Permit Application Status

PRRES20200246


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200246
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY DEFERRED ENGINEERED FLOOR SYSTEM PARTIALLY FINISHED BASEMENT COVERED DECK
01/31/2020
02/06/2020
12/01/2020
Locations
Contacts
GALE HOMES II INC, Address:400 SW LONGVIEW BLVD, Unit 109, Phone:(816) 761-9292  
MFAULKNER@GALECOMMUNITIES.COM  
MC ELECTRICAL SERVICES INC, Address:1502 N VANSANT RD, Phone:(816) 392-3970  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/04/2020 02/04/2020
Steve Conrick
Residential Plan Review Approved 02/04/2020 02/04/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,518.10 $1,518.10 Paid 02/06/2020
Right of Way Permit Fee $80.00 $80.00 Paid 02/06/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/06/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 02/06/2020
Water Meter Fee $425.02 $425.02 Paid 02/06/2020
8331507-Sewer Connection Fee $510.00 $510.00 Paid 02/06/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/21/2020 2/21/2020 02/21/2020
Underslab Plumbing Inspection - Residential Passed 3/27/2020 3/27/2020 03/27/2020
Sewer Service Inspection - R Passed 4/10/2020 4/10/2020 at 2:36 PM 04/10/2020
Water Service Inspection - R Partial 4/10/2020 4/10/2020 at 2:35 PM 04/10/2020
Water Service Inspection - R Passed 4/14/2020 4/14/2020 04/14/2020
Gas Piping Inspection - Residential Passed 6/30/2020 6/30/2020 06/30/2020
Gas Service Inspection - Residential Passed 6/30/2020 06/30/2020
Electrical Service Inspection Failed 6/30/2020 6/30/2020 06/30/2020
Misc
Corrective Action Required
06/30/2020
- REMOVE GREEN BONDING SCREW @ SUBPANEL - ( OR PROVIDE MANUFACTURES SPECS )
All Rough Inspection - Residential Failed 6/30/2020 06/30/2020
Misc
Corrective Action Required
06/30/2020
- ADDRESS RAFTERS LANDING ON BLOCKS - - SEAL ALL UPWARD & EXTERFIOR PENETRATIONS - - FIRE BLOCK BASEMENT FURR OUT VERTICAL EVERY 10' & VERTICAL TO HORIZONTAL - - TIGHTEN ANCHOR BOLTS THROUGHOUT - - PROVIDE ANCHOR BOLTS WITHIN 12" OF PLATE BRAKS THROUGHOUT - - ALL ANCHOR BOLTS SHALL BE LOCATED IN MIDDLE THIRD OF THE WIDTH OF PLATE (R403.1.6) - - PROVIDE SOLID SECURITY BLOCKING SIDE GARAGE DOOR - - FIRE BLOCK CHASE NEAR PANTRY - - NAIL JOIST HANGERS ABOVE BASEMENT LANDING - - FOUNDATION PLAN SHOWS W10X22 BEAM AT MEDIA/STORAGE ROOM - - - 3RD PARTY SUSPENDED SLAB INSPECTION ABOVE SAFE ? - - LIST SUBJECT TO CHANGE UPON REVIEW OF CITY STAMPED PLANS & FIRE BLOCKING COMPLETION ) -
Piers/Caissons Inspection - Residential Passed 7/1/2020 07/01/2020
Misc
Informational
07/01/2020
3RD PARTY LETTER SIGNED & SEALED BY CLAYTON HESS ADDRESSING EXCAVATION ORIGINAL SOLID LIMESTONE SHELF AT FROST FOOTING -
All Rough Inspection - Residential Passed 7/2/2020 7/2/2020 07/02/2020
Misc
Resolved
07/02/2020
Electrical Service Inspection Passed 7/2/2020 07/02/2020
Misc
Resolved
07/02/2020
Driveway Inspection Partial 7/2/2020 (A.M.) 7/2/2020 07/02/2020
Misc
Corrective Action Required
07/02/2020
Approach was poured before inspection. Talked with Brian for Bishop Concrete and Zach from Gale Homes about how the inspection process works and to not pour another one before inspection. RP 7-2-20
Driveway Inspection Passed 7/10/2020 7/10/2020 07/09/2020
Misc
Informational
07/02/2020
Approach was poured before inspection. Talked with Brian for Bishop Concrete and Zach from Gale Homes about how the inspection process works and to not pour another one before inspection. RP 7-2-20
Misc
Informational
07/09/2020
Finished driveway meets LS specs. RP 7-9-20
Occupancy Inspection - Codes Residential Failed 11/17/2020 11/17/2020 11/17/2020
Misc
Corrective Action Required
11/17/2020
-Irrigation permit required -Complete downspout installation, Must discharge 36 inches minimum from foundation -Seal penetrations in exterior siding -Conductors in exterior raceway required to be rated for wet location -provide properly sized OCPD for large condensing unit, max 40 -Complete exterior gas piping installation -attic access lid must be tight fitting -3” wood screws at exterior door strikes -garage/dwelling door required to self close and self latch -install exterior door hardware -remove cover from smoke alarm in master & unfinished basement area -missing outlet device in sub panel closet -Complete plumbing installation, basement bath -install outlet plate covers, basement bar -Complete electrical installation, nonmetallic conductor hanging from basement bedroom ceiling -locate grounding connection to concrete encased electrode -install secondary locking device for sliding glass doors
Occupancy Inspection - Codes Residential Full C of O 12/1/2020 12/1/2020 12/01/2020
Misc
Resolved
12/01/2020
Plot Plan Inspection Passed 12/01/2020
Erosion Control Inspection Residential Passed 12/01/2020
Documents & Images
Date Uploaded File Type Document Name
02/06/2020 Receipt Receipt for transaction: 2020-000473
02/06/2020 Letter DS Building Permit
02/11/2020 Plot Plan DOC021020-02102020104052
02/21/2020 Letter INSPECTION SUMMARY
02/24/2020 Engineer Report/Study 208 NW Carson Dr_Lot 1453 Winterset Valley Final_2020.02.18_SiteObv_LSMO_Gael Homes II
03/27/2020 Letter INSPECTION SUMMARY
04/10/2020 Letter INSPECTION SUMMARY
04/10/2020 Letter INSPECTION SUMMARY
04/14/2020 Letter INSPECTION SUMMARY
06/30/2020 Letter INSPECTION SUMMARY
06/30/2020 Letter INSPECTION SUMMARY
06/30/2020 Letter INSPECTION SUMMARY
06/30/2020 Letter INSPECTION SUMMARY
07/02/2020 Letter INSPECTION SUMMARY
07/02/2020 Letter INSPECTION SUMMARY
07/02/2020 Letter INSPECTION SUMMARY
07/09/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
11/17/2020 Letter INSPECTION SUMMARY
12/01/2020 Letter Codes Final Certificate of Occupancy
12/01/2020 Letter Field Certificate of Occupancy
12/01/2020 Letter INSPECTION SUMMARY
12/01/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents