Summary
PRRES20203793
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO SUSPENDED SLAB
10/16/2020
01/14/2021
04/24/2021
12/27/2022
Locations
Contacts
TRUMARK HOMES, LLC, Address:424 SE MAXWELL DR, Phone:(816) 564-5613  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
YANCIK@SBCGLOBAL.NET  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/16/2020 11/12/2020
Kim Brennan
Residential Plan Review Approved 11/16/2020 11/12/2020
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
11/12/2020

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) Not shown for bedroom #2
Plot Plan Review Approved 10/28/2020 10/26/2020
Kim Brennan
Deck location
Corrective Action Required
10/26/2020

Deck/patio location, with dimensions to property lines must be provided on the plot plan.
Basement elevation
Corrective Action Required
10/26/2020

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.)
Residential Plan Review Rejected 10/28/2020 10/26/2020
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
10/26/2020

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) Not shown for bedroom #2
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,142.61 $1,142.61 Paid 01/13/2021
Right of Way Permit Fee $80.00 $80.00 Paid 01/13/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/13/2021
8331507-Sewer Connection Fee $630.00 $630.00 Paid 01/13/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 01/13/2021
Water Meter Fee $455.54 $455.54 Paid 01/13/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 08/11/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 03/17/2021
Underslab Plumbing Inspection - Residential Passed 4/7/2021 4/7/2021 04/07/2021
Sewer Service Inspection - R Not Ready 4/21/2021 (9:30) 4/21/2021 04/21/2021
Misc
Informational
04/21/2021
Plumber originally scheduled a ready time of 8:30am, inspector was onsite at 8:40 and the job wasn’t complete as the plumber had to leave the job site and collect needed parts. Plumber rescheduled inspection for 9:30, inspector onsite at 9:35 and job is still not ready for inspection, therefore a not ready fee has been assessed. Plumber to reschedule when work is complete and ready for inspection.
Water Service Inspection - R Passed 4/21/2021 (1:00) 4/21/2021 04/21/2021
Sewer Service Inspection - R Passed 4/21/2021 (1:00) 4/21/2021 04/21/2021
Misc
Resolved
04/21/2021
Plumber originally scheduled a ready time of 8:30am, inspector was onsite at 8:40 and the job wasn’t complete as the plumber had to leave the job site and collect needed parts. Plumber rescheduled inspection for 9:30, inspector onsite at 9:35 and job is still not ready for inspection, therefore a not ready fee has been assessed. Plumber to reschedule when work is complete and ready for inspection.
Erosion Control Inspection Residential Failed 05/13/2021
Misc
Corrective Action Required
05/13/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Piers/Caissons Inspection - Residential Passed 6/23/2021 06/23/2021
All Rough Inspection - Residential Failed 7/29/2021 07/29/2021
Misc
Corrective Action Required
07/29/2021
Failed- eyebrow over nail patter and nail patter on the sides is not 3" o.c. remove and recall
Erosion Control Inspection Residential Failed 7/29/2021 07/29/2021
Misc
Corrective Action Required
05/13/2021
-Erosion control requires continuous maintenance. -no further inspections until issues are resolved repair erosion control and over grown vegitation.
Electrical Service Inspection Passed 9/22/2021 9/22/2021 09/22/2021
All Rough Inspection - Residential Failed 9/22/2021 9/22/2021 09/22/2021
Misc
Corrective Action Required
07/29/2021
-Nail blue sheathing at front -Garage PFH wall seams shall be within 24” of mid-wall height, blocked, and nailed; install 2”x2” washers; support end of header; nail sheathing to header 3” grid pattern -Protect plumbing at laundry, garage side -Install stud shoes at over-bored laundry wall roof-support double studs. -Fb wall from roof adjacent to pantry door Install collar tie near ridge -Nail corner studs per code. Check all -Protect plumbing at stair/bathroom wall with BOCA plate -Support csst gas line every 32” or less -Solid block under great room I beam point load and trimmer stud point load -Fb wall from I beam soffit at front basement bedroom closet; fb rear bedroom wall from soffit -Seal penetrations of wall and ceiling return air space -S trap above basement bathroom toilet not allowed -Complete supply ducting inside soffit above wet bar -Gas line cannot be inside return air space -Toe nail all joists to sill plates per code -Submit engineer letter for ridge I beam in place of triple 24” lvl beam **DO NOT INSULATE
Gas Service Inspection - Residential Failed 9/22/2021 9/22/2021 09/22/2021
Misc
Corrective Action Required
09/22/2021
-Reroute gas line out of return air space and retest
Misc
Corrective Action Required
09/22/2021
-Reroute gas line out of return air space and retest
