Permit Application Status

PRRES20202580


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202580
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
08/26/2020
09/10/2020
02/27/2024
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 346  
TRUMARK HOMES, LLC, Address:424 SE MAXWELL DR, Phone:(816) 564-5613  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
TRUMARKHOMES.MARK@GMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/01/2020 08/31/2020
Kim Brennan
Basement opening elevations
Corrective Action Required
08/31/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
City infrustructure
Corrective Action Required
08/31/2020

Show all manholes, water valve boxes, fire hydrants, and stormwater structures.
Residential Plan Review Approved 09/01/2020 08/28/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,013.28 $1,013.28 Paid 09/10/2020
Right of Way Permit Fee $80.00 $80.00 Paid 09/10/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/10/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 09/10/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 09/10/2020
Water Meter Fee $455.54 $455.54 Paid 09/10/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/28/2020 09/28/2020
Informational
09/28/2020
FOOTING INSPECTED AND APPROVED BY ENGINEER
Underslab Plumbing Inspection - Residential Passed 10/1/2020 10/1/2020 10/01/2020
Rough Framing Inspection - Residential Partial 10/16/2020 10/16/2020
Misc
Corrective Action Required
10/16/2020
GARAGE PORTAL BRACE WALL NAIL OK; HOWEVER, INSTALL STRAPS TO TIE DOWN THE LVL BEAM
Erosion Control Inspection Residential Failed 11/25/2020
Misc
Corrective Action Required
11/25/2020
-Erosion control requires continuous maintenance. Repair damaged sections within 2 business days -street cleanup required -maintain gravel filter No further inspections until complete
All Rough Inspection - Residential Failed 11/25/2020 11/25/2020
Misc
Corrective Action Required
11/25/2020
Inspection denied. No exterior doors or windows & no building address as well as erosion control issues
Gas Service Inspection - Residential Passed 11/30/2020 11/30/2020
Electrical Service Inspection Failed 11/30/2020 11/30/2020
Misc
Corrective Action Required
11/30/2020
- PROVIDE ACCESS TO UFER GROUND WITH APPROVED CLAMP -
Erosion Control Inspection Residential Passed 11/30/2020 11/30/2020 11/30/2020
Misc
Resolved
11/30/2020
-Erosion control requires continuous maintenance. Repair damaged sections within 2 business days -street cleanup required -*** maintain gravel filter ****
All Rough Inspection - Residential Failed 11/30/2020 11/30/2020 11/30/2020
Misc
Corrective Action Required
11/25/2020
Inspection denied. No exterior doors or windows & no building address as well as erosion control issues
Misc
Corrective Action Required
11/30/2020
- PROVIDE ADDRESS - - INSTALL WINDOWS & DOORS - - TIGHTEN ANCHOR BOLTS AT PFH PORTAL FRAMING - - TIGHTEN ANCHOR BOLTS BASEMENT - - SECURE BATH EXHAUST WITH METALLIC TAPE - - PROVIDE MIDPOINT SUPPORT ALL VERTICAL 2" AND SMALLER DWV - - PROVIDE VERTICAL FIRE BLOCK EVERY 10' BED #3 BASEMENT FURR OUT - -PROVIDE INSULATION & BLOCKING AT CANTILEVERS - - STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS ( AT BRACED WALL PANELS) NAIL PER CODE - - ELECTRICAL SERVICE FAILED (UFER ) - NOTE HAMMER ARRESTORS IN WALL AT LAUNDRY ROOM -
Sewer Service Inspection - R Passed 12/2/2020 (8:15) 12/2/2020 12/02/2020
Water Service Inspection - R Failed 12/2/2020 12/02/2020
Misc
Corrective Action Required
12/02/2020
-Provide pipe sleeve 2 sizes greater than the pipe penetrating the foundation wall -Ok to backfill except for area at foundation. Excavated area to be left open should be fenced off. Schedule re-inspection
Water Service Inspection - R Passed 12/7/2020 (8:00) 12/7/2020 12/07/2020
Misc
Resolved
12/07/2020
-Provide pipe sleeve 2 sizes greater than the pipe penetrating the foundation wall -Ok to backfill except for area at foundation. Excavated area to be left open should be fenced off. Schedule re-inspection
Rough Framing Inspection - Residential Passed 12/9/2020 12/9/2020 12/08/2020
Misc
Resolved
12/08/2020
GARAGE PORTAL BRACE WALL NAIL OK; HOWEVER, INSTALL STRAPS TO TIE DOWN THE LVL BEAM
All Rough Inspection - Residential Failed 12/8/2020 12/8/2020 12/08/2020
Misc
Resolved
12/08/2020
Inspection denied. No exterior doors or windows & no building address as well as erosion control issues
Misc
Corrective Action Required
11/30/2020
- INSTALL WINDOWS & DOORS - -PROVIDE INSULATION & BLOCKING AT CANTILEVERS
Electrical Service Inspection Passed 12/8/2020 12/8/2020 12/08/2020
Misc
Resolved
12/08/2020
- PROVIDE ACCESS TO UFER GROUND WITH APPROVED CLAMP -
Driveway Inspection Partial 2/1/2021 (Ready Now) 2/1/2021 02/02/2021
Misc
Informational
02/01/2021
Misc
Informational
02/02/2021
Driveway - forms and materials passed pre-inspection.
Sidewalk Inspection Partial 2/1/2021 (Ready Now) 2/1/2021 02/02/2021
Misc
Informational
02/02/2021
Sidewalk - forms and materials passed pre-inspection.
Sidewalk Inspection Passed 2/4/2021 2/4/2021 02/23/2021
Misc
Informational
02/02/2021
Sidewalk - forms and materials passed pre-inspection.
Misc
Informational
02/23/2021
Sidewalk - passed final inspection.
Driveway Inspection Passed 2/4/2021 2/4/2021 02/23/2021
Misc
Informational
02/02/2021
Misc
Informational
02/02/2021
Driveway - forms and materials passed pre-inspection.
Misc
Informational
02/23/2021
Driveway - passed final inspection.
All Rough Inspection - Residential Passed 04/14/2021
Misc
Resolved
04/14/2021
- INSTALL WINDOWS & DOORS - -PROVIDE INSULATION & BLOCKING AT CANTILEVERS
Occupancy Inspection - Codes Residential Failed 4/14/2021 4/14/2021 04/14/2021
Misc
Corrective Action Required
04/14/2021
Occupancy Inspection - Codes Residential Temporary C of O 4/19/2021 4/19/2021 04/19/2021
Misc
Corrective Action Required
04/14/2021
-Final grade, sod -Screw the basement exterior door embedded brace into studs with 3” screws
Documents & Images
Date Uploaded File Type Document Name
08/26/2020 Application Form Permit Application and license tax form
08/31/2020 Letter Codes Residential Plan Review
08/31/2020 Approved Plans Approved Drawings
08/31/2020 Plot Plan Approved Plot Plan
09/10/2020 Receipt Receipt for transaction:2020-006117
09/10/2020 Letter DS Building Permit
09/26/2020 M L Crose 1316 NE Goshen Dr LSMO Monticello Lot 47 Trumark P 2020-2580 3rd Party Footing Inspection Report 9-23-20
09/28/2020 Letter INSPECTION SUMMARY
10/16/2020 Letter INSPECTION SUMMARY
11/24/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
12/02/2020 Letter INSPECTION SUMMARY
12/02/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter INSPECTION SUMMARY
02/02/2021 Letter INSPECTION SUMMARY
02/02/2021 Letter INSPECTION SUMMARY
02/23/2021 Letter INSPECTION SUMMARY
02/23/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter INSPECTION SUMMARY
04/19/2021 Letter Codes Temporary Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home