Permit Application Status

PRRES20201223


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201223
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW SINGLE FAMILY PARTIALLY FINISHED BASEMENT COVERED DECK
05/13/2020
05/19/2020
12/11/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/19/2020 05/18/2020
Steve Conrick
Residential Plan Review Approved 05/19/2020 05/18/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $872.64 $872.64 Paid 05/19/2020
Right of Way Permit Fee $80.00 $80.00 Paid 05/19/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/19/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 05/19/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 05/19/2020
Water Meter Fee $425.02 $425.02 Paid 05/19/2020
Not Ready Inspection Fee $50.00 $50.00 Paid 11/25/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 6/10/2020 6/10/2020 06/10/2020
Sewer Service Inspection - R Passed 6/15/2020 (9:00) 6/15/2020 06/15/2020
Water Service Inspection - R Passed 6/16/2020 (10:30) 6/16/2020 06/16/2020
All Rough Inspection - Residential Not Ready 8/19/2020 8/19/2020 08/19/2020
Misc
Corrective Action Required
08/19/2020
NO INSPECTION PERFORMED - NO CITY APPROVED PLANS OR CITY APPROVED TRUSS PLANS ON SITE
Electrical Service Inspection Passed 8/20/2020 8/20/2020 08/20/2020
Gas Piping Inspection - Residential Failed 8/20/2020 8/20/2020 08/20/2020
Misc
Corrective Action Required
08/20/2020
- Secure gas flex line at fireplace - Support steel gas line per code
Gas Service Inspection - Residential Failed 8/20/2020 8/20/2020 08/20/2020
Misc
Corrective Action Required
08/20/2020
- Secure flex gas line at fireplace - Support steel gas line per code - Gas pressure at 8 psi, must maintain 10 psi for 15 minutes minimum
All Rough Inspection - Residential Failed 8/20/2020 8/20/2020 08/20/2020
Misc
Corrective Action Required
08/19/2020
- Structural straps at top plate bores/notches 50% and greater on exterior walls and interior bearing walls required - Secure all DWV 2” or less at mid point - Secure gas flex line at fireplace - Security blocking at basement door - Support steel gas line per code - Seal gaps at top plate Fireblock basement bedroom - Ceiling 2x4 laid flat 3” or more at furred downs in basement need to be connected and supported by floor joists to support the ceiling load - Support DWV 48” o.c., traps not considered support - Truss bracing per plans - EC#2 per plans - Protection plate required at DWV top plate wet bar basement - Tighten all anchor bolts at sill plate in basement - Deck ledger lag bolt connection on center spacing of fasteners per code - Gas pressure at 8 psi, must maintain 10 psi minimum for 15 minutes
Gas Piping Inspection - Residential Passed 8/26/2020 8/26/2020 08/26/2020
Misc
Resolved
08/26/2020
Gas Service Inspection - Residential Passed 8/26/2020 8/26/2020 08/26/2020
Misc
Resolved
08/26/2020
All Rough Inspection - Residential Failed 8/26/2020 8/26/2020 08/26/2020
Misc
Corrective Action Required
08/20/2020
- Security blocking at basement door OK to Insulate
All Rough Inspection - Residential Passed 8/28/2020 8/28/2020 08/27/2020
Misc
Resolved
08/27/2020
Driveway Inspection Passed 10/1/2020 (P.M.) 10/1/2020 10/01/2020
Misc
Informational
10/01/2020
On Thursday, 10-01-2020. I performed a driveway inspection and passed inspection to pour approach.
Sidewalk Inspection Passed 10/01/2020
Misc
Informational
10/01/2020
On Thursday, 10-01-2020. I performed a sidewalk inspection and passed sidewalk to installed.
Footing Inspection - Residential Passed 11/06/2020
Piers/Caissons Inspection - Residential Passed 11/06/2020
Occupancy Inspection - Codes Residential Failed 11/6/2020 11/6/2020 11/06/2020
Misc
Corrective Action Required
11/06/2020
-Complete final grade and sod -Post permanent address -Resolve outstanding inspection fee(s) -remove all paint covers from smokes -install non combustible attic access cover in garage -Install kitchen faucet -Entry AFCI breaker not tripping when test button pressed -security screws, provide (2) 3” screws each exterior hinge and strike plate -Install AC compressor or remove electrical whip -Seal all penetrations in siding -Nail stacked rim joists together at deck -Place splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation
Occupancy Inspection - Codes Residential Temporary C of O 12/1/2020 12/1/2020 12/01/2020
Misc
Corrective Action Required
11/06/2020
-Complete final grade and sod -Obtain lawn irrigation system permit OK FOR TCO
Erosion Control Inspection Residential Passed 12/11/2020
Plot Plan Inspection Passed 12/11/2020
Occupancy Inspection - Codes Residential Full C of O 12/11/2020 12/11/2020 12/11/2020
Misc
Resolved
12/11/2020
-Complete final grade and sod -Obtain lawn irrigation system permit OK FOR TCO
Documents & Images
Date Uploaded File Type Document Name
05/13/2020 62 HAWTHORNE RIDGE ROOF LAYOUT- signed
05/13/2020 400157
05/13/2020 LOT 62 FINAL
05/13/2020 H4 #62 - Charlotte - Mediterranean - Sheets- signed
05/13/2020 H4 #62 - PERMIT APP
05/15/2020 APPROVED 400157
05/15/2020 APPROVED 62 HAWTHORNE RIDGE ROOF LAYOUT- signed
05/18/2020 APPROVED H4 #62 - Charlotte - Mediterranean - Sheets- signed
05/18/2020 APPROVED LOT 62 FINAL
05/19/2020 Receipt Receipt for transaction:2020-002224
05/19/2020 Letter DS Building Permit
05/21/2020 Letter Lot 62 Hawthorne Ridge -Subgrade Inspection
05/22/2020 Engineer Report/Study Lot 62 Hawthorne Ridge -Footing Inspection
05/28/2020 Letter Lot 62 Hawthorne Ridge -Wall Inspection
06/10/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/16/2020 Letter INSPECTION SUMMARY
08/19/2020 Letter INSPECTION SUMMARY
08/20/2020 Letter INSPECTION SUMMARY
08/20/2020 Letter INSPECTION SUMMARY
08/20/2020 Letter INSPECTION SUMMARY
08/20/2020 Letter INSPECTION SUMMARY
08/26/2020 Letter INSPECTION SUMMARY
08/26/2020 Letter INSPECTION SUMMARY
08/26/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter INSPECTION SUMMARY
11/25/2020 Receipt Receipt for transaction: 2020-007734
12/01/2020 Letter Codes Temporary Certificate of Occupancy
12/11/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter Codes Final Certificate of Occupancy
12/11/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: