Permit Application Status

PRRES20202889


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202889
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
09/09/2020
09/09/2020
06/04/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 09/11/2020 09/09/2020
Shannon McGuire
Plot Plan Review Approved 09/11/2020 09/09/2020
Kim Brennan
Residential Plan Review Approved 09/11/2020 09/09/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,283.19 $1,283.19 Paid 09/09/2020
Right of Way Permit Fee $80.00 $80.00 Paid 09/09/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/09/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 09/09/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 09/09/2020
Water Meter Fee $455.54 $455.54 Paid 09/09/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/8/2020 10/8/2020 10/08/2020
Underslab Plumbing Inspection - Residential Failed 11/4/2020 11/4/2020 11/04/2020
Misc
Corrective Action Required
11/04/2020
- SLEEVE HOT AND COLD PEX FOR PROTECTION AT SLAB EXIT
Sewer Service Inspection - R Passed 1/22/2021 (8:00) 1/22/2021 01/22/2021
Water Service Inspection - R Partial 01/22/2021
Misc
Informational
01/22/2021
Partial approval from structure to metallic connection customer side of meter
Electrical Service Inspection Passed 1/27/2021 1/27/2021 01/27/2021
Gas Piping Inspection - Residential Passed 1/27/2021 1/27/2021 01/27/2021
Gas Service Inspection - Residential Failed 1/27/2021 1/27/2021 01/27/2021
Misc
Corrective Action Required
01/27/2021
-GAS PRESSURE AT 5 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 1/27/2021 1/27/2021 01/27/2021
Misc
Corrective Action Required
01/27/2021
-Maintain silt fence at front of lot, correct issues before rescheduling inspection -Fireblock vertical to horizontal at furred down in garage, seal gaps -Fur down at HVAC duct in garage ceiling for insulation in unconditioned space -Secure all vertical DWV 2” or less at mid point -structural straps required at all top plate penetrations 50% or more, all exterior walls and all interior load bearing walls - (4) nails required at each side of plate -Bocca protection plates required at all piping within 1 1/4” of edge of member, plates shall have a thickness of not less than (No. 16 gage). Such plates shall cover the area of the pipe where the member is notched or bored, and shall extend not less than 2 inches (51 mm) above sole plates and below top plates. IPC 305.6 -H2.5 truss straps required at hip truss and truss at 1st floor shower -Correct size stud shoes for single stud at laundry, 1st floor bath -H2.5 straps at dbl truss girder at living room windows -security blocking at exterior doors -LIB bracing all locations per plans -(2) 1 3/4” x 9 1/4” lvl header at flex room slider per plans -H2.5 truss clips at bed#4 closet -snow block bed #4 closet -Truss hangers per plans 1st floor -Truss bracing per plans -Joist hanger required at E side basement connection to header, over 4’ -Anchor all columns to floor in basement -basement, W8x24 steel beam supported at wall by (5) 2x6 and 3” SCH columns at piers “A” and “B” per plans -(3) 1 3/4” x 9 1/4” lvl, S side basement, bearing on (4) 2x6 per plans -6”x6” cedar post full height at covered deck per plans -(2) bolts at each post/beam connection per code at deck -bolt outer rim to ledger and add angel clips to inner ply at deck
Erosion Control Inspection Residential Failed 1/27/2021 1/27/2021 01/27/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/27/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Water Service Inspection - R Passed 1/28/2021 (1:00) 1/28/2021 01/28/2021
Misc
Informational
01/22/2021
Partial approval from structure to metallic connection customer side of meter
All Rough Inspection - Residential Failed 2/1/2021 2/1/2021 02/01/2021
Misc
Corrective Action Required
01/27/2021
-Fireblock vertical to horizontal at furred down in garage (seal gaps) -Secure all vertical DWV 2” or less at mid point -structural straps required at all top plate penetrations 50% or more, all exterior walls and all interior load bearing walls - (4) nails required at each side of plate -Bocca protection plates required at all piping within 1 1/4” of edge of member, plates shall have a thickness of not less than (No. 16 gage). Such plates shall cover the area of the pipe where the member is notched or bored, and shall extend not less than 2 inches (51 mm) above sole plates and below top plates. IPC 305.6 -H2.5 truss straps required at hip truss and truss at 1st floor shower -Correct size stud shoes for single stud at 1st floor bath #1 bearing wall -H2.5 straps at dbl truss girder at living room windows and 2nd floor truss end -security blocking at exterior doors - deck door -LIB bracing all locations per plans -2nd floor -Truss hangers per plans 1st floor -J22 -basement, W8x24 steel beam supported at wall by (5) 2x6 per plans -6”x6” cedar post full height at covered deck per plans -(2) bolts at each post/beam connection per code at deck -bolt outer rim to ledger and add angel clips to inner ply at deck
Gas Service Inspection - Residential Failed 2/1/2021 2/1/2021 02/01/2021
Misc
Corrective Action Required
01/27/2021
-GAS PRESSURE AT 3 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Passed 2/2/2021 2/2/2021 02/02/2021
Misc
Resolved
02/02/2021
Gas Service Inspection - Residential Passed 2/2/2021 2/2/2021 02/02/2021
Misc
Resolved
02/02/2021
Sidewalk Inspection Partial 3/26/2021 3/26/2021 03/26/2021
Misc
Informational
03/26/2021
3-26-21 1:29pm The forms are set and the aggregate is compacted. It is ADA compliant at this time.
Driveway Inspection Partial 3/26/2021 3/26/2021 03/26/2021
Misc
Informational
03/26/2021
3-26-21 1:31pm The forms are set and the aggregate is compacted. They are pouring new curb at the driveway.
Sidewalk Inspection Passed 3/30/2021 3/30/2021 03/30/2021
Misc
Informational
03/26/2021
3-26-21 1:29pm The forms are set and the aggregate is compacted. It is ADA compliant at this time.
Driveway Inspection Passed 3/30/2021 3/30/2021 03/30/2021
Misc
Informational
03/26/2021
3-26-21 1:31pm The forms are set and the aggregate is compacted. They are pouring new curb at the driveway.
Underslab Plumbing Inspection - Residential Passed 11/5/2020 04/07/2021
Misc
Resolved
04/07/2021
Occupancy Inspection - Codes Residential Failed 4/7/2021 4/7/2021 04/07/2021
Misc
Corrective Action Required
04/07/2021
-Final grade and sod -Guardrail at front porch, more than 30” from grade -splash blocks at all downspout and sump pump locations, minimum 36” discharge from foundation -Seal all penetrations in siding, seal along top of AC disconnect and meter can -Cover plates at all switches and receptacles -Install faucet at kitchen sink -Install non combustible attic access cover bedroom closet 2nd floor -Security screws at basement walkout, (2) 3” screws at strike plate and each hinge -Breaker lockout at cooktop circuit -Identify dedicated receptacles at garage and unfinished basement as not GFCI protected
Occupancy Inspection - Codes Residential Temporary C of O 4/12/2021 4/12/2021 04/12/2021
Misc
Corrective Action Required
04/07/2021
-Final grade and sod -splash blocks at all downspout and sump pump locations, minimum 36” discharge from foundation OK FOR TCO - TCO EXPIRES 4/26/21
Occupancy Inspection - Codes Residential Temporary C of O 4/28/2021 4/28/2021 04/28/2021
Misc
Corrective Action Required
04/12/2021
-Final grade and sod -splash blocks at all downspout and sump pump locations, minimum 36” discharge from foundation OK FOR TCO - TCO EXTENSION - TCO EXPIRES 5/6/21
Occupancy Inspection - Codes Residential Temporary C of O 5/6/2021 5/6/2021 05/06/2021
Misc
Corrective Action Required
04/28/2021
-Sod less than 6" from siding - see south side and rear west side of house OK FOR TCO - TCO EXTENSION - TCO EXPIRES 5/20/21
Plot Plan Inspection Passed 06/04/2021
Erosion Control Inspection Residential Passed 06/04/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/04/2021
Occupancy Inspection - Codes Residential Full C of O 6/4/2021 6/4/2021 06/04/2021
Misc
Resolved
06/04/2021
Documents & Images
Date Uploaded File Type Document Name
09/09/2020 Application Form Permit Application and license tax form
09/09/2020 Approved Plans Approved Truss Layout
09/09/2020 Approved Plans Approved Truss Package
09/09/2020 Plot Plan Approved Plot Plan
09/09/2020 Approved Plans Approved Drawings
09/09/2020 Receipt Receipt for transaction:2020-006083
09/09/2020 Letter DS Building Permit
10/07/2020 Lot 21 Hawthorne Ridge Footing
10/08/2020 Letter INSPECTION SUMMARY
10/19/2020 Lot 21 Hawthorne Ridge Wall Inspection
11/04/2020 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
02/01/2021 Letter INSPECTION SUMMARY
02/01/2021 Letter INSPECTION SUMMARY
02/02/2021 Letter INSPECTION SUMMARY
02/02/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/12/2021 Letter Codes Temporary Certificate of Occupancy
04/28/2021 Email RE 3100 SW arboridge TCO
04/28/2021 Letter Codes Temporary Certificate of Occupancy
05/06/2021 Letter Codes Temporary Certificate of Occupancy
06/04/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter INSPECTION SUMMARY
06/04/2021 Letter Field Certificate of Occupancy
06/04/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home