Summary
PRRES20201545
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS PACKAGE DEFERRED - ENGINEERED FLOOR SYSTEM DEFERRED - COVERED PATIO - FINISHED BASEMENT
06/09/2020
06/18/2020
12/20/2021
Locations
Contacts
CARDINAL CREST HOMES, Address:1539 SWIFT AVE, Phone:(816) 499-3156  
ADAM@CARDINALCRESTHOMES.COM  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
JOE KILOWATT INC, Address:6506 ROYAL, Phone:(816) 792-4888  
HAMPTON PLUMBING INC, Address:P O BOX 552, Phone:(816) 628-5069  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/11/2020 06/18/2020
Dylan Eppert
Property boundary
Corrective Action Required
06/12/2020

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. PLEASE REVIEW PLAT TO ENURE ALL BEARINGS AND DISTANCES ARE ON THE PLOT PLAN. IT APPEARS YOU ARE MISSING ON. ALSO THE STREET FRONTAGE DISTANCE IS NOT 48' IT SHOULD BE 40.21'
Legal description
Corrective Action Required
06/12/2020

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. PLEASE CONFIRM CORRECT ADDRESS. PLOT PLAN SHOWS 1021 SW ARMIE AND THE HOUSE PLANS SHOW 1033 SW ARMIE ST.
Residential Plan Review Approved 06/11/2020 06/18/2020
Dylan Eppert
Miscellaneous Correction
Corrective Action Required
06/12/2020

PLEASE CONFIRM ADDRESS. PLOT PLAN SHOWS 1021 SW ARMIE AND THE HOUSE PLANS SHOW 1033 SW ARMIE.
02 One (1) complete license tax application
Corrective Action Required
06/12/2020

One (1) complete license tax application
18 Identify type of roof/truss package (if used) complete with layout, comp
Corrective Action Required
06/12/2020

Identify type of roof/truss package (if used) complete with layout, component design, fastening details, blocking and sheathing requirements. (IRC Section 802.10) DEFERRED
31 Identify type of joist package or floor truss package (if used)
Corrective Action Required
06/12/2020

Identify type of joist package or floor truss package (if used) complete with layouts, fastening details, blocking and bracing requirements and minimum sheathing. DEFERRED
30 Identify type of protection used in unfinished areas under
Corrective Action Required
06/12/2020

Identify type of protection used in unfinished areas under floor trusses. (IRC Section R501.3)
Planning Review (RES) Approved 06/16/2020 06/18/2020
Jennifer Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $920.48 $920.48 Paid 06/18/2020
$0.00
Right of Way Permit Fee $80.00 $80.00 Paid 06/18/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/18/2020
8331507-Sewer Connection Fee $360.00 $360.00 Paid 06/18/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 06/18/2020
Water Meter Fee $425.02 $425.02 Paid 06/18/2020
Not Ready Inspection Fee $50.00 $50.00 Paid 01/06/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 01/06/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 01/06/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/10/2020 07/13/2020
Misc
Informational
07/13/2020
-3RD PARTY FOOTING SIGNED & SEALED BY DAVID AINSWORTH - - COMMENTS: UFER RO LOCATED SOUTH SIDEWALL ABOUT 13' EAST OF SW CORNER -
Sewer Service Inspection - R Passed 7/23/2020 (1:00) 7/23/2020 07/23/2020
Water Service Inspection - R Passed 7/23/2020 (1:00) 7/23/2020 07/23/2020
Underslab Plumbing Inspection - Residential Passed 7/24/2020 7/24/2020 07/24/2020
All Rough Inspection - Residential Failed 10/20/2020 10/20/2020 10/20/2020
Misc
Corrective Action Required
10/20/2020
-Service entrance conductor bending radius exceeds allowable -Seal holesaw cut in exterior sheathing -Receptacle required within 25’ of exterior HVAC equipment -Ensure all exterior flashing tape is installed and not damaged -At wood frame exterior doors horizontal blocking shall be placed between studs at the door lock height for 3 stud spaces or equivalent bracing on each side of the door opening -Interior tension straps at portal opening -Anchor bolt required within 12 inches of plate splices -Garage receptacle outlets required to be 20A circuit -Re-identify white insulated conductors used as current carrying conductors at both termination points -Midpoint strap for all vertical 2” and smaller DWV piping -Protect NM conductors minimum 6” AFF at floor penetrations -Complete gas fireplace and vent installation -End joints in top plates shall be offset not less than 24” -Provide attic access -Fireblock concealed space next to main level hallway closet -Proper nail plate protection of water piping for master toilet & laundry -Provide outlet box, master bedroom ceiling -12” oc fastening at stud to stud and abutting studs at intersecting wall corners (at braced wall panels) -Complete gas piping, connect to appliances per manufacturer instructions and pressure test piping -Fasten bathroom exhaust duct to termination -Complete furr outs in basement -Anchor steel columns in basement -Complete fireblocking at basement egress windows -Couldn’t locate water heater circuit in unfinished area
Electrical Service Inspection Failed 10/20/2020
Misc
Corrective Action Required
10/20/2020
-Service entrance conductor bending radius exceeds allowable
Gas Piping Inspection - Residential Failed 10/20/2020
Misc
Corrective Action Required
10/20/2020
-Complete gas piping, connect to appliances per manufacturer instructions and pressure test piping
Erosion Control Inspection Residential Passed 7/24/2020 10/20/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/20/2020
- MAINTAIN SILT FENCE - - PROVIDE GRAVEL FILTER -
Gas Service Inspection - Residential Failed 10/20/2020
Misc
Corrective Action Required
10/20/2020
-Complete gas piping, connect to appliances per manufacturer instructions and provide pressure test of piping
Gas Service Inspection - Residential Failed 10/29/2020 10/29/2020
Misc
Corrective Action Required
10/20/2020
-Install and connect gas piping to appliance (fireplace) per manufacturer instructions and provide pressure test of piping, minimum 10psi for 15 minutes
All Rough Inspection - Residential Failed 11/2/2020 11/2/2020 11/02/2020
Misc
Corrective Action Required
10/20/2020
-Service entrance conductor bending radius exceeds allowable, load side at meter can -Seal holesaw cut in exterior sheathing -Midpoint strap for all vertical 2” and smaller DWV piping -connect gas piping to fireplace per manufacturer instructions and pressure test piping -Complete fireblocking at basement egress window, in bedroom right of bath -Couldn’t locate water heater circuit in unfinished area -WORK DONE SINCE LAST INSPECTION- -Seal penetration in floor at fireplace gas piping -seal bottom plate and exterior penetration for exterior HVAC maintenance receptacle outlet -Provide and make up switchbox master bath -extend ducts to furr down ceilings in basement -Repair damaged fireblock of ceiling furr downs at cut outs for plumbing -Fireblock furr down ceiling, basement main room closet DO NOT INSULATE DO NOT ROCK REINSPECTION REQUIRED
Erosion Control Inspection Residential Failed 11/06/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/24/2020
-Deficient erosion control, methods require continuous maintenance. Issue must be resolved within two days. -Post building address -No further inspections until issues are resolved
Gas Piping Inspection - Residential Failed 11/11/2020 11/11/2020 11/11/2020
Misc
Corrective Action Required
10/20/2020
-Complete gas piping, connect to appliances per manufacturer instructions and pressure test piping
Misc
Corrective Action Required
11/11/2020
11/11/2020- Inspection denied due to lack of compliance with 11/06/2020 Erosion Control inspection report
