Permit Application Status

PRRES20202689


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202689
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - UNFINISHED BASEMENT
09/01/2020
09/23/2020
01/05/2022
Locations
Contacts
ASPEN HOME BUILDERS LLC, Address:6618 ROYAL ST #B, Phone:(816) 507-0123  
STEVE@ASPENHOMESKC.COM  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/03/2020 09/18/2020
Dylan Eppert
Basement egress
Corrective Action Required
09/03/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. HOUSE PLANS SHOW EGRESS WELL PLEASE CONFIRM LOCATION WITH BUILDER AND HAVE IT WITH LAG.
As-graded plot plan
Corrective Action Required
09/03/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 09/03/2020 09/18/2020
Dylan Eppert
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
09/03/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) ADD ANOTHER COMBO DETECTOR UPSTAIRS AS CODE STATES THAT A COMBO DETECTOR SHOULD BE DIRECTLY OUTSIDE A MAX OF 10' AWAY.
07 Identify emergency escape openings from bedrooms
Corrective Action Required
09/03/2020

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) EGRESS WINDOW IN BEDROOM 4 IS NOT LABELED.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,241.64 $1,241.64 Paid 09/23/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 09/23/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 09/23/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 09/23/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/23/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/23/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/14/2020 (8:15) 10/14/2020 10/14/2020
Misc
Informational
10/14/2020
Please provide site addresses for projects on SW River Trail, SW Old Port Rd & SW Hickory Ln
Erosion Control Inspection Residential Passed 10/21/2020
Misc
Resolved
10/21/2020
Provide erosion control at East and south property lines
Underslab Plumbing Inspection - Residential Passed 11/24/2020 11/24/2020 11/24/2020
Sewer Service Inspection - R Passed 1/19/2021 (1:00) 1/19/2021 01/19/2021
Erosion Control Inspection Residential Failed 01/20/2021
Misc
Corrective Action Required
10/14/2020
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -no further inspections until issues are resolved
Water Service Inspection - R Passed 1/22/2021 (1:00) 1/22/2021 01/22/2021
Erosion Control Inspection Residential Passed 02/04/2021
Misc
Resolved
02/04/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -no further inspections until issues are resolved
All Rough Inspection - Residential Partial 4/1/2021 4/1/2021 04/01/2021
Misc
Informational
04/01/2021
Portal frame approved
Electrical Service Inspection Passed 7/20/2021 7/20/2021 07/20/2021
Gas Service Inspection - Residential Failed 7/20/2021 7/20/2021 07/20/2021
Misc
Corrective Action Required
07/20/2021
-Bond gas line before ward flex connections -pressure test ok
All Rough Inspection - Residential Failed 7/20/2021 7/20/2021 07/20/2021
Misc
Informational
04/01/2021
Portal frame approved
Miscellaneous Correction
Corrective Action Required
07/20/2021
-Maintain erosion control at perimeter of lot -Sister over notched studs in garage -Tighten all anchor bolts -Anchor bolts to be in middle third of plate -Seal all plate penetrations -Strap load bearing walls bored greater than 50% throughout -Nail stud shoes throughout -Fireblock top of cabinet space at fridge -Midpoint strap all 2” and smaller dwv -Clarify full height studs at front wall not framed full height -Add studs at load bearing closet wall for roof support -Fire block tub traps -Nail joist to rafter connections per code throughout -Identify ufer ground all locations -Identify white insulated conductors used as current carrying conductors at bot ends -Bond gas line before ward flex connection -Provide ledger to house connections and (2) 1/2" through bolts at post to beam connection at deck
All Rough Inspection - Residential Failed 7/27/2021 7/27/2021 07/27/2021
Misc
Informational
07/20/2021
Portal frame approved
Miscellaneous Correction
Corrective Action Required
07/20/2021
