Permit Application Status

PRRES20204075


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204075
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
10/30/2020
11/04/2020
04/11/2022
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
CLASS ONE ELECTRIC INC, Address:PO BOX 24343, Phone:(913) 915-1767  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/03/2020 11/04/2020
Dylan Eppert
Residential Plan Review Approved 11/03/2020 11/04/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,429.67 $1,429.67 Paid 11/04/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 11/04/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 11/04/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 11/04/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/04/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/04/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/05/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/28/2020 (2:30) 12/28/2020 12/28/2020
Erosion Control Inspection Residential Failed 01/07/2021
Misc
Informational
01/07/2021
1-7-21 3:33pm There is no silt fence up on the back side of the lot and there is a creek.
Underslab Plumbing Inspection - Residential Failed 1/29/2021 1/29/2021 01/29/2021
Misc
Corrective Action Required
01/29/2021
Complete installation of interior underslab drain tile with positive or neutral slope throughout and connect to sump pit
Erosion Control Inspection Residential Failed 01/29/2021
Misc
Resolved
01/29/2021
1-7-21 3:33pm There is no silt fence up on the back side of the lot and there is a creek.
Misc
Corrective Action Required
01/29/2021
Immediate Street clean up required
Erosion Control Inspection Residential Passed 02/03/2021
Misc
Resolved
02/03/2021
Immediate Street clean up required
Underslab Plumbing Inspection - Residential Passed 2/3/2021 2/3/2021 02/03/2021
Misc
Resolved
02/03/2021
Complete installation of interior underslab drain tile with positive or neutral slope throughout and connect to sump pit
Erosion Control Inspection Residential Failed 03/10/2021
Misc
Corrective Action Required
03/10/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -Immediate street cleanup required -No further inspections until issues are resolved
Rough Framing Inspection - Residential Failed 3/10/2021 3/10/2021 03/10/2021
Misc
Corrective Action Required
03/10/2021
-two bottom plates per plan 1/S4.0 -two rows of 16D sinker nails 3" OC at braced wall panel top plates per plan, see section view of detail 1/S4.0
Erosion Control Inspection Residential Failed 03/17/2021
Misc
Corrective Action Required
03/10/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -Immediate street cleanup required -No further inspections until issues are resolved
Rough Framing Inspection - Residential Partial 4/5/2021 4/5/2021 04/05/2021
Misc
Resolved
04/05/2021
-two bottom plates per plan 1/S4.0 -two rows of 16D sinker nails 3" OC at braced wall panel top plates per plan, see section view of detail 1/S4.0
Piers/Caissons Inspection - Residential Passed 4/5/2021 4/5/2021 04/05/2021
Gas Service Inspection - Residential Failed 4/6/2021 4/6/2021 04/06/2021
Misc
Corrective Action Required
04/06/2021
4/6/21 **SPOKE WITH CRAIG ON GAS SERVICE INSPECTION PROCESS, WILL CALL BACK IN WHEN READY**
Sewer Service Inspection - R Passed 5/7/2021 (1:00) 5/7/2021 05/07/2021
Water Service Inspection - R Passed 5/12/2021 (10:00) 5/12/2021 05/12/2021
All Rough Inspection - Residential Failed 5/24/2021 5/24/2021 05/24/2021
Misc
Corrective Action Required
05/24/2021
-deck not ready for inspection -Rafter bearing per plan throughout -Rafter to joist connection per plan throughout -Tighten anchor bolts throughout -Top plate spices to offset minimum 24 inches -Fireblock vertical to horizontal at furr out in garage -Fireblock vertical to horizontal at all soffit to wall connections -Furr out return pan in garage ceiling for insulation -Provide joist hangers at floor joist connection to LVL above utility -Provide minimum 16g galvanized metal ties 1.5” wide at over bored top plates of load bearing walls. Fasten ties across and to the plate at each side of the opening with minimum 4-10dx1.5” at each side of straps. The metal tie must extend a minimum of 6” past the opening. See figure R602.6.1 -Braced wall method CS-PF fastening & straps per plan, dining room & master bed -three continuous full height king studs at rear 2x6 wall left of living room windows -Fireblock all through floor Penetrations -Nail joist hangers above entry (2) -Complete bath exhaust duct installation -three 2x12 at master bed box ceiling per plan -tie walls at master bed/bath -midpoint strap for vertical 2” and smaller DWV -12” oc fastening, stud to stud and abutting studs at all intersecting braced walls -Provide collar ties at ridges -Provide end Support of Valley and hip rafters -Opposing rafters may not offset more than 1 inch at Ridge connection -three 2x4 under beam above loft -Two load bearing jack studs under header per plan, bedroom five entry to bathroom -Two load bearing jack studs under header, bedroom 4/5 bathroom pocket door -Install snow block, bedroom five -Identify white insulated conductors to be used as current carrying conductors at both points of termination -Pressure test gas piping minimum 10 psi for 15 minutes -Support 2x4s laid flat in soffits exceeding 4 feet in length to floor joists above -Address missing stud packs in exterior basement walls per plan -Provide full depth solid blocking over all beams and cantilevers -Full depth solid blocking under kitchen island per plan -three 2x10 foundation to beam for garage floor cantilever & stringer attachment -Address column to beam attachment, under basement stairs -Minimum 12” field 6” edge exterior sheathing fastening per plan throughout -complete plumbing & electrical
Electrical Service Inspection Passed 05/24/2021
Gas Service Inspection - Residential Failed 05/24/2021
Misc
Corrective Action Required
04/06/2021
Pressure test gas piping minimum 10 psi for 15 minutes
Rough Framing Inspection - Residential Passed 6/9/2021 6/9/2021 06/09/2021
All Rough Inspection - Residential Passed 6/9/2021 6/9/2021 06/09/2021
Misc
Resolved
06/09/2021
-deck not ready for inspection -Rafter bearing per plan throughout -Rafter to joist connection per plan throughout -Tighten anchor bolts throughout -Top plate spices to offset minimum 24 inches -Fireblock vertical to horizontal at furr out in garage -Fireblock vertical to horizontal at all soffit to wall connections -Furr out return pan in garage ceiling for insulation -Provide joist hangers at floor joist connection to LVL above utility -Provide minimum 16g galvanized metal ties 1.5” wide at over bored top plates of load bearing walls. Fasten ties across and to the plate at each side of the opening with minimum 4-10dx1.5” at each side of straps. The metal tie must extend a minimum of 6” past the opening. See figure R602.6.1 -Braced wall method CS-PF fastening & straps per plan, dining room & master bed -three continuous full height king studs at rear 2x6 wall left of living room windows -Fireblock all through floor Penetrations -Nail joist hangers above entry (2) -Complete bath exhaust duct installation -three 2x12 at master bed box ceiling per plan -tie walls at master bed/bath -midpoint strap for vertical 2” and smaller DWV -12” oc fastening, stud to stud and abutting studs at all intersecting braced walls -Provide collar ties at ridges -Provide end Support of Valley and hip rafters -Opposing rafters may not offset more than 1 inch at Ridge connection -three 2x4 under beam above loft -Two load bearing jack studs under header per plan, bedroom five entry to bathroom -Two load bearing jack studs under header, bedroom 4/5 bathroom pocket door -Install snow block, bedroom five -Identify white insulated conductors to be used as current carrying conductors at both points of termination -Pressure test gas piping minimum 10 psi for 15 minutes -Support 2x4s laid flat in soffits exceeding 4 feet in length to floor joists above -Address missing stud packs in exterior basement walls per plan -Provide full depth solid blocking over all beams and cantilevers -Full depth solid blocking under kitchen island per plan -three 2x10 foundation to beam for garage floor cantilever & stringer attachment -Address column to beam attachment, under basement stairs -Minimum 12” field 6” edge exterior sheathing fastening per plan throughout -complete plumbing & electrical
Gas Service Inspection - Residential Passed 6/9/2021 6/9/2021 06/09/2021
Misc
Corrective Action Required
05/24/2021
Pressure test gas piping minimum 10 psi for 15 minutes
Driveway Inspection Partial 7/12/2021 7/12/2021 07/12/2021
Misc
Informational
07/12/2021
7/12/21 14:00 depth is correct, rock has been placed and crew is carrying percent of fail for the ada through the sidewalk.
Sidewalk Inspection Partial 7/12/2021 7/12/2021 07/12/2021
Misc
Informational
07/12/2021
7/12/21 14:00 correct depth of rock, sidewalk is 5 ft off the back of curb and crew is carrying the correct % throughout.
Driveway Inspection Passed 7/15/2021 7/15/2021 07/15/2021
Misc
Informational
07/12/2021
7/12/21 14:00 depth is correct, rock has been placed and crew is carrying percent of fail for the ada through the sidewalk.
Misc
Informational
07/15/2021
7/15/21 7:40- Drive and curb are correct. Drive is carrying a 1.5% through the sidewalk.
Sidewalk Inspection Passed 7/15/2021 7/15/2021 07/15/2021
Misc
Informational
07/12/2021
7/12/21 14:00 correct depth of rock, sidewalk is 5 ft off the back of curb and crew is carrying the correct % throughout.
Misc
Informational
07/15/2021
7/15/21 7:45- Sidewalk is carrying 1.5% slope throughout and has been white cured.
Occupancy Inspection - Codes Residential Not Ready 9/29/2021 9/29/2021 09/29/2021
Miscellaneous Correction
Corrective Action Required
09/29/2021
*NOT READY -No erosion control in place, no address
Erosion Control Inspection Residential Passed 09/30/2021
Misc
Resolved
09/30/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -Immediate street cleanup required -No further inspections until issues are resolved
Occupancy Inspection - Codes Residential Not Ready 9/30/2021 9/30/2021 09/30/2021
Miscellaneous Correction
Corrective Action Required
09/29/2021
*NOT READY -No erosion control in place, no address **9/30 NOT-READY FEE ASSESSED. PAINTER STILL INSIDE PAINTING CABINET DOORS IN THE GARAGE, PEOPLE DOING PAINT TOUCH-UP INSIDE THE HOUSE, STUFFS LAYING AGAINST THE GARAGE WALL, ETC.
Occupancy Inspection - Codes Residential Failed 10/4/2021 10/4/2021 10/04/2021
Miscellaneous Correction
Corrective Action Required
09/30/2021
-Pay all fees due before final occupancy -Final grade and sod -Provide gutters, downspouts and sump discharge extension -Label non GFCI outlets in garage -Complete plumbing fixtures -Secure water service line -Provide (2) 3" screws per hinge at front and basement doors -Provide angle bracket at end joist to ledger connection -Have engineer provide guidance on post to beam connections at deck not code compliant
Occupancy Inspection - Codes Residential Temporary C of O 10/6/2021 10/6/2021 10/06/2021
Miscellaneous Correction
Corrective Action Required
10/04/2021
TCO until 11/03/2021 -clean and add erosion control at sidewalk until sod is in place -Final grade and sod -Provide gutters, downspouts and sump discharge extension -Provide angle bracket at end joist to ledger connection -Have engineer provide guidance on post to beam connections at deck not code compliant
Plot Plan Inspection Passed 3/1/2022 03/01/2022
Occupancy Inspection - Codes Residential Full C of O 4/11/2022 4/11/2022 04/11/2022
Miscellaneous Correction
Resolved
04/11/2022
TCO until 11/03/2021 -clean and add erosion control at sidewalk until sod is in place -Final grade and sod -Provide gutters, downspouts and sump discharge extension -Provide angle bracket at end joist to ledger connection -Have engineer provide guidance on post to beam connections at deck not code compliant
Documents & Images
Date Uploaded File Type Document Name
10/30/2020 20-090 Lot 3 Whispering Woods (Brooklyn) - S&S
10/30/2020 revised signed copy address change lot 3
10/30/2020 WHISPERING WOODS LOT 3 APPLICATION
11/04/2020 Plans APPROVED HOUSE PLAN
11/04/2020 Plot Plan APPROVED PLOT PLAN
11/04/2020 Receipt Receipt for transaction:2020-007382
11/04/2020 Letter DS Building Permit
12/28/2020 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/15/2021 1920 SW River Run Dr_PIER INSP_2020-12-23
01/15/2021 Plans APPROVED HOUSE PLAN SHEET
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
03/10/2021 Letter INSPECTION SUMMARY
03/10/2021 Letter INSPECTION SUMMARY
03/17/2021 Letter INSPECTION SUMMARY
03/30/2021 Approved Plans Approved Revised Drawings
04/05/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter INSPECTION SUMMARY
04/06/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
05/12/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/12/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
09/29/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
09/30/2021 Letter INSPECTION SUMMARY
10/04/2021 Letter INSPECTION SUMMARY
10/05/2021 Receipt Receipt for transaction:2021-007790
10/06/2021 Letter Codes Temporary Certificate of Occupancy
02/23/2022 Letter Codes 140 Day Letter
02/28/2022 Plot Plan Approved As Graded Plot Plan
03/01/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter Codes Final Certificate of Occupancy
04/11/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home