
Informational
11/19/2021
-Garage portal ok -Rear patio roof ok to cover
Misc
Resolved
11/19/2021
Driveway Inspection Partial 12/13/2021 12/13/2021 12/13/2021
Misc
Informational
12/13/2021
Driveway was framed up with aggregate in and compacted. 12/13 ES
Sidewalk Inspection Partial 12/13/2021 12/13/2021 12/13/2021
Misc
Informational
12/13/2021
Sidewalk was framed up with aggregate in and compacted. 12/13 ES
Sidewalk Inspection Passed 12/17/2021 12/17/2021 12/17/2021
Misc
Informational
12/13/2021
Sidewalk was framed up with aggregate in and compacted. 12/13 ES
Misc
Informational
12/17/2021
Sidewalk meets LS and Ada specs. 12/17/21 ES
Driveway Inspection Passed 12/17/2021 12/17/2021 12/17/2021
Misc
Informational
12/13/2021
Driveway was framed up with aggregate in and compacted. 12/13 ES
Misc
Informational
12/17/2021
Driveway meets LS and Ada specs. 12/17/21 ES
Erosion Control Inspection Residential Failed 3/11/2022 03/11/2022
Misc
Corrective Action Required
10/27/2021
-Maintain erosion control silt fence, swaddles at front of lot NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL ADDRESSED
Occupancy Inspection - Codes Residential Failed 3/11/2022 3/11/2022 03/11/2022
Miscellaneous Correction
Corrective Action Required
03/11/2022
- irrigation permit and back flow certification if installing - Final grading and sod - Splash blocks - Sump discharge 36” from foundation - Seal exterior penetrations - Provide secondary lock on owner entry back door - Provide secondary lock on front door - Provide spark rings at kitchen counter outlets - Fire block penetration for gas line in garage - Label all non- GFCI outlets - Provide ladder for basement Egress window - Complete install of water heaters, no Bvent , no gas. - Security screws in doors MAINTAIN EROSION CONTROL
Erosion Control Inspection Residential Failed 3/15/2022 03/15/2022
Misc
Corrective Action Required
03/11/2022
-Maintain erosion control silt fence, swaddles at front of lot NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL ADDRESSED
Occupancy Inspection - Codes Residential Failed 3/15/2022 3/15/2022 03/15/2022
Miscellaneous Correction
Corrective Action Required
03/11/2022
- irrigation permit and back flow certification if installing - Final grading and sod - Splash blocks - Sump discharge 36” from foundation - Seal exterior penetrations - Provide secondary lock on owner entry back door - Provide secondary lock on front door - Provide spark rings at kitchen counter outlets - Fire block penetration for gas line in garage - Label all non- GFCI outlets - Provide ladder for basement Egress window - Complete install of water heaters, no Bvent , no gas. - Security screws in doors MAINTAIN EROSION CONTROL
Miscellaneous Correction
Corrective Action Required
03/15/2022
No inspection done 3/15/22 - no erosion control - no secondary lock on front door Did not go in.
Occupancy Inspection - Codes Residential Temporary C of O 3/30/2022 3/30/2022 03/30/2022
Miscellaneous Correction
Corrective Action Required
03/15/2022
- irrigation permit and back flow certification if installing - Final grading and sod - Splash blocks MAINTAIN EROSION CONTROL
Miscellaneous Correction
Resolved
03/30/2022
Erosion Control Inspection Residential Passed 3/30/2022 03/30/2022
Erosion Control Inspection Residential Passed 06/15/2022
Occupancy Inspection - Codes Residential Failed 6/23/2022 6/23/2022 06/23/2022
Miscellaneous Correction
Corrective Action Required
03/30/2022
- UNCOVER WATER METER AND BRING ACCESS TO GRADE LEVEL WITH METER 14 -18' FROM TOP.
Plot Plan Inspection Passed 06/27/2022
Occupancy Inspection - Codes Residential Full C of O 6/27/2022 6/27/2022 06/27/2022
Miscellaneous Correction
Resolved
06/27/2022
Documents & Images
Date Uploaded File Type Document Name
11/06/2020 License_Tax_Application
11/06/2020 Final Plot Plan - Lot 1464 WV
11/06/2020 Engineered Truss Plans - Lot 1464 WV
11/09/2020 Engineered Plans - Lot 1464 WV
11/09/2020 Residental Permit Application 2019
11/11/2020 Drawing APPROVED TRUSS LAYOUT
11/11/2020 Letter Codes Residential Plan Review
11/19/2020 Revised Final Plot Plan - Lot 1464 WV
11/19/2020 Revised Engineered Plans - Lot 1464 WV
11/19/2020 Plans APPROVED PLOT PLAN
11/19/2020 Plans APPROVED HOUSE PLAN
11/19/2020 Receipt Receipt for transaction:2020-007668
11/19/2020 Letter DS Building Permit
11/20/2020 Engineered Sealed Package - Lot 1464 WV
11/20/2020 Engineered Truss Plans - Lot 1464 WV
11/30/2020 Receipt Receipt for transaction:2020-007750
12/15/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/21/2020 Specifications APPROVED ROOF TRUSS PACKAGE
12/21/2020 Plans APPROVED REVISED HOUSE PLANS
01/20/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
02/01/2021 Letter INSPECTION SUMMARY
02/01/2021 Letter INSPECTION SUMMARY
03/04/2021 125 NW Mackenzie Dr_ALL SLAB INSP_2021-03-03
03/10/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
07/02/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
11/16/2021 DW FRAMING ADDENDUM Roanoke Spec Lot 1464 WV 125 NW MacKenzie Dr
11/17/2021 Letter INSPECTION SUMMARY
11/19/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
12/13/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
03/11/2022 Letter INSPECTION SUMMARY
03/11/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/15/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter Codes Temporary Certificate of Occupancy
03/30/2022 Letter INSPECTION SUMMARY
06/14/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
06/15/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter Codes Final Certificate of Occupancy
06/27/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home