OK to insulate -Strap load bearing walls bored greater than 50% throughout-both sides of interior walls -Fireblock top of cabinet space at fridge-seal gaps and at dwv -Midpoint strap all 2” and smaller dwv -Identify ufer ground and gas bond at all locations -Bond gas line before ward flex connection-before range -Provide ledger to house connections and (2) 1/2" through bolts at post to beam connection at deck
Gas Service Inspection - Residential Failed 7/27/2021 7/27/2021 07/27/2021
Misc
Corrective Action Required
07/20/2021
-Bond gas line before ward flex connections-before range -pressure test ok
All Rough Inspection - Residential Failed 7/30/2021 7/30/2021 07/30/2021
Misc
Resolved
07/28/2021
Portal frame approved
Miscellaneous Correction
Corrective Action Required
07/27/2021
OK to insulate -Identify ufer ground and gas bond at all locations-BOTH ends -Bond gas line before ward flex connection-before range-Terminate in panel and identify as grounding conductor on each end -Provide ledger to house connections and (2) 1/2" through bolts at post to beam connection at deck
Gas Service Inspection - Residential Failed 7/30/2021 7/30/2021 07/30/2021
Misc
Corrective Action Required
07/27/2021
-Bond gas line before ward flex connections-before rang Terminate in panel and identify as grounding conductor on each end -pressure test ok
All Rough Inspection - Residential Failed 8/3/2021 8/3/2021 08/03/2021
Miscellaneous Correction
Corrective Action Required
07/30/2021
OK to rock -Provide ledger to house connections and (2) 1/2" through bolts at post to beam connection at deck
Gas Service Inspection - Residential Passed 8/3/2021 8/3/2021 08/03/2021
Misc
Resolved
08/03/2021
-Bond gas line before ward flex connections-before rang Terminate in panel and identify as grounding conductor on each end -pressure test ok
Piers/Caissons Inspection - Residential Passed 8/19/2021 08/19/2021
Driveway Inspection Passed 10/21/2021 10/21/2021 10/21/2021
Misc
Informational
10/21/2021
On 10/21/2021 I performed a driveway inspection and pass the subgrade to pour concrete. DJ
Plot Plan Inspection Passed 11/15/2021 11/15/2021
Misc
Informational
11/15/2021
All Rough Inspection - Residential Passed 11/30/2021 11/30/2021
Miscellaneous Correction
Corrective Action Required
08/03/2021
OK to rock -Provide ledger to house connections and (2) 1/2" through bolts at post to beam connection at deck
Occupancy Inspection - Codes Residential Failed 11/30/2021 11/30/2021 11/30/2021
Misc
Corrective Action Required
11/30/2021
- adjust steps in garage to meet code Address handrail in garage -Provide ledger to house connections
Occupancy Inspection - Codes Residential Temporary C of O 12/1/2021 12/1/2021 12/01/2021
Misc
Corrective Action Required
11/30/2021
- final grading and sod
Piers/Caissons Inspection - Residential Passed 01/05/2022
Occupancy Inspection - Codes Residential Full C of O 1/5/2022 1/5/2022 01/05/2022
Misc
Corrective Action Required
12/01/2021
- final grading and sod
Documents & Images
Date Uploaded File Type Document Name
09/01/2020 Application Form Lot 743 app
09/01/2020 Chestnut lot 743 plot plan
09/01/2020 Lot 743 EC Chestnut
09/03/2020 Letter Codes Residential Plan Review
09/10/2020 Engineer Report/Study ENGINEER REPORT
09/18/2020 Lot 743 EC Chestnut REVISED
09/18/2020 Lot 743 plot plan REVISED
09/18/2020 Plans APPROVED HOUSE PLAN
09/18/2020 Plot Plan APPROVED PLOT PLAN
09/23/2020 Receipt Receipt for transaction:2020-006420
09/23/2020 Letter DS Building Permit
10/14/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/21/2020 Letter INSPECTION SUMMARY
10/21/2020 Letter INSPECTION SUMMARY
11/24/2020 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
07/20/2021 Letter INSPECTION SUMMARY
07/20/2021 Letter INSPECTION SUMMARY
07/20/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
07/27/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
07/30/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
11/12/2021 Plot Plan Approved As Graded Plot Plan
11/15/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter INSPECTION SUMMARY
12/01/2021 Letter Codes Temporary Certificate of Occupancy
01/05/2022 Letter Codes Final Certificate of Occupancy
01/05/2022 Letter Field Certificate of Occupancy
01/13/2022 Letter INSPECTION SUMMARY
02/23/2024 M L Crose 2345 SW Hickory Lane LSMO Eagle Creek Lot 743 Aspen Permit 2020-2689 3rd Party Footing Inspection Report 2-21-24
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home