Permit Application Status

PRRES20200127


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200127
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSS - COVERED PATIO
01/16/2020
01/23/2020
10/29/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/21/2020 01/22/2020
Dylan Eppert
Planning Review (RES) Approved 01/23/2020 01/22/2020
Dylan Eppert
Residential Plan Review Approved 01/21/2020 01/21/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $964.60 $964.60 Paid 01/23/2020
8331507-Sewer Connection Fee $360.00 $360.00 Paid 01/23/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 01/23/2020
Water Meter Fee $425.02 $425.02 Paid 01/23/2020
Right of Way Permit Fee $80.00 $80.00 Paid 01/23/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/23/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 2/27/2020 (10:45) 2/27/2020 02/27/2020
Water Service Inspection - R Passed 2/28/2020 02/28/2020
Underslab Plumbing Inspection - Residential Passed 3/24/2020 3/24/2020 03/24/2020
Electrical Service Inspection Passed 7/13/2020 7/13/2020 07/13/2020
Gas Piping Inspection - Residential Passed 7/13/2020 7/13/2020 07/13/2020
Gas Service Inspection - Residential Passed 7/13/2020 7/13/2020 07/13/2020
All Rough Inspection - Residential Failed 7/13/2020 7/13/2020 07/13/2020
Misc
Corrective Action Required
07/13/2020
- Garage PFH per plans - Tighten all anchor bolts in garage - Protect and secure pex at showers per manufacturer listing - Metallic tape at bath fan exhaust connection - Support DWV every 48” o.c. - Truss hangers per plan in garage
All Rough Inspection - Residential Failed 7/15/2020 7/15/2020 07/15/2020
Misc
Corrective Action Required
07/13/2020
- Metallic tape at bath fan exhaust connection
All Rough Inspection - Residential Passed 7/17/2020 7/17/2020 07/17/2020
Misc
Resolved
07/17/2020
Driveway Inspection Passed 8/3/2020 8/3/2020 08/04/2020
Misc
Informational
08/04/2020
On Monday, 8-03-2020. A drive approach inspection was performed and passed for concrete installation.
Erosion Control Inspection Residential Failed 08/19/2020
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
08/19/2020
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Occupancy Inspection - Codes Residential Failed 9/15/2020 9/15/2020 09/15/2020
Misc
Corrective Action Required
09/15/2020
-Final grade per approved plot plan and sod -Provide third-party footing inspection report -Provide minimum 36” splash blocks at downspouts -Sump to discharge minimum 36” from foundation -provide 100w flood light type, rear of structure -Remove trash and construction debris -Missing receptacle devices -Missing device plate covers -Remove paint covers from smoke and carbon monoxide alarms -Label all dedicated circuits as non-GFCI protected In garage and unfinished basement -Provide maximum 30A OCPD for condensing unit -Label bathroom group vent for future basement restroom OCCUPANCY NOT APPROVED RE-INSPECTION REQUIRED
Footing Inspection - Residential Passed 9/24/2020 9/24/2020 09/24/2020
Occupancy Inspection - Codes Residential Failed 9/24/2020 9/24/2020 09/24/2020
Misc
Corrective Action Required
09/15/2020
-Final grade per approved plot plan and sod -Remove paint covers from smoke and carbon monoxide alarms - master bed, basement -Label all dedicated receptacles as non-GFCI protected In garage and unfinished basement
Occupancy Inspection - Codes Residential Temporary C of O 10/1/2020 10/1/2020 10/01/2020
Misc
Corrective Action Required
09/24/2020
-Final grade per approved plot plan and sod OK for TCO
Plot Plan Inspection Passed 10/23/2020 10/23/2020
Occupancy Inspection - Codes Residential Failed 10/23/2020 10/23/2020 10/23/2020
Misc
Corrective Action Required
10/01/2020
- PROVIDE SUMP DISCHARGE 36" FROM FOUNDATION - - NO COVERED PATIO PIER INSPECTION ON RECORD - - SUBMIT BACKFLOW CERTIFICATION LAWN IRRIGATION PERMIT 20203178 - - - PROVIDE 6" CLEARANCE WOOD SIDING TO SOD - OK for TCO EXPIRES 10/29/2020
Piers/Caissons Inspection - Residential Passed 10/29/2020
Occupancy Inspection - Codes Residential Full C of O 10/29/2020 10/29/2020 10/29/2020
Misc
Resolved
10/29/2020
Documents & Images
Date Uploaded File Type Document Name
01/23/2020 Receipt Receipt for transaction: 2020-000262
01/23/2020 Letter DS Building Permit
01/27/2020 Plot Plan DOC012420-01242020164259
02/27/2020 Letter INSPECTION SUMMARY
02/28/2020 Letter INSPECTION SUMMARY
03/24/2020 Letter INSPECTION SUMMARY
07/13/2020 Letter INSPECTION SUMMARY
07/13/2020 Letter INSPECTION SUMMARY
07/13/2020 Letter INSPECTION SUMMARY
07/13/2020 Letter INSPECTION SUMMARY
07/15/2020 Letter INSPECTION SUMMARY
07/17/2020 Letter INSPECTION SUMMARY
08/19/2020 Letter INSPECTION SUMMARY
09/15/2020 Letter INSPECTION SUMMARY
09/15/2020 Letter INSPECTION SUMMARY
09/16/2020 67 HR
09/24/2020 Letter INSPECTION SUMMARY
09/24/2020 Letter INSPECTION SUMMARY
10/01/2020 Letter Codes Temporary Certificate of Occupancy
10/23/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter INSPECTION SUMMARY
10/28/2020 H4 67 Patio Pier
10/29/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter Field Certificate of Occupancy
10/29/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home