Gas Service Inspection - Residential Failed 11/11/2020 11/11/2020 11/11/2020
Misc
Corrective Action Required
10/29/2020
-Install and connect gas piping to appliance (fireplace) per manufacturer instructions and provide pressure test of piping, minimum 10psi for 15 minutes
Misc
Corrective Action Required
11/11/2020
11/11/2020- Inspection denied due to lack of compliance with 11/06/2020 Erosion Control inspection report
Erosion Control Inspection Residential Failed 12/11/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/06/2020
-Deficient erosion control, methods require continuous maintenance. Issue must be resolved within two days. -Post building address -No further inspections until issues are resolved
All Rough Inspection - Residential Not Ready 12/11/2020 12/11/2020 12/11/2020
Misc
Corrective Action Required
11/02/2020
-Service entrance conductor bending radius exceeds allowable, load side at meter can -Seal holesaw cut in exterior sheathing -Midpoint strap for all vertical 2” and smaller DWV piping -connect gas piping to fireplace per manufacturer instructions and pressure test piping -Complete fireblocking at basement egress window, in bedroom right of bath -Couldn’t locate water heater circuit in unfinished area -WORK DONE SINCE LAST INSPECTION- -Seal penetration in floor at fireplace gas piping -seal bottom plate and exterior penetration for exterior HVAC maintenance receptacle outlet -Provide and make up switchbox master bath -extend ducts to furr down ceilings in basement -Repair damaged fireblock of ceiling furr downs at cut outs for plumbing -Fireblock furr down ceiling, basement main room closet DO NOT INSULATE DO NOT ROCK REINSPECTION REQUIRED
Misc
Corrective Action Required
12/11/2020
Inspection denied due to lack of compliance with erosion control inspection report dated 11/6/2020
All Rough Inspection - Residential Not Ready 12/17/2020 12/17/2020 12/17/2020
Misc
Corrective Action Required
12/11/2020
-Service entrance conductor bending radius exceeds allowable, load side at meter enclosure. The radius of the curve of the inner edge of any bend shall not be less than five times the diameter of the cable -Midpoint strap for all vertical 2” and smaller DWV piping, Basement -pressure test gas piping -Complete fireblocking at basement egress window, in bedroom right of bath -Couldn’t locate water heater circuit in unfinished area -Seal penetration in floor at fireplace gas piping -seal bottom plate penetration for exterior HVAC maintenance receptacle outlet, Master bedroom -Repair damaged fireblock of ceiling furr downs at cut outs for plumbing, Basement bedroom left of bathroom LOCATIONS WHERE FIREBLOCK IS REQUIRED ARE MARKED WITH FB AND AN ARROW POINTING TO THE LOCATION
Misc
Resolved
12/17/2020
Inspection denied due to lack of compliance with erosion control inspection report dated 11/6/2020
Erosion Control Inspection Residential Passed 12/17/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
12/17/2020
-Deficient erosion control, methods require continuous maintenance. Issue must be resolved within two days. -Post building address -No further inspections until issues are resolved
Electrical Service Inspection Failed 12/17/2020
Misc
Corrective Action Required
10/20/2020
-Service entrance conductor bending radius exceeds allowable, load side meter can enclosure
Gas Piping Inspection - Residential Failed 12/17/2020
Misc
Corrective Action Required
11/11/2020
pressure test piping
Misc
Resolved
12/17/2020
11/11/2020- Inspection denied due to lack of compliance with 11/06/2020 Erosion Control inspection report
Gas Service Inspection - Residential Failed 12/17/2020
Misc
Corrective Action Required
11/11/2020
provide pressure test of piping, minimum 10psi for 15 minutes
Misc
Resolved
12/17/2020
11/11/2020- Inspection denied due to lack of compliance with 11/06/2020 Erosion Control inspection report
All Rough Inspection - Residential Passed 1/4/2021 1/4/2021 01/04/2021
Misc
Resolved
01/04/2021
-Service entrance conductor bending radius exceeds allowable, load side at meter enclosure. The radius of the curve of the inner edge of any bend shall not be less than five times the diameter of the cable -Midpoint strap for all vertical 2” and smaller DWV piping, Basement -pressure test gas piping -Complete fireblocking at basement egress window, in bedroom right of bath -Couldn’t locate water heater circuit in unfinished area -Seal penetration in floor at fireplace gas piping -seal bottom plate penetration for exterior HVAC maintenance receptacle outlet, Master bedroom -Repair damaged fireblock of ceiling furr downs at cut outs for plumbing, Basement bedroom left of bathroom LOCATIONS WHERE FIREBLOCK IS REQUIRED ARE MARKED WITH FB AND AN ARROW POINTING TO THE LOCATION
Electrical Service Inspection Failed 01/04/2021
Misc
Corrective Action Required
12/17/2020
-Service entrance conductor bending radius exceeds allowable, load side at meter enclosure. The radius of the curve of the inner edge of any bend shall not be less than five times the diameter of the cable
Gas Piping Inspection - Residential Failed 01/04/2021
Misc
Corrective Action Required
12/17/2020
pressure test piping
Gas Service Inspection - Residential Failed 01/04/2021
Misc
Corrective Action Required
12/17/2020
provide pressure test of piping, minimum 10psi for 15 minutes
Gas Service Inspection - Residential Not Ready 1/6/2021 1/6/2021 01/06/2021
Misc
Corrective Action Required
01/04/2021
provide pressure test of piping, minimum 10psi for 15 minutes
Gas Service Inspection - Residential Passed 1/7/2021 1/7/2021 01/07/2021
Misc
Resolved
01/07/2021
provide pressure test of piping, minimum 10psi for 15 minutes
Gas Piping Inspection - Residential Passed 01/07/2021
Misc
Resolved
01/07/2021
pressure test piping
Erosion Control Inspection Residential Failed 02/04/2021
Misc
Corrective Action Required
02/04/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -remove debris from street & curb/gutter -no further inspections until issues are resolved
Miscellaneous Inspection Failed 02/04/2021
Misc
Corrective Action Required
02/04/2021
Post site address, no further inspections until resolved
Electrical Service Inspection Passed 2/4/2021 2/4/2021 02/04/2021
Misc
Resolved
02/04/2021
-Service entrance conductor bending radius exceeds allowable, load side at meter enclosure. The radius of the curve of the inner edge of any bend shall not be less than five times the diameter of the cable
Piers/Caissons Inspection - Residential Passed 03/18/2021
Sidewalk Inspection Partial 3/22/2021 (Ready Now) 3/22/2021 03/22/2021
Misc
Informational
03/22/2021
Forms were placed and aggregate was present. They were getting ready to compact the soft areas. Also need to remove drain hose that was placed under the sidewalk. RP 3-22-21
Sidewalk Inspection Passed 3/26/2021 3/26/2021 03/29/2021
Misc
Informational
03/22/2021
Forms were placed and aggregate was present. They were getting ready to compact the soft areas. Also need to remove drain hose that was placed under the sidewalk. RP 3-22-21
Misc
Informational
03/29/2021
Finished sidewalk meets LS and ADA specs. RP 3-29-21
Miscellaneous Inspection Passed 05/25/2021
Misc
Resolved
05/25/2021
Post site address, no further inspections until resolved
Occupancy Inspection - Codes Residential Failed 5/25/2021 5/25/2021 05/25/2021
Misc
Corrective Action Required
05/25/2021
-Maintenance of erosion control Methods is Required until sod is in place -final grade & sod -Irrigation permit required -No building address. Minimum 4 inch height, half-inch stroke, on contrasting background and in illuminated area -Paint exterior gas piping -Complete electrical installation of master bedroom, ceiling fan installation -Secure water sprinkler piping in basement unfinished area -Self closing & self latching garage/dwelling separation door -Provide properly sized OCPD, condensing unit
Occupancy Inspection - Codes Residential Temporary C of O 5/27/2021 5/27/2021 05/27/2021
Misc
Corrective Action Required
05/25/2021
-Maintenance of erosion control Methods is Required until sod is in place -final grade & sod -Irrigation permit required TCO VALID THROUGH JUNE 27, 2021
Occupancy Inspection - Codes Residential Temporary C of O 6/28/2021 6/28/2021 06/28/2021
Misc
Corrective Action Required
05/27/2021
-Maintenance of erosion control Methods is Required until sod is in place -final grade & sod -Irrigation permit required TCO EXTENSION VALID THROUGH JULY 27, 2021
Occupancy Inspection - Codes Residential Full C of O 12/20/2021 12/20/2021 12/20/2021
Misc
Corrective Action Required
06/28/2021
-Maintenance of erosion control Methods is Required until sod is in place -final grade & sod -Irrigation permit required TCO EXTENSION VALID THROUGH JULY 27, 2021
Documents & Images
Date Uploaded File Type Document Name
06/09/2020 AVERY PLOT PLAN CITY
06/09/2020 AVERY ENGINEERED CONSTRUCTION DOCS
06/09/2020 Application Form Lot 89 Permit App
06/18/2020 AVERY ENGINEERED CONSTRUCTION DOCS 1021 Armie
06/18/2020 Letter Codes Residential Plan Review
06/18/2020 Plans APPROVED HOUSE PLANS
06/18/2020 Excise Tax
06/18/2020 Approved Elevations
06/18/2020 Plot Plan APPROVED PLOT PLAN
06/18/2020 Receipt Receipt for transaction:2020-003291
06/18/2020 Letter DS Building Permit
07/11/2020 M L Crose 1021 SW Armie St LSMO Pergola Park Lot 89 Cardinal Crest P 2020-1545 3rd Party Footing Inspection Report 7-10-20
07/13/2020 Letter INSPECTION SUMMARY
07/22/2020 DW 1st Floor I-Joist 1021 SW Armie
07/22/2020 1021 SW Armie - ROOF SEALS
07/22/2020 DW Roof Truss Layout 1021 SW Armie
07/23/2020 Letter INSPECTION SUMMARY
07/23/2020 Letter INSPECTION SUMMARY
07/24/2020 Letter INSPECTION SUMMARY
07/24/2020 Letter INSPECTION SUMMARY
08/10/2020 Engineer Report/Study Final_2020.08.05_GSlab_LSMO_Cardinal Crest
10/20/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter INSPECTION SUMMARY
11/02/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter INSPECTION SUMMARY
12/17/2020 Letter INSPECTION SUMMARY
12/17/2020 Letter INSPECTION SUMMARY
12/17/2020 Letter INSPECTION SUMMARY
12/17/2020 Letter INSPECTION SUMMARY
12/17/2020 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
01/06/2021 Letter INSPECTION SUMMARY
01/06/2021 Receipt Receipt for transaction:2021-000066
01/07/2021 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
03/17/2021 Final_2021_03_08_DPier_LSMO_Cardinal Crest
03/18/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
05/25/2021 Letter INSPECTION SUMMARY
05/25/2021 Letter INSPECTION SUMMARY
05/27/2021 Letter Codes Temporary Certificate of Occupancy
05/27/2021 Letter Codes Temporary Certificate of Occupancy
06/28/2021 Letter Codes Temporary Certificate of Occupancy
12/20/2021 Letter Codes Final Certificate of Occupancy
12/20/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home