Summary
PRRES20202688
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
09/01/2020
09/23/2020
12/08/2021
Locations
Contacts
ASPEN HOME BUILDERS LLC, Address:6618 ROYAL ST #B, Phone:(816) 507-0123  
STEVE@ASPENHOMESKC.COM  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 09/03/2020 09/17/2020
Dylan Eppert
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
09/03/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) APPLICATION AND HOUSE PLANS DO NOT MATCH WHEN IT COMES TO BASEMENT AND THE FINISHED AND UNFINISHED SQ FOOTAGES. THE HOUSE PLANS MUST HAVE FINISHED AND UNFINISHED SQ FOOTAGES.
Miscellaneous Correction
Corrective Action Required
09/03/2020

COVER PAGE REFERENCES THE 2012 IRC BUILDING CODE AND NEED TO REFLECT THE 2018 IRC BUILDING CODE.
Miscellaneous Correction
Corrective Action Required
09/03/2020

PLOT PLAN SHOWS EGRESS WELL AND HOUSE PLANS DO NOT PLEASE CLARIFY AS THE HOUSE PLANS AND PLOT PLAN SHOULD MATCH.
Plot Plan Review Approved 09/03/2020 09/04/2020
Dylan Eppert
Basement egress
Corrective Action Required
09/03/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. PLEASE HAVE HOUSE PLANS AND PLOT PLAN MATCH AS ONE SHOWS AND EGRESS WELL AND ANOTHER SHOWS A WINDOW OUT THE REAR ELEVATION. PLEASE CLARIFY AND REVISE AS NEEDED.
As-graded plot plan
Corrective Action Required
09/03/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,244.54 $1,244.54 Paid 09/23/2020
8331507-Sewer Connection Fee $480.00 $480.00 Paid 09/23/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 09/23/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 09/23/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/23/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 09/23/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/13/2020 (3:30) 10/13/2020 10/13/2020
Erosion Control Inspection Residential Passed 10/21/2020
Misc
Resolved
10/21/2020
Please provide erosion control rear of lot
Underslab Plumbing Inspection - Residential Passed 12/14/2020 12/14/2020
Sewer Service Inspection - R Passed 1/11/2021 01/11/2021
Water Service Inspection - R Passed 1/13/2021 01/13/2021
Erosion Control Inspection Residential Failed 2/3/2021 02/03/2021
Misc
Corrective Action Required
10/13/2020
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -remove debris from curb/gutter -maintain gravel filter -no further inspections until issues are resolved
All Rough Inspection - Residential Failed 3/8/2021 3/8/2021 03/08/2021
Misc
Corrective Action Required
03/08/2021
Provide interior tension straps, OK to cover exterior
Piers/Caissons Inspection - Residential Passed 4/2/2021 04/02/2021
All Rough Inspection - Residential Failed 6/3/2021 6/3/2021 06/03/2021
Misc
Corrective Action Required
03/08/2021
-Minimum 12” field 6” edge exterior sheathing fastening, Ensure fasteners are penetrating framing members -Deck post/beam connections per code -Provide proper connection device at deck Joist to ledger connections -Portal opening interior tension strap to be attached to a full length stud -Fireblock Plate Penetrations throughout, locations marked -Furr out supply and return ducts in Garage ceiling for insulation -Full depth solid blocking between floor joists above garage beam -Joist lap and fastening per code, ceiling joists at Garage beam -Finish nailing stud shoes, use all available nail holes -Penetrations in floor joists shall not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member. Correct or provide engineered solution for repair. Pex penetrations above mudroom, 3 floor joists. Pex penetrations above pantry 1 floor joist. Pex penetrations above great room 4 floor joists. Pex penetrations above kitchen, 1 floor joist. -Fireblock vertical to horizontal at soffit to wall connection, garage/bathroom wall -Complete bath exhaust duct installation -Provide nail plate protection at Conductor stud/plate Penetrations, locations marked -Plumbing nail plate protection to extend minimum 2 inches below top plate, pex at pantry top plate -Protect NM conductors from physical damage minimum 6” AFF at floor penetrations -Nail headers to King studs per code -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Secure gas piping at fireplace -Provide bearing support of covered front porch beam -Fireblock all through floor Penetrations -Ensure metal strap LIB bracing is properly fastened to studs -full height studs required, strap non-continuous studs -Install snow block, master bath -Properly fastened joist hangers, second floor ceiling joist to LVL beam connection -Top plate spices to offset minimum 24 inches, second-floor bath -Midpoint support for all vertical 2 inches smaller DWV -Adequate fire blocking material second floor Chase, vertical to horizontal -Fireblock vertical to horizontal bedroom to gable wall -Identify white insulated conductors to be used as current carrying conductors at both points of termination -Fireblock vertical to horizontal at soffit to wall connections -Tighten anchor bolts throughout -Address over bored floor joist above basement family room
Electrical Service Inspection Passed 6/3/2021 6/3/2021 06/03/2021
Gas Service Inspection - Residential Passed 6/3/2021 6/3/2021 06/03/2021
All Rough Inspection - Residential Passed 6/25/2021 6/25/2021 06/25/2021
Misc
Resolved
06/25/2021
All corrections made it OK to insulate and rock
Driveway Inspection Partial 8/20/2021 8/20/2021 08/23/2021
Misc
Informational
08/20/2021
On Friday 8/20/2021 I performed a driveway inspection and pass the sub grade to pour concrete
Driveway Inspection Passed 8/27/2021 8/27/2021 08/30/2021
Misc
Informational
08/23/2021
On Friday 8/20/2021 I performed a driveway inspection and pass the sub grade to pour concrete
Misc
Informational
08/30/2021
On Monday 8/30/2021 I inspected the driveway approach after the concrete pour
Piers/Caissons Inspection - Residential Failed 9/16/2021 (11:00) 9/16/2021 09/16/2021
Misc
Corrective Action Required
09/16/2021
(2) 16" x 36" PIERS FOR DECK STAIRS LANDING
Piers/Caissons Inspection - Residential Passed 9/16/2021 9/16/2021 09/16/2021
Misc
Corrective Action Required
09/16/2021
(2) 16" x 36" PIERS FOR DECK STAIRS LANDING
Occupancy Inspection - Codes Residential Failed 10/26/2021 10/26/2021 10/26/2021
Miscellaneous Correction
Corrective Action Required
10/26/2021
- as grade plot plan - final grade, sod and splash blocks -Light fixture missing in upstairs hall bathroom -Set screw in back flow device in basement -Insulation in basement -1/2 “ or equivalent through bolts on deck post for landing
Plot Plan Inspection Failed 10/26/2021 10/26/2021
Miscellaneous Correction
Corrective Action Required
10/26/2021
Needs final grading completed Needs as graded plot plan submitted
Occupancy Inspection - Codes Residential Temporary C of O 10/27/2021 10/27/2021 10/27/2021
Miscellaneous Correction
Corrective Action Required
10/26/2021
- as grade plot plan - final grade, sod and splash blocks
Plot Plan Inspection Passed 11/15/2021 11/15/2021
Miscellaneous Correction
Resolved
11/15/2021
Needs final grading completed Needs as graded plot plan submitted
Occupancy Inspection - Codes Residential Full C of O 12/8/2021 12/8/2021 12/08/2021
Miscellaneous Correction
Resolved
12/08/2021
Documents & Images
Date Uploaded File Type Document Name
09/01/2020 Application Form Lot 733 app
09/01/2020 Birch lot 733 plot plan
09/01/2020 Lot 733 EC Birch
09/03/2020 Letter Codes Residential Plan Review
09/04/2020 Plot Plan APPROVED PLOT PLAN
09/16/2020 Lot 733 Plot plan REVISED
09/16/2020 Birch lot 733 EC REVISED
09/17/2020 Photograph APPROVED HOUSE PLANS
09/17/2020 Plot Plan APPROVED PLOT PLAN
09/23/2020 Receipt Receipt for transaction:2020-006420
09/23/2020 Letter DS Building Permit
10/13/2020 Letter INSPECTION SUMMARY
10/13/2020 Letter INSPECTION SUMMARY
10/21/2020 Letter INSPECTION SUMMARY
10/21/2020 Letter INSPECTION SUMMARY
12/14/2020 Letter INSPECTION SUMMARY
01/11/2021 Letter INSPECTION SUMMARY
01/13/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
03/08/2021 Letter INSPECTION SUMMARY
04/02/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
08/30/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
10/26/2021 Letter INSPECTION SUMMARY
10/26/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter Codes Temporary Certificate of Occupancy
11/12/2021 Plot Plan Approved As Graded Plot Plan
11/15/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter Codes Final Certificate of Occupancy
12/08/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home