All Rough Inspection - Residential Failed 10/5/2021 10/05/2021
Misc
Corrective Action Required
09/22/2021
-Garage PFH-support end of header -Install stud shoes at over-bored laundry wall roof-support -double Stud -S trap above basement bathroom toilet not allowed-Complete pex, connect bath exhaust, Fb floor penetration -Submit engineer letter for ridge I beam in place of triple 24” lvl beam **DO NOT INSULATE
Gas Service Inspection - Residential Passed 10/5/2021 10/05/2021
Misc
Resolved
10/05/2021
-Reroute gas line out of return air space and retest
Misc
Resolved
10/05/2021
-Reroute gas line out of return air space and retest
All Rough Inspection - Residential Failed 10/11/2021 10/11/2021 10/11/2021
Misc
Corrective Action Required
10/05/2021
-Submit engineer letter for ridge I beam in place of triple 24” lvl beam ** Ok TO INSULATE
Driveway Inspection Partial 11/29/2021 11/29/2021 11/29/2021
Misc
Informational
11/29/2021
Driveway was framed up with aggregate in and compacted. 11/29 ES
Driveway Inspection Passed 12/3/2021 12/3/2021 12/03/2021
Misc
Informational
11/29/2021
Driveway was framed up with aggregate in and compacted. 11/29 ES
Misc
Informational
12/03/2021
Finished driveway meets LS and ADA specs. RP 12-3-21
Sidewalk Inspection Partial 12/10/2021 12/10/2021 12/10/2021
Misc
Informational
12/10/2021
Forms were placed and aggregate was present and compacted. RP 12-10-21
Sidewalk Inspection Passed 12/17/2021 12/17/2021 12/17/2021
Misc
Informational
12/10/2021
Forms were placed and aggregate was present and compacted. RP 12-10-21
Misc
Informational
12/17/2021
Sidewalk meets LS and Ada spec. 12/17/21 ES
All Rough Inspection - Residential Passed 02/16/2022
Misc
Resolved
02/16/2022
Occupancy Inspection - Codes Residential Failed 2/16/2022 2/16/2022 02/16/2022
Miscellaneous Correction
Corrective Action Required
02/16/2022
- final grading and sod - Splash blocks - Back flow device in basement - Obtain irrigation permit - Obtain back flow certification - Address in contrasting colors - Dust covering on smoke detectors - Install tub master - Repair hole in sheet rock master bathroom - Install lock and secondary lock on sliding door - Water hammer device for laundry, in wall? Or missing - Provide steps for Egress windows - Label non GFCI OUTLETS - remove gauge from gas line - Add strap to ductwork basement from I beam to exterior wall - Attach AC whip - Seal top of meter can and AC disconnect -
Erosion Control Inspection Residential Passed 2/16/2022 02/16/2022
Misc
Corrective Action Required
07/29/2021
-Erosion control requires continuous maintenance. -no further inspections until issues are resolved repair erosion control and over grown vegitation.
Occupancy Inspection - Codes Residential Temporary C of O 4/14/2022 4/14/2022 04/14/2022
Miscellaneous Correction
Corrective Action Required
02/16/2022
- final grading and sod - Splash blocks TCO expires 5/13/22
Occupancy Inspection - Codes Residential Failed 7/22/2022 7/22/2022 07/22/2022
Miscellaneous Correction
Corrective Action Required
04/14/2022
- final grading and sod - Splash blocks not complete Shawn Hoffman 07/22/2022 10:11 AM TCO expires 5/13/22 - expired TCO must fill out extention form, and submit -pay TCO fee
Plot Plan Inspection Passed 12/27/2022
Misc
Informational
12/27/2022
- BACK YARD INCOMPLETE, HOME OWNER INSTALLING INGROUND POOL ON DIFFERENT PERMIT.
Occupancy Inspection - Codes Residential Full C of O 12/27/2022 12/27/2022 12/27/2022
Documents & Images
Date Uploaded File Type Document Name
10/16/2020 Application Form Permit Application and license tax form
10/21/2020 WINTERSET STAMPED PLANS LOT 1437
10/26/2020 Letter Codes Residential Plan Review
10/26/2020 Plot Plan Approved Plot Plan
11/12/2020 Approved Plans Approved Drawings
01/13/2021 Receipt Receipt for transaction:2021-000204
01/14/2021 Letter DS Building Permit
03/16/2021 Garys Fndn 157 NW Carson Dr Lee's Summit Mo 3rd Party Footing Inspection Report 3-15-21
03/17/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter INSPECTION SUMMARY
06/23/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
08/11/2021 Receipt Receipt for transaction:2021-006471
09/22/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter INSPECTION SUMMARY
10/11/2021 Letter INSPECTION SUMMARY
10/11/2021 157 NW Carson Dr LSMO Substitute Stl Bm for LVL 10-7-21
11/29/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter INSPECTION SUMMARY
12/17/2021 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
02/16/2022 Letter INSPECTION SUMMARY
03/11/2022 SKM_C36822031109541
04/14/2022 Letter Codes Temporary Certificate of Occupancy
04/14/2022 Letter Codes Temporary Certificate of Occupancy
07/22/2022 Letter INSPECTION SUMMARY
12/09/2022 Letter Codes 140 Day Letter
12/27/2022 Letter INSPECTION SUMMARY
12/27/2022 Letter Field Certificate of Occupancy
12/27/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: